WARNING
FOR YOUR SAFETY – This product must be installed and serviced by a
contractor who is licensed and qualified in pool equipment by the jurisdiction
in which the product will be installed, where such state or local requirements
exist. In the event no such state or local requirement exists, the maintainer
must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual
can be followed exactly. Improper installation and/or operation can create
dangerous electrical hazards, which can cause high voltages to run through the
electrical system. Before installing this product, read and follow all warning
notices and instructions that accompany this product. Failure to follow
warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the
warranty.
If these instructions are not followed exactly, a fire or explosion may
result, causing property damage, personal injury, or death.
ATTENTION INSTALLER : This manual contains important information about
the installation, operation, and safe use of this product. This information
should be given to the owner/operator of this equipment.
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION………………..
INSTALLER INFORMATION…………………………………
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)…………………………
PUMP MODEL………………………………………………………………………….
NOTES:………………………………………………………………………………………………..
HORSEPOWER………………………………………………………………………………………….
Section 1. IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL
INSTRUCTIONS
Safety Instructions
All electrical work must be performed by a licensed electrician and conform to
all national, state, and local codes. When installing and using this
electrical equipment, basic safety precautions should always be followed,
including the following:
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the
backwash (multiport, slide, or full flow) valve position with the pump
running.
WARNING
Polaris pumps are powered by a high voltage electric motor and must be
installed by a licensed or certified electrician or a qualified swimming pool
service technician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH. Connect only to
a branch circuit that is protected by a ground-fault circuit-interrupter
(GFCI). Contact a qualified electrician if you cannot verify that the circuit
is protected by a GFCI. Make sure such a GFCI should be provided by the
installer and should be tested on a routine basis. To test the GFCI, push the
test button. The GFCI should interrupt power. Push the reset button. Power
should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button
being pushed, a ground current is flowing, indicating the possibility of
electrical shock. Do not use the pump. Disconnect the pump and have the
problem corrected by a qualified service representative before using. Due to
the potential risk of fire, electric shock, or injuries to persons, Zodiac
Pumps must be installed in accordance with the National Electrical Code®
(NEC®), all local electrical and safety codes, and the Occupational Safety and
Health Act (OSHA®). Copies of the NEC may be ordered from the National Fire
Protection Association® (NFPA®) online at www.nfpa.org or call
617-770-3000, or contact your local
government inspection agency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property
damage.
WARNING
- Do not connect the system to an unregulated city water system or another external source of pressurized water producing pressures greater than 35 PSI.
- Trapped air in the system can cause the filter lid to be blown off, which can result in death, serious personal injury, or property damage. Be sure all air is out of the system before operating.
WARNING
To minimize the risk of severe injury or death the filter and/or pump should
not be subjected to the piping system pressurization test. Local codes may
require the pool piping system to be subjected to a pressure test. These
requirements are generally not intended to apply to the pool equipment such as
filters or pumps. Polaris pool equipment is pressure tested at the factory.
However, if the WARNING cannot be followed and pressure testing of the piping
system must include the filter and/or pump, BE SURE TO COMPLY WITH THE
FOLLOWING SAFETY INSTRUCTIONS:
- Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly installed and secured before testing.
- RELEASE ALL AIR in the system before testing.
- Water pressure for the test must NOT EXCEED 35 PSI.
- The water temperature for the test must NOT EXCEED 100°F (38°C).
- Limit test to 24 hours. After the test, visually check the system to be sure it is ready for operation.
- NOTICE: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult the equipment manufacturer.
WARNING
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause
filters and other equipment to fail, resulting in severe injury or property
damage. Do not store pool chemicals near your equipment.
CAUTION
Do not start pumping dry! Running the pump dry for any length of time will
cause severe damage and will void the warranty.
CAUTION
This pump is for use with permanently installed pools and may also be used
with hot tubs and spas if so marked. Do not use with storable pools. A
permanently installed pool is constructed in or on the ground or in a building
such that it cannot be readily disassembled for storage. A storable pool is
constructed so that it may be readily disassembled for storage and reassembled
to its original integrity.
CAUTION
Do not install within an outdoor enclosure or beneath the skirt of a hot tub
or portable spa. The pump requires adequate ventilation to maintain air
temperature at less than the maximum ambient temperature rating listed on the
motor rating plate.
SAVE THESE INSTRUCTIONS
WARNING
Pump suction is hazardous and can trap and drown or disembowel bathers. Do not
use or operate swimming pools, spa, or hot tubs if a suction outlet cover is
missing, broken, or loose. The following guidelines provide information for
pump installation that minimizes the risk of injury to users of pools, spas,
and hot tubs: Entrapment Protection – The pump suction system must provide
protection against the hazards of suction entrapment.
