Specifications

  • Product: Air conditioner
  • Model: AC***BN6PKG
  • Operating Modes: Cool mode, Heat mode, Dry mode
  • Outdoor Temperature Range:
    • Cool mode: -20°C to 52°C
    • Heat mode: -25°C to 24°C
    • Dry mode: -20°C to 52°C
  • Indoor Humidity: Up to 80%

Product Usage Instructions

Safety Information

Before using the air conditioner, read the manual thoroughly for
safe and efficient operation. Follow safety guidelines to prevent
personal injury or property damage.

Installation

Ensure proper installation to avoid hazards. Contact a
professional if unsure. Do not attempt to disassemble the unit.

Power Supply

Make sure the machine is grounded to prevent electric shock. Cut
off the power supply before maintenance. Do not pierce or burn the
unit.

Cleaning

Clean the indoor unit exterior with a slightly wet or dry cloth.
Use a soft brush for odd-shaped areas. Take caution when handling
the heat exchanger.

FAQ

Q: What should I do if my air conditioner displays an error

code?

A: Refer to the troubleshooting section of the manual to
identify and resolve common issues. If problems persist, contact
customer support.

Q: How often should I clean the air filter?

A: Regularly check and clean the air filter every 2-4 weeks to
maintain optimal performance.

“`

Air conditioner
User manual
AC***BN6PKG
· Thank you for purchasing this Samsung air conditioner. · Before operating this unit, please read this manual carefully and retain it for future reference.

Contents

Safety Information

3

Safety Information

3

At a Glance

13

Indoor Unit Overview

13

Operation Features

14

Operating temperature and humidity

14

Cleaning and Maintenance

15

Cleaning and Maintaining

15

Cleaning the indoor unit exterior · Cleaning the outdoor unit heat exchanger

15

Disassembling the air filter · Cleaning the air filter

16

Reassembling the air filter · Periodical maintenance

17

Troubleshooting

18

Technical specifications

22

Information about refrigerant

22

Important information: regulation regarding the refrigerant used

22

Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
For information on Samsung’s environmental commitments and product regulatory obligations, e.g. REACH, visit our sustainability page available via www.samsung.com
2 English

Safety Information

Safety Information
Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance. Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact centre or find help and information online at www. samsung.com.
WARNING Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage.
Follow directions. Do NOT attempt. Make sure the machine is grounded to prevent electric shock. Cut-off the power supply. Do NOT disassemble.
English 3

Safety Information

Safety Information
FOR INSTALLATION
Use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line. · Extending the power line may result in electric shock or fire. · Do not use an electric transformer. This may result in electric
shock or fire. · If the voltage/frequency/rated current condition is different, it
may cause fire. The installation of this appliance must be performed by a qualified technician or service company. · Failing to do so may result in electric shock, fire, explosion,
problems with the product, or injury. Install a switch and circuit breaker dedicated to the air conditioner. · Failing to do so may result in electric shock or fire. Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed. · Failing to do so may result in electric shock or fire. Do not install this appliance near a heater or open flame, as it contains inflammable materials and substances. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. · This may result in electric shock or fire. Never install the outdoor unit in a location such as on a high external wall where it could fall. · If the outdoor unit falls, it may result in injury, death or
property damage.
4 English

Safety Information

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line. · Failure to do so may result in electric shock, fire, an explosion,
or other problems with the product. · Make sure that it is in accordance with local and national codes.
CAUTION
Install your appliance on a level and hard floor that can support its weight. · Failing to do so may result in abnormal vibrations, noise, or
problems with the product. Install the drain hose properly so that water is drained correctly. · Failing to do so may result in water overflowing and property
damage. Avoid adding drain to waste pipes as odours may arise in the future. The product shall be stored in a room with no ignition sources (e.g. open flames, gas appliance, electric heater, etc.). · Note that the refrigerant has no odour. When using the outdoor unit for heating, make sure not to connect a drain hose, a drain plug and a drain cap so that draining is performed more rapidly with less risk of freezing. · The water generated during the heating operation in the outdoor unit may overflow and result in property damage. In particular, in winter, if a block of ice falls, it may result in injury, death or property damage. Do not install the product in a place where thermo- hygrostat is needed (such as server room, machinery room, computer room, etc.) · Those places do not provide guaranteed operation condition of the product therefore performance can be poor in these places.
English 5

