Safety Tips (very important!!!)
- DC5V/10 A power supply with sufficient power must be used for power supply; otherwise, the equipment cannot operate normally sufficient power supply
- The 18650 battery holder is only applicable to flat-head 18650 battery test. It is not applicable to pointed-head 18650 or other specifications of battery test. Before use, adjust the spring piece and the tightness with pointed-nose pliers.
- This equipment is not suitable for charging of lithium iron phosphate battery. The lithium iron phosphate battery for test can only operate in discharge mode. Charging, automatic and active modes are prohibited.
- No power-on test is allowed in case of damaged or leaking battery.
- The active mode belongs to forced charging mode, which shall not be used by non-professional personnel and personnel shall not leave the site during use.
- Heat will be generated during charging and discharging. Keep away from in flammables during use!
Technical parameters
Name: 2.4″ TFT 8-channel 18650 battery tester
Working voltage : DC5V 10A (standard bare machine, Without power supply),
over-voltage necessarily burning machine
Power supply interface: @:DC5.5 tinterface, @ 5V positive and negative
electrode welding spot
Reverse connection protection of power supply: reverse connection
protection is provided, and reverse connection of power supply is prohibited
Channel type: 8 independent channels, independent of each other and
independent of each other
Channel synchronization: support 8-channel setting synchronization and
set parameters of each channel separately
Operating mode introduction:
- AUTO”~Automatic mode
- CHG”~Charging mode
- DSG™Discharge mode
- ACTI®Mode of activation
Charging current: each channel is independent of about 1A non-constant
current charging, and the charging current is not adjustable.
Charging (stop) voltage: 3.7V, 3.8V, 3.9V, 4.0V, 4.1V, 4.2V, 6 gears
adjustable
Recharge (stop) voltage: 3.0V, 3.1V, 3.2V, 3.3V, 3.4V, 3.5V, 3.6V, 3.7V,
3.8V, 3.9V, 4.0V, 4.1V, 4.2V, 13 gears adjustable
Charging end current: 100mA, 200mA, 300mA, adjustable
Discharge current: each channel is independent of about 1A non-constant current discharge, and the discharge current is not adjustable.
(Discharge) Stop voltage: 2.0V, 2.1V, 2.2V, 2.3V, 2.4V, 2.5V, 2.6V, 2.7V,
2.8V, 2.9V, 3.0V, 3.1V, 3.2V, 3.3V, 3.4V, 3.5V, 3.6V, 17 gears adjustable.
Standstill time: 1~5min adjustable.
Channel status preview: support 1-screen preview of 8-channel status
Single channel detail display: support
Single-channel charging and discharging curve display: support
Internal resistance detection: DC two-wire method for internal resistance
measurement, only used for sorting and analogy of the same batch
Heat dissipation mode: active heat dissipation
Overheat protection: support
Cyclic charge and discharge: only one charge – discharge – charge cycle
is supported in automatic mode, and multiple cycles are not supported.
External test: it supports external discharge through 2P terminal. A
single channel only supports one of the battery base or external test, and
cannot use the battery base and external battery for test at the same time.
Reverse connection protection of battery: reverse connection protection
is provided, and reverse connection of battery is prohibited.
Product size: 37 x 110 X 310 mm
Packing size: 60 x 112 x 335 mm
Product weight: 410 g (bare machine)/500 g (including packaging)
Illustration of mode flow
-
AUTO
-
CHG
-
DSG
-
ACTI (Only for professional use, not allowed to leave the site during use)
Product display
-
Front and back
-
Power supply interface
-
Key, screen, cooling fan
-
Battery holder and expansion terminal
Point A and pointB Cannot be tested simultaneously
- Working indicator and status indication
Status Indicator Description
- Packaging (without power supply)
Interface display
18 Channel overview actual display
^ Single channel details are actually displayed
The following is a demonstration, not an actual display
-
Overview of passageway
-
channel indication
-
Real-time status indication: CHG(charge)/ STOP /END /WAIT / DSG(discharge )
-
Real-time battery voltage indication
-
Real-time working current indication
-
Capacity metering
-
Total program run time (hour: minute: second)
-
Details of access roads
-
Presentation of voltage and current curves
-
Voltage coordinate system
-
Current coordinate system
-
Time coordinate system
-
Voltage curve
-
curve of current
-
Real time parameter
-
Real-time battery voltage
-
Real time current
-
Operating mode
-
Work Step Status
-
Program run time
-
Battery internal resistance: measured by DC two-wire method
-
Working step parameters
-
Channel indication
-
CHG1 (initial charge): charging voltage – maximum 1A non-constant current charging current – standing time (minute) – charging capacity.
-
DSG( discharge): discharge stop voltage – maximum 1A non-constant discharge current – standing time (minute) – discharge capacity (main reference data for capacity measurement)
-
CHG2(Recharge): Recharging voltage – maximum 1A non-constant
-
Menu
-
Channel indication
-
Synchronization or not O Channel setting
-
Operating mode: AUTO/CHG/DSG/ACTI
-
CHG1 voltage setting
-
CHG2 Recharging voltage setting (after discharge)
-
End current setting
-
1A non-constant discharge current (non-adjustable)
-
Stop (discharge) voltage setting, independent of charge
-
Setting of standing time: step alternate waiting time (battery cooling time)
Setting method
Demonstration effect, non actual display effect
-
Switch between channel overview and single channel display Click “3Z#./M” , Toggle display overview and channel details
-
Enter Menu
In the overview or detail interface, long press the “% #./M” button for 3 seconds to enter the menu
No action for 10 seconds, or long press the “3 #./M” button for 3 seconds to save the settings and return to the overview interface
-
Language Under the menu interface, long press “J&i /{5 /R/S” button for 3s to switch language
-
Mode Click /M Switch to the mode menu
Click s adjustment operating mode
- CHG 1 Click /M Switch to the VoI*CHG 1 menu
Click s adjustment Vol*CHG 1
- CHG 2 Click /M “, Switch to the VoI~CHG2 menu
Click+ /s adjustment VoI*CHG2
- Cur~END
Click “3ZH./M “, Switchto the Cur~END menu
Click /s “,adjustment Cur~END
- Vol~STOP
Click /M “, Switch to the Vol~STOP menu
Click /s “,adjustment Vol~STOP
- WatiClick “3Z#./M “ Switch to the Wati menu
Click “ifi%%/s “,adjustment Wati time
- Switch to CHN 2 Menu
Click “/CHN “, Switch toCHN @ Menu
Click “/M “Switch to Sync CHNQ Setting menu
Click “ifi%¢/s “, adjustment YES/NO
When the channel parameters need to be set separately, adjust to “Sync CHNQ @ Setting: No”, and then operate according to steps 5.4~5.9 to complete the corresponding settings.
-
Switch different channel menusClick “i#i&/CHN “, Switch different channel menus
-
Operation procedures,
-
Click “Jd f§/R/S” button to start or stop the current channel program.
Click “Channel/CHN” button to switch to the next channel. -
Long press the “/ {5 /R/S” button for 3 seconds to start the channel program at the same time; To stop the program, enter the individual channel stop program.
Steps to use
Connect 5V/10A power supply!
Install the test battery, pay attention to the positive and negative poles of the battery, and do not install it reversely!
Set the test parameters and start the program, wait for the test to be completed, and the test personnel shall not leave the site when the mode is activated.
Check the test results and disconnect the battery.