Suction Outlet Covers – All suction outlets must have correctly
installed, screw-fastened covers in place. All suction outlet (drain) covers
must be maintained. Drain covers must be listed/certified to the latest
version of ANSI®/ASME® A112.19.8 or its successor standard, ANSI/APSP-16. They
must be replaced if cracked, broken, or missing.
A number of Suction Outlets Per Pump – Provide at least two (2)
hydraulically balanced main drains, with covers, as suction outlets for each
circulating pump suction line. The centers of the main drains (suction
outlets) on any one (1) suction line must be at least three (3) feet apart,
center to center. See Figure 1.
The system must be built to include at least two (2) suction outlets (drains)
connected to the pump whenever the pump is running. However, if two (2) main
drains run into a single suction line, the single suction line may be equipped
with a valve that will shut off both main drains from the pump. The system
shall be constructed such that it shall not allow for separate or independent
shutoff or isolation of each drain. See Figure 1.
More than one (1) pump can be connected to a single suction line as long as
the requirements above are met.
Water Velocity – The maximum water velocity through the suction fitting
or cover for any suction outlet must be 1.5 feet per second unless the outlet
complies with the latest version of ANSI/ASME A112.19.8 or its successor
standard, ANSI/APSP-16, the standard for Suction Fittings For Use in Swimming
Pools, Wading Pools, Spas, and Hot Tubs. In any case, do not exceed the
suction fitting’s maximum designed flow rate.
If 100% of the pump’s flow comes from the main drain system, the maximum water
velocity in the pump suction hydraulic system must be six (6) feet per second
or less, even if one (1) main drain (suction outlet) is completely blocked.
The flow through the remaining main drain(s) must comply with the latest
version of ANSI/ASME A112.19.8 or its successor standard, ANSI/APSP-16, the
standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas,
and Hot Tubs.
Testing and Certification – Suction outlet covers must have been tested
by a nationally recognized testing laboratory and found to comply with the
latest version of ANSI/ASME A112.19.8 or its successor standard, ANSI/
APSP-16, the standard for Suction Fittings For Use in Swimming Pools, Wading
Pools, Spas, and Hot Tubs.
Fittings – Fittings restrict flow; for best efficiency use the fewest
possible fittings (but at least two (2) suction outlets).
Avoid fittings that could cause an air trap.
Pool cleaner suction fittings must conform to applicable International
Association of Plumbing and Mechanical Officials (IAPMO®) standards.
Figure 1. Number of Suction Outlets Per Pump
Section 2. General Description
2.1 Introduction
This manual contains information on the proper installation, operation, and
maintenance of the Polaris PB4-60 pump. Procedures in this manual must be
followed exactly. To obtain additional copies of this manual contact Zodiac
Pool Systems, Inc. (“Zodiac”) at 800.822.7933. For address information, see
the back cover of this manual.
2.2 Description
The Polaris booster pump, PB4-60, supplies high-pressure water to the Polaris
pool cleaner to optimize cleaner efficiency. The pump is not self-priming and
should only be used when the pool filtration pump is on.
CAUTION
Running the booster pump without a filtration pump will damage the booster
pump. Improper operation of the booster pump will void the warranty.
2.3 Preparation
- Upon receipt of the pump, check the carton for damage. Open the carton and check the pump for concealed damage, such as cracks, dents or a bent base. If damage is found, contact the shipper or distributor where you purchased the pump.
- Inspect the contents of the carton and verify that all the parts are included. See Section 7.1, Replacement Parts List.
Section 3. Installation
3.1 Electrical Installation
3.1.1 Voltage Checks
The correct voltage, as specified on the pump data plate, is necessary for
proper performance and long motor life. The incorrect voltage will decrease
the pump’s ability to perform and could cause overheating, reduce the motor
life, and result in higher electric bills.
It is the responsibility of the electrical installer to provide data plate
operating voltage to the pump by ensuring proper circuit sizes and wire sizes
for this specific application.
The National Electrical Code® (NEC®, NFPA-70®) requires all pool pump circuits
be protected with a Ground Fault Circuit-Interrupter (GFCI). Therefore, it is
also the responsibility of the electrical installer to ensure that the pump
circuit is in compliance with this and all other applicable requirements of
the National Electrical Code (NEC) and any other applicable installation
codes.