Safety Information

Safety Information
FOR POWER SUPPLY
When the circuit breaker is damaged, contact your nearest service centre. Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance. · This may result in electric shock or fire. CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. · Failing to do so may result in electric shock or fire.
FOR USING
WARNING If the appliance is flooded, please contact your nearest service centre. · Failing to do so may result in electric shock or fire. If the appliance generates a strange noise, a burning smell or smoke, cut-off the power supply immediately and contact the nearest service centre. · Failing to do so may result in electric shock or fire.
6 English

Safety Information

In case of a malfunction, immediately stop operation of the air conditioner and disconnect the entire power system. Then consult the authorized service personnel. In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line. · Do not use a ventilating fan. · A spark may result in an explosion or fire. To reinstall the air conditioner, please contact your nearest service centre. · Failing to do so may result in problems with the product,
water leakage, electric shock, or fire. · A delivery service for the product is not provided. If
you reinstall the product in another location, additional construction expenses and an installation fee will be charged. · Especially, when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to salt in the air, please contact your nearest service centre. Do not touch the circuit breaker with wet hands. · This may result in electric shock. Do not turn the air conditioner off with the circuit breaker while it is operating. · Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire.
English 7

Safety Information

Safety Information
After unpacking the air conditioner, keep all packaging materials well out of the reach of children, as packaging materials can be dangerous to children. · If a child places a bag over its head, it may result in
suffocation. Do not touch the front panel with your hands or fingers during the heating operation. · This may result in electric shock or burns. Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating or the front panel is closing. · Take special care that children do not injure themselves by
inserting their fingers into the product. Do not insert your fingers or foreign substances into the air inlet/ outlet of the air conditioner. · Take special care that children do not injure themselves by
inserting their fingers into the product. Do not strike or pull the air conditioner with excessive force. · This may result in fire, injury, or problems with the product. Do not place an object near the outdoor unit that allows children to climb onto the machine. · This may result in children seriously injuring themselves. Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people. · Since this may be dangerous due to a lack of oxygen, open a
window at least once an hour. Do not use means to accelerate the defrost operation or to clean, other than those recommended by Samsung.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
8 English

Safety Information

If any foreign substance such as water has entered the appliance, cut-off the power supply and contact the nearest service centre. · Failing to do so may result in electric shock or fire. Do not attempt to repair, disassemble, or modify the appliance yourself. · Do not use any fuse (such as copper, steel wire, etc.)other than
the standard fuse. · Failing to do so may result in electric shock, fire, problems
with the product, or injury. CAUTION
Do not place objects or devices under the indoor unit. · Water dripping from the indoor unit may result in fire or
property damage. Check that the installation frame of the outdoor unit is not broken at least once a year. · Failing to do so may result in injury, death or property
damage. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency. When the air conditioner does not operate properly for cooling or heating, there is a possibility of refrigerant leakage. If any leakage, stop operation, ventilate the room, and consult your dealer immediately for recharging refrigerant. The refrigerant is not harmful. However, if it comes in contact with fire, it may generate harmful gases and there is risk of fire.
English 9

Safety Information

Safety Information
During transportation of the indoor unit, the pipe lines shall be covered with brackets for protection. Do not move the product with holding the pipe lines. · It may cause gas leakage. Do not install the product in a ship or a vehicle (such as a campervan). · Salt, vibration or other environmental factor may cause the
product malfunction, electric shock or fire. Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on the appliance. · This may result in electric shock, fire, problems with the
product, or injury. Do not operate the appliance with wet hands. · This may result in electric shock. Do not spray volatile material such as insecticide onto the surface of the appliance. · As well as being harmful to humans, it may also result in
electric shock, fire or problems with the product. Do not drink the water from the air conditioner. · The water may be harmful to humans. Do not apply a strong impact to the remote controller and do not disassemble the remote controller. Do not touch the pipes connected with the product. · This may result in burns or injury.
10 English

Safety Information

Do not cut or burn the refrigerant container or pipings. Do not point the air direction to the fireplace or heater. Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes. · This may result in property damage. Avoid directly exposing humans, animals or plants to the air flow from the air conditioner for long periods of time. · This may result in harm to humans, animals or plants. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. For use in Europe: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
English 11

