SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks Instruction Manual

June 6, 2024
SECO-LARM

SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks

SECO-LARM E-941SA-
1K2DPSQ Electromagnetic Locks prod

Model Holding Force** Operating Voltage Current Draw
**E-941SA-600DPSQ*** 600-lb (272kg) 12/24 VDC 500mA@12VDC, 250mA@24VDC
**E-941SA-1K2DPSQ*** 1,200-lb (545kg) 12/24 VDC 500mA@12VDC, 250mA@24VDC
E-941SA-600PQ 600-lb (272kg) 12/24 VDC 500mA@12VDC, 250mA@24VDC
E-941SA-1K2PQ 1,200-lb (545kg) 12/24 VDC 500mA@12VDC,

250mA@24VDC
E-941SA-1K2PD | 1,200-lb (545kg)| 12/24 VDC| 500mA@12VDC, 250mA@24VDC

With status LED, bond sensor, and door position sensor †With status LED and bond sensor ‡With status LED, bond sensor, and timer **Holding force has not been verified by UL

  • MOV surge protection
  • Adjustable mounting bracket
  • Complete mounting hardware for typical installations
  • “L” bracket and “Z” brackets available for easy mounting
  • Detachable faceplate
  • 12/24VDC selectable

NOTES:

  • UL294 Indoor use
  • The power for the E-941SA series is to be provided by a Listed (UL294 or UL603) Class 2 Power Supply.
  • The E-941SA series is intended to be used as an access control system accessory which is installed in accordance with the manufacturer’s installation and operation instructions, ANSI/NFPA 70 and the local authority having jurisdiction.
  • The minimum permissible wire size to be used shall not be less than 22AWG

Parts List

  • 1x Electromagnet
  • 2x Steel washers
  • 2x Guide pins
  • 2x Tamper caps
  • 1x Armature plate
  • 1x Rubber washer
  • 1x Door spacer
  • 2x Hex wrenches
  • 2x Short self-tapping screws
  • 4x Long self-tapping screws
  • 2x Hex-head mounting screws
  • 1x Armature plate holder*
  • 1x Armature screw
  • 1x Sexnut bolt
  • 1x Mounting plate
  • 1x Manual

Specifications

Holding Force 600-lb 1,200-lb.
Operating voltage 12/24 VDC
Current draw 12VDC 500mA
24VDC 250mA
Bond sensor SPDT relay, 3A@12VDC
Door position sensor Reed switch, 0.2A@12VDC
Operating temperature 32°~120° F (0°~49° C)
Dimensions Magnet 913/16″x111/16″x1″ (250x43x25 mm)

101/2″x27/16″x19/16″ (267x62x40 mm)
Armature| 71/4″x11/2″x1/2″ (185x38x12 mm)| 71/4″x27/16″x5/8″ (184x62x16 mm)
Destructive attack| Level I
Line Security| Level I
Standby power| Level I
Endurance| Level IV

Overview

SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks
fig1

Installation Applications

  • When mounting the electromagnet, it may be necessary to use a “Z” and “L” bracket, an “L” bracket, a “U” bracket, and/or plate spacers, depending on the location and the type of door and frame.
  • Use the diagram below to help decide whether or not an optional bracket will be necessary for installation.SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig2 SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig3
  • Typical Installation
  • Plate Spacers
  • “L” Bracket
  • “L” Bracket and “Z” bracket
  • “U” Bracket
  • Armature Mounting Plate

Installation Notes

  1. Read this installation manual thoroughly. A clear understanding of the product and this manual will make installation much easier.
  2. The electromagnetic lock is designed for indoor use ONLY.
  3. The most suitable mounting location for the electromagnetic lock may require the use of additional SECO-LARM accessories such as Z-brackets, L-brackets, and/or spacer plates. Please see the diagram on page 3 to decide if a particular application requires any mounting accessories.
  4. Do not run power wires and signal wires in the same conduit as this may cause interference.
  5. Do not install a diode in parallel with the electromagnetic lock as this may cause a delay when releasing the door as well as cause residual magnetism.
  6. The best location to install the electromagnetic lock is on the inside of the door that is being secured with the wiring concealed in the frame to prevent tampering with the unit.
  7. The minimum permissible wire size to be used shall not be less than 22AWG.

