TEKTELIC FLUX Smart Outlet User Guide
- August 29, 2024
- TEKTELIC
Table of Contents
TEKTELIC FLUX Smart Outlet
FLUX SMART OUTLET
Specifications
- Input Voltage: 120V
- Radio: LoRa
- Remote Features: consumed energy (kWh), line voltage (Vrms), load current (Arms), load power (real, reactive, and apparent, W), load power factor
- Device Class: C-class
- Frequency Band: US915
Operating Instructions
Included Product and Accessories
Ensure the package contains the FLUX Smart Outlet and any accompanying accessories.
Unpacking and Inspection
Unbox the FLUX Smart Outlet and inspect for any visible damage before
installation.
Local Operation
Operate the FLUX Smart Outlet locally for immediate control over connected
devices.
LED Behaviour
Understand the LED indicators on the FLUX Smart Outlet for status
notifications.
FAQ
-
Q: How do I reset the FLUX Smart Outlet?
A: To reset the FLUX Smart Outlet, press and hold the reset button for 10 seconds until the LED flashes rapidly. -
Q: Can I connect multiple devices to the FLUX Smart Outlet?
A: Yes, you can connect multiple devices to the FLUX Smart Outlet as long as the total power consumption does not exceed its rated capacity.
FLUX SMART OUTLET
User Guide
Document Number: T0006623 – FLUX
Document Version: V2
Release Date: 7 June 2024
Product Description
Overview
FLUX is a 120V Smart Outlet has the form factor of a standard NEMA 5-15R
Decorator style duplex tamper-resistant receptacle (see Figure 1-1) but
incorporates a LoRa radio with power control and monitoring circuitry which
allows for the following remote user features:
- Power on-off control and status
- Precise measurement of:
- consumed energy (kWh)
- line voltage (Vrms)
- load current (Arms)
- load power (real, reactive, and apparent, W)
- load power factor
FLUX is a C-class device which means one can send a downlink to FLUX and get a
reply in real time without the wait of an uplink to transmit the downlink.
Connected via LoRaWAN, enables seamless transmission and reception in US915
frequency band.
This document provides comprehensive descriptions of FLUX Smart Outlet, along
with detailed guidance on its hardware capabilities. For insights into the
functional operation and software behavior, please consult the Technical
Reference Manual (TRM) document.
Specifications
AURA specifications are listed in Error! Reference source not found.. The main
sensing functions are described in the following subsections.
Table 1-1: AURA Specifications
Parameter | Specification |
---|---|
Dimensions | 43 mm (1.7”) W x 46 mm (1.8”) D x 104 mm (4.1”) H |
Weight | 0.12 kg (0.26 lb) |
Air Interface | LoRa US915 (902 – 928 MHz) Class C |
Operating Control | Type 1.C Action |
Environment | Indoor residential & commercial 0 to 40 °C (-40 to 104°F) |
5 – 95% non-condensing RH
Pollution Degree 2
Line| 120 VAC, 60 Hz, 15 A circuit
Load| 1800 W (15 A) Resistive
1000 W Incandescent 5 A Electronic ballast 1200 VA Standard ballast
½ HP Motor
Wire Termination| Max. 2 wires per terminal except 1 wire for Ground #14 – #12
AWG copper or copper clad solid conductor 16 mm (5/8”) strip length
Torque terminal screw to 2.3 N.m (20 lbf-in)
Surge Prot.| IEEE C62.41 Category A
Impulse Voltage| 2500 V
Approvals| cUL (E515077)
FCC Pt. 15, RSS-247, FCC Pt. 27
Operating Instructions
Included Product and Accessories The following items are shipped with each sensor:
- 1x FLUX Smart Outlet device.
- 1x corresponding device Quick Start Guide.
NOTE: to ensure safe installation and maintenance please read Safety Precautions.
Unpacking and Inspection
The following should be considered during the unpacking of a new sensor.
- Inspect the shipping carton and report any significant damage to TEKTELIC.
- Unpacking should be conducted in a clean and dry location.
- Do not discard the shipping box or inserts as they will be required if a unit is returned for repair or re-configuration.
Installation Procedure
The following steps are required to install FLUX:
-
Locate the electrical box into which the FLUX will be installed.
-
Remove power to the wiring by turning off circuit power at the circuit breaker or fuse panel.
-
Test the existing wiring to ensure that power has been removed.
-
inspect the electrical box, a box depth of at least 2” is required. The electrical box may be metal or plastic but a plastic box will result in the best all-around RF performance.
-
Identify the appropriate wiring diagram for your installation situation. Common installation diagrams are described in Figure 2-1, other options are possible. Always follow appropriate electrical codes and regulations.
-
Ttrip wire insulation back 5/8” (16 mm) and maintain a straight conductor for each of the wires to be terminated to the switch module.
-
Connect the wires to the module in accordance with the wiring diagram by inserting the bare wire fully into the wire hole for each of the Line (Hot), Load (Neutral), and Ground terminals on the switch module.
-
Once the module is fully wired, push the wiring and the module into the electrical box, secure the module with the two mounting ear screws, and install the trim plate with the two trim plate screws. Always use a plastic faceplate for best RF reception.
-
Reapply power to the circuit. The module faceplate LED will now begin to flash indicating connection to a LoRa network is underway.
