SASWELL SAS908XWHB-7 Thermostat User Manual
- June 10, 2024
- SASWELL
Table of Contents
SASWELL SAS908XWHB-7 Thermostat
Product Information
The SASWELL SAS908XWHB-7(SL) is an electrical device designed for indoor use only. It is a Class II or double insulated electrical appliance, which means it does not require a safety connection to electrical earth (ground). The product is protected against vertically falling water droplets and items of diameter 12.5 mm or more cannot come in and damage it. The product should be delivered to dedicated recycling boxes after use to contribute to the protection of natural resources.
Product Usage Instructions
- Ensure that the product is used indoors only.
- Do not allow items of diameter 12.5mm or more to come in contact with the product to avoid damage.
- The product is protected against vertically falling water droplets.
- After use, deliver the product to dedicated recycling boxes to contribute to the protection of natural resources.
- Read the whole user manual carefully before using the product.
- Follow the default heating schedule of 6 PROG or customize it according to your preference.
- The user manual is protected by copyright and copying it without permission is prohibited.
WIRING
Way Switched Circuit
1 way switching is when a single switch is used to control a single
circuit. Typically a 1 way switch will be used but a 2 way switch can also be
used. To use a 2 way switch on a 1 way circuit use only the Common and L1
terminals.
Way Switched Circuit
2 way switching is when a single circuit is controlled by 2 switches, enabling
the user to control the circuit from 2 locations. A typical Example is below.
Fused Spur Circuit
A Fused Spur is used when it is needed to protect an appliance from
electrical surges.
Double Pole Switch Circuit
Double Pole switches are used to switch both Live and Neutral
simultaneously.
Intermediate Switched Circuit
An intermediate switch allows for multiple switches (2 or more) to be used
on a single circuit, meaning a circuit can be turned on or off from different
locations.
Way Retractive Switch
Retractive switches are used to temporarily make or break a circuit for
when only a momentary connection or disconnection is required.
Flex Outlet Wiring
Flex outlet modules are used to provide a convenient outlet for fixed
appliances.
Indicator Wiring
Indicator modules are used to visually display whether a circuit is live or
not.
After making the connections, screw the switch plate accessory gently to the
back box ensuring no wires become trapped.
Screw the accessory fully home making sure, when done, the plate is not
distorted.
Mains Wiring:
-
‘L’ Live: Coloured Brown or Red
-
‘E’ Earth: Coloured Green/Yellow
-
‘N’ Neutral: Coloured Blue or Black
-
Conductor lengths may be trimmed in certain applications.
-
Decorative accessory plates are not suitable to be mounted onto wet / damp plaster or paint, as this may cause the accessory to tarnish.
-
This range is not suitable for outdoor installation or in areas of high humidity.
-
For cleaning/polishing of products, use only a soft, dry, clean cloth.
Technical Information
Voltage | 240V~ 50Hz |
---|---|
Current Rating | 1 Way, 2Way switches : 20AX Double Pole Switches : 20A Fuse |
Module : 13A
Flex Outlet Module : 20A
Terminal Size| 4.8mm ø
Torque Value| Terminal Screw: 1.2Nm
Cable Size| 3 x 2.5mm2 , 2 x 4mm2 , 1 x 6mm2
Back Box Depth (Min)| 25mm (Mode, Polar, Deco, Deco +)
35mm (Define, Definity)
Operational Temperature| -50 to +450C
Standards| Switch Modules : BSEN60669-1 Fuse Modules : BS1363/4 Indicator
Modules : BS5733 Flex Outlet Module : BS5733
Safety, Installation and Technical Information
Safety Information
Please read the following information carefully before commencing
installation.
Before commencing any electrical work, to prevent the possibility of receiving an electric shock, ensure the mains isolator on the consumer unit/fuse board is in the ‘OFF’ position.
If in any doubt consult a qualified electrician. The accessory plate must be earthed and wired in accordance with the latest IEE Wiring Regulations, BS 7671. Bare earth cables must always be covered with appropriate sleeving and wired to the earth terminal.
Installation Information
Important
If dimmers are being used in the installation it is recommended they are
installed first (See Dimmer Mounting Kit instructions).
If replacing an existing accessory, check the layout of the existing
terminals. When removing the cables from the terminals, note the cable
connections in the terminal to ensure correct wiring of the new accessory.
The mounting box must be of the correct size for the product, metal or plastic. If the back box has four lugs, then the top and bottom lugs will need to be bent back or removed.
Please see Technical Information overleaf for minimum back box depth, range dependant. The cable must be routed through the most suitable entry point of the mounting box, taking note that a suitable protective grommet is recommended should a metal back box be used.
Cables should be prepared to the appropriate lengths (as stated within these instructions) so that the conductor reaches into the terminal, and the earth conductor is the longest. The terminals should be tightened to their appropriate torque value. Do not over-tighten.
CONTACT
Errors & Omissions excluded. Instructions are subject to change without
notice.
Scolmore House | Mariner | Lichfield Road Industrial Estate | Tamworth |
Staffordshire | B79 7UL | United Kingdom
T: +44 (0)1827 63454 | F: +44 (0)1827 63362 | E:
technical@scolmore.com |
www.scolmore.com
References
- Index English - controls.eu
- Sen Controls d.o.o. – Saswell thermostats – Grelci in Saswell termostati za regulacijo ogrevanja
- Sen Controls d.o.o. – Nadzor ogrevanja in tople sanitarne vode v vašem domu
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>