Safety Information

Safety Information
FOR CLEANING
WARNING Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner, alcohol or acetone to clean the appliance. · This may result in discoloration, deformation, damage, electric
shock or fire. Before cleaning or performing maintenance, cut-off the power supply and wait until the fan stops. · Failing to do so may result in electric shock or fire. CAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges. · To avoid cutting your fingers, wear thick cotton gloves when
cleaning it. · This should be done by a qualified technician please contact
your installer or service centre. Do not clean the inside of the air conditioner by yourself. · For cleaning inside the appliance, contact your nearest service
centre. · When cleaning the internal filter, refer to the descriptions in
the `Cleaning and Maintaining’ section. · Failure to do may result in damage, electric shock or fire. · Make sure to prevent any injury from sharp edges of the
surface when handling the heat exchanger.
12 English

Indoor Unit Overview
Square panel

Circular panel

At a Glance

01 02 03 04

01 Display

Operation status Power on In operation Stopped Timed on/off function Requires filter cleaning
Defrost function

Indication on the display Ice blue (blinking) Ice blue Off Blue Yellow green
Ice blue (blinking once every 10 seconds)

Wide

Mid

Spot

Swing

NOTE
· For the AR-KH0 wireless remote control, the air flow direction indications appear on its display, too.
· By using the AR-KH0
wireless remote control, you can turn on or turn off the air flow direction indications that appear on the indoor unit display.
· For the AR-EH0, AR-EC0 wireless remote control, which is designed generally for any indoor units, the air flow direction is not shown on the remote control display. Control the air flow direction with checking it on the indoor unit display.
02 Remote control sensor (behind the front grille) 03 Air outlet 04 Front grille / Air filter (behind the front grille)
NOTE
· For information on how to operate the product, see the user manual for the remote control.
· The actual appearances of the indoor units and their displays may differ slightly from the images depicted above.
· By using the AR-KH0** wireless remote control, which is designed specifically for the 360 cassette indoor units, you can operate them more conveniently. In addition, because you can check the operation status of each indoor unit on the remote control, you can use the indoor units more effectively.

English 13

Operation Features

Operating temperature and humidity

Mode Cool mode Heat mode Dry mode

Outdoor temperature -20 to 52 -25 to 24 -20 to 52

Indoor temperature 18°C to 32°C 30°C or less 18°C to 32°C

Indoor humidity 80% or less 80% or less

CAUTION
· If you use the air conditioner at a relative humidity above 80%, it may cause a formation of condensation and a leakage of water on the floor.
· The rated heating capacity is based on an outdoor temperature of 7°C. If the outdoor temperature goes down below 0°C, heating efficiencies may decrease depending on the temperature conditions.
· If the indoor unit is out of the operating temperature and humidity range, the safery device may operate and the air conditioner may stops.
· If the indoor unit is installed in an IT room (for example, computer room), a separate back-up system must be installed, and the reliability of our product cannot be guaranteed at temperatures outside the operating temperature range.

At a Glance

14 English

Cleaning and Maintaining
Cleaning the indoor unit exterior

Cleaning and Maintenance

Wipe the surface of the unit with a slightly wet or dry cloth when needed. Wipe off dirt from odd-shaped areas by using a soft brush.
CAUTION
· Do not use alkaline detergent, sulphuric acid, hydrochloric acid, or organic solvents (such as thinner, kerosene, and acetone) to clean the surfaces.
· Do not put any stickers on it as this can damage the surface of the indoor unit.
Cleaning the outdoor unit heat exchanger

Spray water to clean the dust.

NOTE
· When you clean and inspect the heat exchanger on the outdoor unit, contact the local service centre for help.
CAUTION
· Make sure to prevent any injury from sharp edges of the surface when handling the heat exchanger.