** CAUTION
Failure to provide data plate voltage (within 10%) during operation will cause
the motor to overheat and void the warranty.
3.1.2 Bonding and Grounding**
- The motor frame must be grounded to a reliable grounding point using a solid copper conductor, No. 8 AWG (8.4mm2) or larger. In Canada, No. 6 AWG (13.3mm2) or larger must be used. If the pump is installed within five 5 feet (1,5 meter) of the inside walls of the swimming pool, spa, or hot tub, the motor frame must be bonded to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within five (5) feet (1,5 meter) of the inside walls of the swimming pool, spa, or hot tub.
- Bond the motor using the provided external lug.
WARNING
To avoid the risk of property damage, severe personal injury, and/or death,
always disconnect the power source before working on a motor or its connected
load.
WARNING
To avoid the risk of property damage, severe personal injury, and/or death,
make sure that the control switch or time clock is installed in an accessible
location so that in the event of an equipment failure or loose plumbing
fitting the equipment can be turned off. This location must not be in the same
area as the pool pump, filter, and other equipment.
CAUTION
The pump must be permanently connected to a dedicated electrical circuit. No
other equipment, lights, appliances or outlets may be connected to the pump
circuit, with the exception of devices that may be required to operate
simultaneously with the pump, such as a chlorinating device or heater.
3.2 Electrical
Motor Rating
HP| S.F| RPM| VOLTS| S.F. AMPS
3/4| 1.5| 3450| 230/115,60Hz.1Ph| 6.4/12.8
Table 1. Maximum Wire Size and Overcurrent Protection
**MAXIMUM WIRE SIZE AND MAXIMUM OVERCURRENT PROTECTION***
Distance from Sub-Panel| 0-50 feet (15 meters)| 50-100 feet
(15-30 meters)| 100-200 feet (30-60 meters)
Pump Model| Branch Fuse AMPs
Class: CC, G, H, J, K, RK, or T
230 VAC 115 VAC| Voltage
208-230 VAC 115 VAC| Voltage
208-230 VAC 115 VAC| Voltage
208-230 VAC 115 VAC
FB4-60| 15A| 20A| 14 AWG
(2.1mm2)| 12 AWG
(3.3mm2)| 12 AWG
(3.3mm2)| 10 AWG
(5.3mm2)| 10 AWG
(5.3mm2)| 10 AWG
(5.3mm2)
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in the branch circuit. All National Electrical Code® (NEC®) and local codes must be followed. The table shows minimum wire size and branch fuse recommendations for a typical installation per NEC.
3.2.1 Electrical Wiring
-
The pump motor must be securely and adequately grounded using the green screw provided. The ground before attempting to connect to an electrical power supply. Do not ground to a gas supply line.
-
Wire size must be adequate to minimize voltage drop during the start-up and operation of the pump. See Table 1 for wire sizes.
-
Insulate all connections carefully to prevent grounding or short-circuits. Sharp edges on terminals require extra protection. To prevent wire nuts from loosening, tape them using a suitable, listed (UL®, ETL®, CSA®) electrical insulating tape. For safety, and to prevent the entry of contaminants, reinstall all conduit and terminal box covers. D o not force connections into the conduit box.
-
To configure the internal wiring of the pump motor for the correct voltage, refer to the diagram on the motor data plate.
-
The starting current of the booster pump motor may exceed 15 amps on a 115 VAC voltage line. It is recommended that a 20 amp service breaker be used for the pump connected to 115 VAC.
-
The booster pump motor is factory wired for 230 volts but can be wired for either 115 or 230 volts. To rewire to 115 volt, follow the instructions on the nameplate located on the back of the motor or the sizing plate on the side of the motor.
-
A separate time clock (in addition to the filtration system time clock) is recommended to control the On/Off functions of the booster pump. A manual switch can also be used.
-
If a time clock is used, set it to turn the pump on at least half an hour after the pool filtration pump is turned on, and turn the pump off at least half an hour before the filtration pump shuts off. Periodically check the time clock settings to make sure they are properly synchronized.
3.3 Plumbing
CAUTION
Be careful not to overtighten any pipe fitting on the inlet or outlet of the
booster pump. Overtightening can cause the housing to crack.
3.3.1 Requirements
The Polaris Booster Pump requires a dedicated return line. Plumb the booster
pump into the system so that it always receives flow from the filtration pump.
To ensure the proper function of the pump and the cleaner, refer to Figure 2
and adhere to the following guidelines for specific equipment.
-
Plumb the dedicated line upstream of all air-inducing equipment.