-
Observe the load and test using the local on-off press button.
-
Commission the module as Class C device on the appropriate LoRa network.
Commissioning
Each sensor has a set of commissioning information that must be entered into
the network server for the sensor to be able to join the network and begin
normal operation once activated. For instructions on how to do this please
refer to the Network Server Quick Start Guide you get in the box with the
device (also available online in the Knowledge Base).
Operation
Smart Outlet
Only the lower receptacle is controlled and monitored, the top receptacle is
always live when line power is connected to the module and any connected load
does not contribute to the energy monitoring.
Remote Operation
The top outlet is always powered but doesn’t count towards energy use
tracking. Only the bottom outlet can be turned on or off remotely using LoRa.
When the module is powered up, the bottom outlet stays off by default. You can
control the bottom outlet’s power remotely via LoRa.
Information available through the LoRa radio network:
- measurement of energy supplied to the connected load
- line voltage
- load current
- load power (real, reactive, and apparent)
- load power factor
For details please refer to the TEKTELIC Communications Technical Reference Manual (TRM).
Local Operation
The load of the bottom receptacle can be turn on or off by pressing the
button. This load status change will be reported over the LoRa network. This
load status change will be reported over the LoRa network and will be
indicated on the blue LED.
LED Behaviour
The module faceplate has a Blue LED indicator:
Table 1-1: FLUX LEDs
LED | Description |
---|---|
On | Load power is OFF |
Module is connected to LoRaWAN
Off| Load power is ON
Module is connected to LoRaWAN
90% On – 10% Off
1s cadence| Load power is OFF
Module is connecting to LoRaWAN
10% On – 90% Off
1s cadence| Load power is ON
Module is connecting to LoRaWAN
Basic Downlinks
- FLUX use a “tick” system for reporting data. Generally, telemetry reporting time interval in seconds = core tick time interval * number of ticks per reporting.
- There are two sets of settings that must be configured in conjunction – “Core reporting tick in seconds” and “Ticks per [data/report]”. “Core reporting tick in seconds” will determine the interval between ticks. For example, you can set it to 60 seconds.
- “Ticks per [data/report]” determines how many ticks it will take before the sensor reports any data. For example, if you set “Ticks per Power Meter” to 60, it will take 60 core ticks before the sensor reports battery data (You will see the report every hour”.
- To Change the Core Report to Every 15 Minute Send the Downlink: a0 00 00 03 84 port 100.
- FLUX doesn’t have a decoder included in Atlas. However, it is possible to send the downlink in online mode as shown in the picture.
Send the Downlink: 000100 port 100.
To open the relay
Send the Downlink: 0001ff port 100.
Examples Of Uplinks
0x00 0xFE 0x00 0x01 0x51 0x80 0x00 0x00 0x6A 0x50 0x00 0x00 0x00:
- Energy Consumption Meter:
- Total elapsed time: 86400 seconds (= 24 hours)
- Total energy consumed: 27216 W-h (= 27.216 kW-h)
- Energy Consumption Meter Status Indicator:
- Status: Idle (stopped)
Example of data on LeapX
Data converters
Please follow this link: https://github.com/TektelicCommunications/data-
converters/tree/master for the data converters that are to be used on
TEKTELIC & other Network Server for TEKTELIC Sensors. These data converters
can be used as a reference for other platforms.
TEKTELIC’s data converters conform to the LoRa Alliance Payload Codec
Specification and can be used with any 3rd party Network Server / Application
Server that supports this specification. https://resources.lora-alliance.org
/technical-specifications/ts013-1-0-0-payload-codec-api
Safety Precautions
The following safety precautions should be observed for FLUX installation:
-
TO AVOID FIRE, SHOCK, OR DEATH, ALWAYS TURN OFF POWER at the circuit breaker or fuse panel before wiring the module!
If you are unsure or uncomfortable with installation of this module, consult an electrician. -
To be installed in a standard electrical box and used in accordance with appropriate electrical codes and regulations.
-
To be installed with copper or copper clad wires only.
-
Exercise caution when powering loads from the LoRa radio- controlled switch. Loads connected to this switch may be automatically powered on by a timer or by a remote user. Such unexpected operation may present a hazardous condition for local personnel.
-
This product shall not be used with medical and/or life support equipment.
Compliance Statements
Federal Communications Commission:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
To comply with FCC exposure limits for general population / uncontrolled
exposure, this device should be installed at a distance of 20 cm from all
persons and must not be co-located or operating in conjunction with any other
transmitter.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in an
industrial installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Innovation, Science and Economic Development Canada (Industry Canada):
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation,
Science and Economic Development Canada’s licence-exempt RSS(s). Operation is
subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This device should be installed and operated with minimum distance 0.2 m from human body.
California Proposition 65:
WARNING: This product can expose you to chemicals including lead, nickel, and
carbon black, which are known to the State of California to cause cancer,
birth defects or other reproductive harm. For more information, go to
www.P65Warnings.ca.gov
TEKTELIC Communications Inc.
User Guide
T0006623-FLUX_UG_v2
Confidential Page 13 of 13
References
- P65Warnings.ca.gov
- p65warnings.ca.gov/
- GitHub - TektelicCommunications/data-converters
- TS013-1.0.0 Payload Codec API
Read User Manual Online (PDF format)