English 15

Cleaning and Maintaining
Disassembling the air filter
CAUTION
· For cleaning and maintenance, be sure to turn off the circuit breaker. NOTE
· When the next filter-cleaning time arrives (after 1000 hours of operation), the indoor unit display appears in yellow green.
Cleaning the air filter
NOTE · Clean the air filter once every two weeks. · Spray water or use a vacuum cleaner to remove dust. · After removing dust, dry the air filter completely.
Avoid direct sunlight. Failure to do so may deform the air filter. 16 English

Cleaning and Maintenance

Reassembling the air filter

Cleaning and Maintenance

After cleaning and reassembling the air filter, reset the filter-cleaning reminder as follows:

· AR-KH0** remote control:

Select Filter Reset.

· AR-EH0, AR-EC0 remote control: Hold down the Filter Reset button for two seconds.

NOTE
· If you try to assemble the air filter upside down, it will not be assembled because it cannot be clamped by the internal structure.

Periodical maintenance

Unit

Maintenance item

Interval

Indoor unit
Outdoor unit

Clean the air filter. Clean the condensate drain pan. Clean up the heat exchange. Clean the condensate drain pipe. Replace the remote control batteries. Clean the heat exchanger on the outside of the unit. Clean the heat exchanger on the inside of the unit. Clean the electric components with jets of air. Verify that all the electric components are firmly tightened. Clean the fan. Verify that the fan assemblies are firmly tightened. Clean the condensate drain pan.

At least once a month Once a year Once a year Once every 4 months At least once a year Once every 4 months Once a year Once a year
Once a year
Once a year Once a year Once a year

Requires qualified technicians
Required Required Required
Required Required Required Required Required Required Required

English 17

Cleaning and Maintaining

Troubleshooting

Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expense.

Problem The air conditioner does not operate immediately after it has been restarted.
The air conditioner does not operate at all.

Solution
· Because of the protective mechanism, the appliance does not start operating immediately to keep the unit from overloading. The air conditioner will start in 3 minutes.
· Check whether the power is turned on, and then operate the air conditioner again.
· Check whether the auxiliary power switch (MCCB, ELB) is turned on. · If the auxiliary power switch (MCCB, ELB) is turned off, the air conditioner
does not work although you press the (Power) button. · When you clean the air conditioner or do not use it for an extended period of
time, turn off the auxiliary power switch (MCCB, ELB). · After the air conditioner is not used for an extended period of time, be sure
to turn on the auxiliary power switch (MCCB, ELB) 6 hours before starting operation.

The temperature does not change.
Warm air does not come out of the air conditioner.
The fan speed does not change.

NOTE
· The auxiliary power switch (MCCB, ELB) is sold separately. · Make sure that auxiliary power switch (MCCB, ELB) is installed in the
distribution box inside the building. · If the air conditioner is turned off by the Timed off function, turn on the air
conditioner again by pressing the (Power) button.
· Check whether the Fan mode is running. In the Fan mode, the air conditioner controls the set temperature automatically, and you cannot change the set temperature.
· Check whether the outdoor unit is designed for cooling only. In this case, warm air does not come out although you select the Heat mode.
· Check whether the remote control is designed only for cooling only. Use a remote control that supports both cooling and heating.
· Check whether the Auto or Dry mode is running. In these modes, the air conditioner controls the fan speed automatically, and you cannot change the fan speed.

Cleaning and Maintenance

18 English

Problem
The wireless remote control does not operate.

Solution
· Check whether the batteries are discharged. Replace the batteries with new ones.
· Make sure that nothing is blocking the remote control sensor. · Check whether any strong lighting sources are near the air conditioner.
Strong light which comes from fluorescent bulbs or neon signs may interfere with the remote control.

The wired remote control does not operate.

· Check whether the indicator is displayed at the bottom right of the remote control display. In this case, turn off both the air conditioner and the auxiliary power switch, and then contact a service centre.

The air conditioner is not turned on or off immediately with the wired remote control.

· Check whether the wired remote control is set for group control. In this case, the air conditioners connected to the wired remote control are turned on or off sequentially. This operation takes up to 32 seconds.

The Timed on/off function does not operate.

· Check whether you pressed the (SET) button on the remote control after setting the on/off time. Set the on/off time.

The indoor unit display blinks continuously.
I want to get cooler air.

· Turn on the air conditioner again by pressing the (Power) button. · Turn off and then turn on the auxiliary power switch, and then turn on the
conditioner. · If the indoor unit display is still blinking, contact a service centre.
· Operate the air conditioner with a electric fan to save energy and enhance the cooling efficiency.

