myosuploads 18650 2.4 inch 8CHN Tester Owner’s Manual

August 28, 2024
myosuploads

**myosuploads 18650 2.4 inch 8CHN Tester Owner’s Manual

**

Safety Tips (very important!!!)

  1. DC5V/10 A power supply with sufficient power must be used for power supply; otherwise, the equipment cannot operate normally sufficient power supply
  2. The 18650 battery holder is only applicable to flat-head 18650 battery test. It is not applicable to pointed-head 18650 or other specifications of battery test. Before use, adjust the spring piece and the tightness with pointed-nose pliers.
  3. This equipment is not suitable for charging of lithium iron phosphate battery. The lithium iron phosphate battery for test can only operate in discharge mode. Charging, automatic and active modes are prohibited.
  4. No power-on test is allowed in case of damaged or leaking battery.
  5. The active mode belongs to forced charging mode, which shall not be used by non-professional personnel and personnel shall not leave the site during use.
  6. Heat will be generated during charging and discharging. Keep away from in flammables during use!

Technical parameters

Name: 2.4″ TFT 8-channel 18650 battery tester
Working voltage : DC5V 10A (standard bare machine, Without power supply), over-voltage necessarily burning machine
Power supply interface: @:DC5.5 tinterface, @ 5V positive and negative electrode welding spot
Reverse connection protection of power supply: reverse connection protection is provided, and reverse connection of power supply is prohibited
Channel type: 8 independent channels, independent of each other and independent of each other
Channel synchronization: support 8-channel setting synchronization and set parameters of each channel separately

Operating mode introduction:

  1. AUTO”~Automatic mode
  2. CHG”~Charging mode
  3. DSG™Discharge mode
  4. ACTI®Mode of activation

Charging current: each channel is independent of about 1A non-constant current charging, and the charging current is not adjustable.
Charging (stop) voltage: 3.7V, 3.8V, 3.9V, 4.0V, 4.1V, 4.2V, 6 gears adjustable
Recharge (stop) voltage: 3.0V, 3.1V, 3.2V, 3.3V, 3.4V, 3.5V, 3.6V, 3.7V, 3.8V, 3.9V, 4.0V, 4.1V, 4.2V, 13 gears adjustable
Charging end current: 100mA, 200mA, 300mA, adjustable

Discharge current: each channel is independent of about 1A non-constant current discharge, and the discharge current is not adjustable.

(Discharge) Stop voltage: 2.0V, 2.1V, 2.2V, 2.3V, 2.4V, 2.5V, 2.6V, 2.7V, 2.8V, 2.9V, 3.0V, 3.1V, 3.2V, 3.3V, 3.4V, 3.5V, 3.6V, 17 gears adjustable.
Standstill time: 1~5min adjustable.
Channel status preview: support 1-screen preview of 8-channel status
Single channel detail display: support
Single-channel charging and discharging curve display: support
Internal resistance detection: DC two-wire method for internal resistance measurement, only used for sorting and analogy of the same batch
Heat dissipation mode: active heat dissipation

Overheat protection: support
Cyclic charge and discharge: only one charge – discharge – charge cycle is supported in automatic mode, and multiple cycles are not supported.
External test: it supports external discharge through 2P terminal. A single channel only supports one of the battery base or external test, and cannot use the battery base and external battery for test at the same time.
Reverse connection protection of battery: reverse connection protection is provided, and reverse connection of battery is prohibited.
Product size: 37 x 110 X 310 mm
Packing size: 60 x 112 x 335 mm
Product weight: 410 g (bare machine)/500 g (including packaging)