Installation

  1. Fold the mounting template along the dotted line to form a 90-degree angle.SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig4
  2. Close the door. Find a mounting location on the door frame near the upper free-moving corner of the door, or as close as possible to the upper corner of the door frame opposite the hinges.SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig5
  3. Use a hammer to lightly tap the two guide pins into the guide pin holes on the armature plate.
  4. Place the template against the door and frame. Mark where the holes are to be drilled.
  5. Drill holes in the frame and the door as shown on the template and in step #6 below. The smaller holes on the door should not go all the way through.
  6. Depending on the type of door being protected, drill holes according to the diagrams below:SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig9
  7. Put a rubber washer between the two metal washers and place them over the armature screw between the armature plate and the armature plate holder. This allows the plate to pivot around the screw to compensate for door misalignment.SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig10
  8. Tighten the armature screw enough so that the armature plate attempt, but loose armature plate can the anti-spin guide pivot slightly. Make sure pins are in the two guide pinholes.SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig11
  9. Screw the two short self-tapping screws through the mounting plate’s slotted holes, but do not over-tighten them. Keeping them loose will allow for adjustment of the plate so that the long edge of the mounting plate and the armature plate are parallel. See the diagram below.SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig12
  10. Once the mounting plate position is correct, use the four long self-tapping screws to permanently mount the mounting plate.
  11. Drill the cable access hole. Run the wiring through the cable access hole in the mounting plate and through the hole in the door frame.
  12. Remove the cover from the front of the electromagnet. Run the power leads through the large cable access hole.
  13. Push the electromagnet against the mounting plate so the electromagnet ends are flush with the ends of the mounting plate. Use the Allen wrench to screw the hex-head mounting screws through the bottom of the electromagnet into the mounting bracket.
  14. Cut the wires so they are long enough to connect with the terminal block. Set the voltage using the selection jumpers based on your input voltage.
  15. Connect the power and other wires according to the wiring diagram on page 7. Test the unit. Then replace the front cover and install the hex-head tamper caps (x2).

NOTES

  • Failure to correctly set the input voltage may cause damage to the lock.
  • Connect switching devices like push-to-exit switches between the power source and the positive terminal on the lock. Connecting switching devices to the negative terminal may cause a delay in unlocking.
  • This should be the very last step after all steps are confirmed, since once the tamper caps are in place, they are very difficult to remove.

Wiring Diagram

SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks
fig19

NOTES

  • Connect switching devices like push-to-exit switches between the power source and the positive terminal of the lock. Connecting them to the negative terminal may cause a delay in unlocking.

Maximum Distance from Power Source For a complete chart, visit www.seco- larm.com
12VDC Minimum Wire Gauge

Wire Length| 25ft| 50ft| 75ft| 100ft| 150ft| 200ft| 250ft| 300ft| 400ft| 500ft| 1,000ft
---|---|---|---|---|---|---|---|---|---|---|---
Wire Gauge@500mA| 20| 18| 18| 18| 16| 14| 14| 12| 10| —| —

24VDC Minimum Wire Gauge

Wire Length| 25ft| 50ft| 75ft| 100ft| 150ft| 200ft| 250ft| 300ft| 400ft| 500ft| 1,000ft
---|---|---|---|---|---|---|---|---|---|---|---
Wire Gauge@250mA| 22| 22| 22| 20| 18| 18| 16| 16| 14| 14| 14

SECO-LARM E-941SA-1K2DPSQ Electromagnetic Locks fig20

*A fail-safe lock unlocks when power is lost so that, in case of an emergency such as a fire in the building, the fail-safe lock will automatically unlock allowing personnel to escape quickly.
NOTE: All field wiring must be within the protected area.

Troubleshooting

Doors lock, but can easily be forced open

|

·         Make sure the electromagnet and armature plates are properly aligned.

·         Make sure the contact surfaces of the electromagnet and armature plates are clean and free from rust.

·         Check the power leads with a meter, and make sure 12VDC or 24VDC is present.

·         Make sure the rubber washer is installed and free from damage.

---|---

Delay in door releasing

| ·         The electromagnet is fitted with a metal oxide varistor to prevent interference, so do not install a second diode.

·         Ensure that the control device is connected between the power source and the positive terminal of the lock

IMPORTANT WARNING: Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause a dangerous electric shock, damage the device, and void the warranty. Users and installers are responsible for ensuring that this product is properly installed and sealed.

IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product comply with all national, state, and local laws and codes. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.

California Proposition 65 Warning: These products may contain chemicals that are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

LIMITED LIFETIME WARRANTY

This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else. For all other countries, the warranty is 1 (one) year.

NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property off SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2021 SECO-LARM U.S.A., Inc. All rights reserved.