Cleaning and Maintenance

English 19

Cleaning and Maintaining

Problem
The air is not cool or warm enough.

Solution
· In the Cool mode, cool air does not come out if the set temperature is higher than the current temperature.
AR-EH0, AR-EC0 remote control: Press the Temperature button repeatedly until the set temperature (minimum: 18°C) is set to lower than the current temperature.
AR-KH0 remote control: Press the Temperature button on the remote control. Then rotate the Wheel until the set temperature (minimum: 18°C) is set to lower than the current temperature.
· In the Heat mode, warm air does not come out if the set temperature is lower than the current temperature.
AR-EH0
, AR-EC0 remote control: Press the Temperature button repeatedly until the set temperature (maximum: 30°C) is set to higher than the current temperature.
AR-KH0
remote control: Press the Temperature button on the remote control. Then rotate the Wheel until the set temperature (maximum: 30°C) is set to higher than the current temperature.
· Both cooling and heating do not operate in the Fan mode. Select the Cool, Heat, Auto, or Dry mode.
· Check whether the air filter is blocked with dirt. A dusty filter may decrease the cooling and heating efficiencies. Clean the air filter frequently.
· If a cover is on the outdoor unit or any obstacle is present near the outdoor unit, remove them.
· Install the outdoor unit in a well-ventilated place. Avoiding places exposed to direct sunlight or close to a heating appliance.
· Place a sunscreen over the outdoor unit to protect it from direct sunlight.
· If the indoor unit is installed in a place exposed to direct sunlight, pull the curtains on the windows.
· Close the windows and doors to maximize the cooling and heating efficiencies.
· If the Cool mode is stopped and then started immediately, cool air comes out after about 3 minutes to protect the compressor of the outdoor unit.
· When the Heat mode is started, warm air does not come out immediately to prevent cool air from coming out at the beginning.
· If the refrigerant pipe is too long, the cooling and heating efficiencies may be decreased. Avoid exceeding the maximum pipe length.

Cleaning and Maintenance

20 English

Problem
The air conditioner makes strange noises.
Unpleasant odours permeate the room.
Steam is produced on the indoor unit. The outdoor unit fan continues to operate when the air conditioner is turned off. Water drops from the piping connections of the outdoor unit. Steam is produced on the outdoor unit.

Solution · In certain conditions (especially, when the outdoor temperature is lower
than 20°C), a hissing, rumbling, or splashing sound may be heard while the refrigerant is circulating through the air conditioner. This is a normal operation.
· When you press the (Power) button on the remote control, noise may be heard from the drain pump inside the air conditioner. This noise is a normal sound.
· If the air conditioner is running in a smoky area or if there is a smell entering from outside, ventilate the room properly.
· If both indoor temperature and indoor humidity are high, operate the air conditioner in the Clean or Fan mode for 1 to 2 hours.
· If the air conditioner has not been operated for an extended period of time, clean the indoor unit and then operate the air conditioner in the Fan mode for 3 to 4 hours to dry the inside of the indoor unit for removal of unpleasant odours.
· If the air filter blocked with dirt, clean the air filter. · In winter, if the indoor humidity is high, steam may be produced around the
air outlet while the defrost function is running. This is a normal operation.
· When the air conditioner is turned off, the outdoor unit fan may continue to operate to reduce noise of the refrigerant gas. This is a normal operation.
· Condensation may develop due to the difference in temperature. This is a normal condition.
· In winter, when the air conditioner runs in the Heat mode, the frost on the heat exchanger melts and steam may be produced. This is a normal operation, neither product malfunction nor a fire.

Cleaning and Maintenance

English 21

Technical specifications

Type Indoor unit

Model AC052BN6PKG AC071BN6PKG AC100BN6PKG AC120BN6PKG AC140BN6PKG

Net weight 20.2 kg 25.5 kg 25.5 kg 25.5 kg 25.5 kg

Net dimension(W x D x H) 947 mm x 947 mm x 281 mm 947 mm x 947 mm x 365 mm 947 mm x 947 mm x 365 mm 947 mm x 947 mm x 365 mm 947 mm x 947 mm x 365 mm

Information about refrigerant

Important information: regulation regarding the refrigerant used

This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
CAUTION
· If the system contains 5 tCOe or more of fluorinated greenhouse gases, it must be checked for leakage at least once every 12 months, according to regulation No. 517/2014. This activity must be covered by qualified personnel only. In the case of the situation above, the installer (or authorized person with responsibility for final check) must provide a maintenance book, with all the information recorded, according to REGULATION (EU) No. 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on fluorinated greenhouse gases.

