LUTEC 7621101053 180 Degree 2-Head Motion-Activated Flood Light Instructions
- June 14, 2024
- LUTEC
Table of Contents
LUTEC 7621101053 180 Degree 2-Head Motion-Activated Flood Light
WET LOCATION/EMPLACEMENT
Please read and understand this entire manual before attempting to assemble, operate, or install the product.
WARNING
- Consult a qualified electrician if you are not certain about the installation process. Always install wiring connections in accordance with the local code, ordinances, and the National Electric Code.
- After turning on the switch, temperature of bulb rises gradually. Do not touch bulb with bare hands until bulbs have completely cooled. When changing the bulb, first turn off the power and allow the bulb to completely cool.
- Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- Do not attempt to install this product while it is plugged in.
- Do not connect this light fixture to a dimmer switch or timer.
- This light fixture is designed to fit standard junction boxes as defined by the National Electrical Code.
- After turning on the switch, temperature of bulb rises gradually. Do not touch bulb with bare hands until bulbs have completely cooled. When changing the bulb, first turn off the power and allow the bulb to completely cool.
- The bulb must not exceed the specified wattage.
- To control the floodlight manually, the control must be wired through a switch.
- To avoid water damage and the risk of electrical shock, the motion sensor controls must be facing the ground when installation is complete.
- Do not install motors, transformers, or fluorescent light fixtures on the same circuit as the fixture.
INSTRUCTIONS FOR USE
MODE | TIME Setting | DISTANCE Setting | Description |
---|---|---|---|
TEST | TEST | Any setting | The sensor will detect movement and the light will |
activate regardless of time of day. After movement has stopped or left the
coverage area, the light will remain on for about 5 seconds, then turn off.
SECURITY (DISTANCE)| 1 MIN| Adjust the “DISTANCE” to L, M, or H. In default H
setting, the fixture will detect the max range, approximately 70 ft./| At
dusk, the motion sensor becomes active. Any movement within the coverage area
will cause the light to turn on. After movement has stopped, the light will
remain on for the preset time limit of 1, 3 or 10 minutes, then turn off. The
motion sensor will remain active throughout the night. At dawn, the motion
sensor will deactivate and remain deactivated throughout the day. Movement
will not cause the light to turn on.
3 MIN
10 MIN
NOTE
-
The sensor has a 14 second warm up period before it will detect motion. When turned on, please wait 14 seconds.
-
Manual Override: Force the fixture to override TEST and SECURITY modes so the light will stay on. Turn the light on manually from the wall switch.
In SECURITY mode: with the fixture already in the ON position, flip the wall switch off and then back on in 3 seconds. There are two ways to revert back to the previous mode:- Once again flip the wall switch off, wait for 10 seconds and then back on;
- If you leave the light on, the light will stay on for about 6 hours.