Illustration of mode flow

  1. AUTO

  2. CHG

  3. DSG

  4. ACTI (Only for professional use, not allowed to leave the site during use)

Product display

  1. Front and back

  2. Power supply interface

  3. Key, screen, cooling fan

  4. Battery holder and expansion terminal

Point A and pointB Cannot be tested simultaneously

  1. Working indicator and status indication

Status Indicator Description

  1. Packaging (without power supply)

Interface display

18 Channel overview actual display

^ Single channel details are actually displayed

The following is a demonstration, not an actual display

  1. Overview of passageway

  2. channel indication

  3. Real-time status indication: CHG(charge)/ STOP /END /WAIT / DSG(discharge )

  4. Real-time battery voltage indication

  5. Real-time working current indication

  6. Capacity metering

  7. Total program run time (hour: minute: second)

  8. Details of access roads

  9. Presentation of voltage and current curves

  10. Voltage coordinate system

  11. Current coordinate system

  12. Time coordinate system

  13. Voltage curve

  14. curve of current

  15. Real time parameter

  16. Real-time battery voltage

  17. Real time current

  18. Operating mode

  19. Work Step Status

  20. Program run time

  21. Battery internal resistance: measured by DC two-wire method

  22. Working step parameters

  23. Channel indication

  24. CHG1 (initial charge): charging voltage – maximum 1A non-constant current charging current – standing time (minute) – charging capacity.

  25. DSG( discharge): discharge stop voltage – maximum 1A non-constant discharge current – standing time (minute) – discharge capacity (main reference data for capacity measurement)

  26. CHG2(Recharge): Recharging voltage – maximum 1A non-constant

  27. Menu

  28. Channel indication

  29. Synchronization or not O Channel setting

  30. Operating mode: AUTO/CHG/DSG/ACTI

  31. CHG1 voltage setting

  32. CHG2 Recharging voltage setting (after discharge)

  33. End current setting

  34. 1A non-constant discharge current (non-adjustable)

  35. Stop (discharge) voltage setting, independent of charge

  36. Setting of standing time: step alternate waiting time (battery cooling time)

Setting method

Demonstration effect, non actual display effect

  1. Switch between channel overview and single channel display Click “3Z#./M” , Toggle display overview and channel details

  2. Enter Menu
    In the overview or detail interface, long press the “% #./M” button for 3 seconds to enter the menu

No action for 10 seconds, or long press the “3 #./M” button for 3 seconds to save the settings and return to the overview interface

  1. Language Under the menu interface, long press “J&i /{5 /R/S” button for 3s to switch language

  2. Mode Click /M  Switch to the mode menu

Click s adjustment operating mode

  1. CHG 1 Click /M Switch to the VoI*CHG 1 menu

Click s adjustment Vol*CHG 1

  1. CHG 2 Click /M “, Switch to the VoI~CHG2 menu

Click+ /s  adjustment VoI*CHG2

  1. Cur~END
    Click “3ZH./M “, Switchto the Cur~END menu

Click /s “,adjustment Cur~END

  1. Vol~STOP
    Click /M “, Switch to the Vol~STOP menu

Click /s “,adjustment Vol~STOP

  1. WatiClick “3Z#./M “ Switch to the Wati menu

Click “ifi%%/s “,adjustment Wati time

  1. Switch to CHN 2 Menu
    Click “/CHN “, Switch toCHN @ Menu

Click “/M “Switch to Sync CHNQ Setting menu

Click “ifi%¢/s “, adjustment YES/NO

When the channel parameters need to be set separately, adjust to “Sync CHNQ @ Setting: No”, and then operate according to steps 5.4~5.9 to complete the corresponding settings.

  1. Switch different channel menusClick “i#i&/CHN “, Switch different channel menus

  2. Operation procedures,

  3. Click “Jd f§/R/S” button to start or stop the current channel program.
    Click “Channel/CHN” button to switch to the next channel.

  4. Long press the “/ {5 /R/S” button for 3 seconds to start the channel program at the same time; To stop the program, enter the individual channel stop program.

Steps to use

Connect 5V/10A power supply!

Install the test battery, pay attention to the positive and negative poles of the battery, and do not install it reversely!

Set the test parameters and start the program, wait for the test to be completed, and the test personnel shall not leave the site when the mode is activated.

Check the test results and disconnect the battery.

—END—