HALCYON R952 LED Recessed Luminaire User Manual
- June 10, 2024
- HALCYON
Table of Contents
R952 LED Recessed Luminaire
User Manual R952 Installation
R952 LED Recessed Luminaire
RISK OF FIRE — Required clearance from structural members and building
elements
Side Clearance to building element (eg timber, joist or Batten) (SCB): 0mm
Height Clearance to building element (eg timber, joist or Batten) (HCB): 0mm
Minimum Insulation Clearance to building element (MIC): 0mm
Approved clearances
Note: 0mm required but 25mm always recommended for optimum product
lifespan through effective heat dissipation.
DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN Note: Side/Height
Clearance is measured from heat sink.
Recessed Luminaire Classification: IC-F — building insulation that can
safely be continuously exposed to 90°C allowed to abut and cover the
luminaire.
For indoor use
Luminaire must be installed by a Registered Electrician.
CONSTANT CURRENT WIRE IN SERIES.
CHECK MINIMUM LOAD OF DRIVER.
Switch off mains power supply
R952
is designed to be installed at ground level as pictured. Bottom of the fitting
must sit directly on the smooth floor surface with zero gap for desired light
effect.
Cut out 70 x 35mm. Cut holes with extra caution (small rim).
Cutting of holes prior to receiving goods is entirely at the risk of the
installer.
Connect driver to mains voltage cable (L, N). Do not connect
light to driver if driver is live. Inrush current from live driver will cause
instant light failure. Do not switch secondary side.
Halcyon UID driver can be utilised and are able to be installed under
insulation, if using a standard driver install above insulation.
NOTE: if using one driver per R952 we do have a range of mini drivers
available that are designed to fit through the cut out. Their codes begin with
DRMACC or DRDMACC, please refer to our website for options.
Carefully install light into precut 70 x 35mm hole.
Turn on mains power and switch on lighting circuit.
CLASSIFICATION SHEET / IC-F
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R952 |
Product Type | LED Recessed Luminaire |
Secondary Voltage | 350mA Constant Current |
Wattage | 1.05W |
Ingress Protection Rating | IP40 |
Classification |
exposed to 90°C allowed to abut and cover the luminaire.
---|---|---
In the vicinity of the recessed luminaire, use an insulation product that:
(a) Maintains its dimensions and structural integrity when exposed to a
temperature of 90°C; and
(b) Withstands a 30-second needle flame test carried out in accordance with
AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.
Rear of fitting may abut structural members and building elements.
Do not install through or directly into joist, beam, rafter or ceiling batten.
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB: 0mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB: 0mm
Minimum insulation clearance to building element| MIC: 0mm
Recessed luminaires and their associated equipment may pose a risk of fire or
damage to property if not installed and maintained correctly. Halcyon
recommends a clearance of 25mm to building elements for optimum lifespan.
Halcyon IC rated luminaires are completely safe to install in sarked timber
ceiling linings.
Halcyon accepts no responsibility if the timber used is not treated correctly
and dries out, crack or warps over time due to the constant low heat from the
aforementioned 1C Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the
New Zealand Electrical Code of Practice for Installation and Maintenance of
Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001
10 Basalt Place, East Tamaki, Auckland,
PO Box 58-501, Botany, Manukau 2163,
Auckland, New Zealand Ph (0064 9) 273-9177
Fax (0064 9) 273 9155
Email: sales@halcyon.co.nz
Web: www.halcyonlights.co.nz
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>