Refrigenat type R-32
· GWP: Global Warming Potential · Calculating tCOe: kg x GWP/1000

GWP value 675

Cleaning and Maintenance

22 English

Cleaning and Maintenance

Memo English 23

QUESTIONS OR COMMENTS?

COUNTRY UK
IRELAND (EIRE) GERMANY FRANCE SPAIN
PORTUGAL
LUXEMBURG NETHERLANDS
BELGIUM
NORWAY DENMARK FINLAND SWEDEN AUSTRIA
SWITZERLAND
HUNGARY CZECH SLOVAKIA CROATIA BOSNIA

CALL 0333 000 0333 0818 717100 06196 77 555 77 01 48 63 00 00
91 175 00 15 210 608 098 Chamada para a rede fixa nacional Dias úteis das 9h às 20h 261 03 710 088 90 90 100
02-201-24-18
21629099 707 019 70 030-6227 515 0771-400 300 0800 72 67 864 (0800-SAMSUNG)
0800 726 786
0680SAMSUNG (0680-726-7864) 800 – SAMSUNG (800-726786) 0800 – SAMSUNG (0800-726 786)
072 726 786 055 233 999

OR VISIT US ONLINE AT www.samsung.com/uk/support www.samsung.com/ie/support www.samsung.com/de/support www.samsung.com/fr/support www.samsung.com/es/support
www.samsung.com/pt/support
www.samsung.com/be_fr/support www.samsung.com/nl/support www.samsung.com/be/support (Dutch)
www.samsung.com/be_fr/support (French)
www.samsung.com/no/support www.samsung.com/dk/support www.samsung.com/fi/support www.samsung.com/se/support www.samsung.com/at/support www.samsung.com/ch/support
(German) www.samsung.com/ch_fr/support
(French) www.samsung.com/hu/support www.samsung.com/cz/support www.samsung.com/sk/support www.samsung.com/hr/support www.samsung.com/ba/support

COUNTRY

CALL

OR VISIT US ONLINE AT

North Macedonia

023 207 777

www.samsung.com/mk/support

MONTENEGRO

020 405 888

www.samsung.com/support

SLOVENIA

080 697 267 (brezplacna stevilka)

www.samsung.com/si/support

SERBIA

011 321 6899

www.samsung.com/rs/support

Kosovo

038 40 30 90

www.samsung.com/support

ALBANIA

045 620 202

www.samsung.com/al/support

BULGARIA

0800 111 31 –
*3000 –
09:00 18:00 –

www.samsung.com/bg/support

ROMANIA

0800872678 – Apel gratuit *8000 – Apel tarifat în reea
Program Call Center Luni – Vineri: 9 AM – 6 PM

www.samsung.com/ro/support

ITALIA

800-SAMSUNG (800.7267864)

www.samsung.com/it/support

CYPRUS 8009 4000 only from landline, toll free

GREECE

80111-SAMSUNG (80111 726 7864) from mobile and land line (+30) 210 6897691
from mobile and land line

www.samsung.com/gr/support

POLAND

801-172-678 (oplata wedlug taryfy operatora)

http://www.samsung.com/pl/ support/

LITHUANIA

8-800-77777

www.samsung.com/lt/support

LATVIA

8000-7267

www.samsung.com/lv/support

ESTONIA

800-7267

www.samsung.com/ee/support

UKRAINE

0-800-502-000

www.samsung.com/ua/support

MOLDOVA

+373-22-667-400

www.samsung.com/ua/support/ moldova

Samsung, PO Box 12987, Blackrock, Co. Dublin. IE or Euro QA Lab. Saxony Way, Yateley, Hampshire GU46 6GG, UK

This appliance is filled with R-32.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals