ibx instruments ULTR Ultrasonic Bath with Heater and Timer User Manual
- August 30, 2024
- IbX instruments
Table of Contents
ULTR Ultrasonic Bath with Heater and Timer
“`html
Specifications:
-
Product Name: ULTR Ultrasonic Bath with Heater and Timer
-
Applications: Electronic factory, Car workshops, Industrial and
mining area, Laboratories, Hospitals, Dental clinics, Watch shop,
Optical shops, Jewelry shops, Mobile phone repair shops, and
household use. -
Heater Caution: Forbidden when using flammable liquids such as
alcohol or solvent cleaners
Product Usage Instructions:
Operation Procedure:
-
Check for loose parts before starting the equipment.
-
Place the unit on a stable, flat surface in a dry and cool
environment. -
Add detergent to the tank based on the size and quantity of
washing objects. -
Ensure correct power and switch connection before starting the
equipment. -
To start ultrasonic cleaning:
-
Rotate clockwise to choose the desired time (up to 30
minutes). -
Indicator light and sound will confirm ultrasonic
operation.
-
-
If heating is needed:
- Adjust the temperature between 40-60 degrees by starting the
heating function.
- Adjust the temperature between 40-60 degrees by starting the
-
To stop cleaning:
- Press OFF once to stop ultrasonic operation.
- Turn the heating control knob to OFF.
- Switch off the unit, disconnect power, empty the liquid, and
clean the tank for next use.
Operation Instructions (Digital Models):
-
Timer Setting: Default setting is 5:00. Press
TIME+ to adjust time up or down by 1 minute. -
SEMIWAVE: Activate during ultrasonic operation
for half wave form; press again to turn off. -
DEGAS: Activate during ultrasonic operation
for degassing; press again to turn off. (Effective only when
ultrasonic is working) -
Automatic Operation: Set time and temperature,
press ON/OFF to start automatic operation; press again to stop.
Disconnect power after use.
Maintenance:
If encountering issues like no ultrasonic, time control failure,
no heating, temperature control failure, or ineffective cleaning,
refer to the user manual for possible causes and solutions related
to power supply, fuse, cable, transducer, PCB board, timer knob,
heater power switch, fuse burnout, heating pad issues, or digital
display problems.
FAQ:
Q: Can I use flammable liquids with the heater
function?
A: No, using flammable liquids like alcohol
with the heater function is forbidden to prevent hazards.
“`
ULTR Ultrasonic bath with heater and timer
Please read the User Manual carefully before use and follow all operating and
safety instructions!
User manual
english
User Manual
ULTR Ultrasonic bath with heater and timer Preface
Users should read this Manual carefully, follow the instructions and
procedures, and beware of all the cautions when using this instrument. Service
When help is needed, you can always contact the Service Department of
manufacturer for technical support: www.labbox.com / e-mail: info@labbox.com
Please provide the customer care representative with the following
information: · Serial number · Description of problem · Your contact
information Warranty This instrument is warranted to be free from defects in
materials and workmanship under normal use and service, for a period of 24
months from the date of invoice. The warranty is extended only to the original
purchaser. It shall not apply to any product or parts which have been damaged
on account of improper installation, improper connections, misuse, accident or
abnormal conditions of operation. For claim under the warranty please contact
your supplier.
2
Applications: Electronic factory, Car workshops, Industrial and mining area,
Laboratories, Hospitals, Dental clinics, Watch shop, Optical shops, Jewelry
shops, Mobile phone repair shops, and household use.
CAUTIONS
Thank you for purchasing the ultrasonic cleaner. Please read the instruction
manual carefully before operation to avoid damage to the machine or any danger
to personal safety.
· Ensure the power supply is within the rated range before connecting the
power cable. Refitting is strictly prohibited! Attention that the control
panel will be eroded by organic solution, strong acid and strong alkali.
· Ensure the earth wiring is well connected before starting. · Ensure the
power key or knob is on the `OFF’ place before starting. · Do not operate if
the tank is empty, or ultrasonic generator will be damaged If heating is
needed, the
water level should not be less than 2/3 · Please close the lid to reduce noise
and be cautious of water and steam to avoid burns when opening the
lid · Do not relocate the machine when fluid in the tank in case of overflow.
· Suggest using water-soluble liquid for bench top ultrasonic cleaners. Strong
acid or flammability cleaner
is forbidden. · Do not use the machine in severe environment:
o The place where temperature changes fiercely. o The place where humidity is
too high and is easy to produce dew. o The place where vibration or impact is
strong. o The place where exists corrosive gas or dust. o The place where
water, oil or chemicals splash. o The place where is filled with explosive and
flammable gas. · Shorten the daily working time. Suggestion is to stop for a
few minutes for heat dissipation after working over 30 minutes.
Heater is forbidden when using flammable liquid(such as alcohol, solvent
cleaner etc.) to clean objects.
3
PRODUCT PRESENTATION
4
OPERATION PROCEDURE
Before starting the equipment, check the machine to see if there is loosen
parts. Keep the unit on a stable and flat working platform in dry and cool
environment. According to the size and quantity of washing objects, add little
bit detergent in the tank which can help improve the cleaning effect. (Empty
tank working is forbidden!) Ensure correct power and switch connect before
starting the equipment.
· Operation Instructions: (Mechanical models)
o Start (ULTRASONIC), clockwise rotate to choose the time you required between
O30 min. When the indicator light is on and make “ZIZI” sound, it shows
ultrasonic operation work OK.
o If need heating, start(HEATING) to adjust required temperature, normally 40
60 .(Heating is optional upon needs).
o To stop cleaning. 1. Press OFF once, the ultrasonic should stop running, the
indicator light will also be off. 2. Rotate the heating control knob to “OFF”
the indicator light will also be off. 3. Then switch off the unit and
disconnect the power. 4. Empty out the liquid and clean the tank and the unit
with clean cloth for next use.
o Operation Instructions: (Digital models)
o Timer setting: When power is connected, the default setting is “5:00 ”
.Press TIME+ once will increase time by 1 min; Press TIME+ once will decrease
time by 1 min.( Free choice and digital countdown control).
o Temperature setting: (heating is optional upon needs):When power is
connected, the default setting is “50” and Actual is room temp, press TEMP+
once, will increase temperature by 1; Press TEMP- once, will decrease
temperature by 1. If the setting temperature is lower than the actual tank
temperature, the operation will stop automatically. When the temperature rises
to the setting temperature, the indicating light goes off. When ultrasonic
work, two temperature screen shows set temperature and actual temperature has
been reached.
o SEMIWAVE: Please open this function when ultrasonic is working, and it will
be working by half wave form. Press this SEMIWAVE button again,then it will be
turned off.
o DEGAS Please open this function when ultrasonic is working, that is open 10
seconds, stop 5 seconds. Press DEGAS button again, then it will be turned off.
SEMIWAVE & DEGAS function just only effective when ultrasonic is working)
o After set the time and temperature, press ON/OFF once, the equipment will
work automatically. Press ON/OFF again, the work process will stop. Then
switch off the unit and disconnect the power supply, empty out the liquid and
clean the tank and the unit with clean cloth for next use.
· Adjusting power: o The function is only available for models with adjustable
power! Rotate SLOWLY the power knob clock-wise to increase the power from 40%
to 100%, and counter-clockwise SLOWLY is to decrease sonic power.
5
MAINTENANCE
The unit must be opened by authorized specialized person only for maintenance
and care of it. · Clean the contaminant in the tank frequently. · Trouble
clearing:
Problem No ultrasonic
Time control failure No heating
Temperature control failure Not well cleaning
Possible Causes
Solutions
Remarks
A. Power supply not connected. B. Fuse broken. C. Cable short circuit. D.
Transducer short circuit. E.PCB Board broken. F. Other reasons
ATimer knob out of control BTimer failure COther reasons
AHeater power switch bad linkage B.Fuse burn out C Heating pad burn out
DDigital display board out of control E Other reasons
AThermostat loosen BThermostat tube broken C Digital display out of control D
Other reasons
A Not strong ultrasonic cleaning B Too high too low liquid surface C Too high
too low temperature
A. Check and plug pow switch. BCheck the fitted power supply and change the same specification fuse. C. Connect fitted cable or replace a new DInquiry our after-service engineer ECheck the broken part and change it. FInquiry our after-service engineer. ALoosen or tighten the screw. BReplace timer or digital panel. CInquiry our after service engineer. ACheck heating plug and connect well, Check outlet line with multimeter: if OK and resistance value is few hundred OHMs.. BChange the same specification fuse. C Replace the bad heating pad if open circuit. D Check the broken part and change it E Inquiry our after service engineer. AFasten the thermostat header BReplace thermostat. CCheck the broken part and change it. DInquiry our after service engineer. A Connect ultrasonic button and adjust. B Adjust liquid into the best surface. C Adjust temperature into the most fitted.
Suggestion 50-60
Suggestion 50-60
D Not suitable cleaning liquid
D Stop and switch off power supply, replace suitable liquid
6
Electric leakage
E Other reasons
after the liquid cool down. E Inquiry our after service engineer.
A.Customer side not grounded B.Machine not grounded
A To ensure grounded. B Check if machine earth wire loosen.
APPLICATION
Industry Semi-conductor Electrical& electronic machine
Precision machine Optical device Hardware & machinery parts
Medical instrument Electroplate
Car parts Chemical fiber
The cleaning products and material Clear dirt
Integrated circuit, power tube, silicon Hards, etching oil, stamping oil,
wafer, diode, lead frame, capillary, polishing wax, dust particles, etc
tray, etc.
Tube parts, cathode ray tube, printed Fingerprint, powder, cutting
circuit board,
oil, stamping oil, iron filings,
quartz parts, electronic components, polishing materials, walnut
telephone
powder, polishing wax, resin,
switching equipment, speaker dust, etc
components, power
meter, LCD glass, core iron parts,
computer floppy
disk, video parts hoop parts, head,
photo die mask, etc
Bearing, sewing machine parts, typewriter, textile machine, optical mechanical
device, gas valve, watches, cameras, metal filter element, etc. Glasses, lens,
prism, optical lens, filter lens, glass device, film, optical fiber, etc
Bearing, gear, ball, metal shaft parts, tools, adjustable valve and cylinder
parts, burner, compressors, hydraulic press, gun and ultracentrifuge, city
water faucet, etc Medical instrument, denture, etc
Galvanized partsmold, stamping parts, etc
Piston ring, carburetor, flow meter housing, compressor shell, electrical
components, etc Chemical or artificial fiber nozzle filter protector chemical
fiber texture, etc
Machine cutting oil, iron filings, polishing powder, fingerprint, 011, grease,
dirt, etc.
Plastic, resin, paraffin, finger printing, etc
Cutting oil, iron filings, grease, polishing powder, finger printing and so on
Iron filings, polishing powder, oil, stamping oil, dirt, etc. Polishing scrap
iron, oil, black iron shell, rust, oxidation shell, scrap iron, polishing
powder, stamping oil, dirtetc. Chemical colloid, glue, and other solid
material, dust, etc
7
. 8
www.labbox.com