-
If a heater is installed on the system, tap the inlet for the booster pump into the return line downstream and at least three (3) feet (1 meter) from the heater discharge. See Figure 2. Do not tap the booster pump inlet into the three-foot (1 meter) section of the heat sink pipe that comes directly out of the heater. Figure 2. Typical Equipment Layout
-
Some solar heating systems utilize the entire water flow when the panels are being purged of air. If the pump is installed in a non-flow pipe during solar panel purges, install an automatic override to shut off the pump.
-
Plumb the booster pump inlet higher, upstream, and as far away as possible from a chlorinator.
3.3.2 Pipe Sizing
- Use rigid PVC pipe with a minimum diameter of 3/4″, 1-1/2″ is recommended, for the dedicated return line. Flexible PVC piping is not recommended for the dedicated pool return line underground as it can be damaged by expansion and movement caused by the surge of pump pressure. Figure 3. Preferred Plumbing Configuration Figure 4. Alternate Plumbing Configuration
- The booster pump inlet connection line should be at least 3/4″ pipe. The Softube Quick Connect fittings are designed to work with the Polaris reinforced hose (part #P19) only.
- Do not tap into the top of a horizontal line.
- Use 90° street ells to minimize bends and loops in the Polaris reinforced hose.
3.3.3 Pump Location
-
Zodiac Pool Systems, Inc. recommends installing the pump within one 1 foot (30 cm) above the water level. The pump should not be elevated more than a few feet above the water level of the pool.
-
If the pump is located below water level, isolation valves must be installed on both the suction and return lines to prevent the backflow of pool water during any routine or required servicing.
WARNING
Some Safety Vacuum Release System (SVRS) devices are not compatible with the installation of check valves. If the pool has an SVRS device, be sure to confirm that it will continue to safely operate when any check valves are installed. -
The pump and other circulation equipment must be located more than 5 feet (1,5 meters) from the water. Choose a location that will minimize turns in the piping.
NOTE In Canada, the pump must be located a minimum of 3.0 meters [approximately 10 feet] from the water (CSA C22.1). -
The pump must be placed on a solid foundation that will not vibrate. To further reduce the possibility of vibration noise, bolt the pump to the foundation.
NOTE Zodiac® recommends bolting the pump directly to the foundation. -
The pump foundation must have adequate drainage to prevent the motor from getting wet. The pump needs to be protected from the rain and sun.
-
Proper ventilation is required for the pump to operate normally. All motors generate heat that must be removed by providing proper ventilation.
-
Provide access for future service by leaving a clear area around the pump. Allow plenty of space above the pump for servicing.
-
If the equipment is undercover, provide adequate lighting.
3.3.4 Install the Pump
-
Mount the pump using two (2) concrete expansion anchors to ensure stability.
-
Apply four (4) to six (6) wraps of Teflon® tape to the tapered thread of the connecter barb. See Figure 5 (a).
CAUTION
Pipe dope should NEVER be used on barb threads. Pipe dope will severely weaken the plastic, causing leakage and may cause the plastic to fracture. DO NOT OVERTIGHTEN. -
Thread and tighten the tapered thread of the connector barb into the pump port on the pump body. See Figure 5 (b).
Figure 5. Prep and install Quick Connect barb and connector nut
Figure 6. Tighten Connector Nut to Secure Hose -
Trim reinforced hose to the required length. Make sure the cut is clean and square. Avoid unnecessary loops or bends in the hose.
-
Slide connector nut onto the trimmed end of the hose with a threaded end toward the cut end of the hose. See Figure 5 (c).
-
Apply water to connector barb to help hose slide over barbs. Push trimmed edge of hose fully onto the connector barb. See Figure 5 (d).
-
Slide/Rotate the connector nut to the barb to engage threads correctly, do not cross-thread the connector nut. Tighten the connector nut until threads are no longer visible (gap about 1/8″ or just less than the width of two dimes), or until it touches the barb face. See Figure 6.
3.3.5 Installation Recommendations
-
1. If the pump is located below water level, isolation valves must be installed on both sides of the pump to prevent the backflow of pool water during any routine or required servicing.
-
To help prevent difficulty in priming, install the suction pipe without high points (above the inlet of the pump – inverted “U”s in plumbing), which can trap air.
-
The piping must be well supported and not forced together where constant stress will be experienced.
-
Always use properly sized valves. Jandy® Pro Series diverter valves and ball valves typically have the best flow capabilities.
Figure 7. Complete Installation -
Use the fewest fittings possible. Every additional fitting has the effect of moving the equipment farther away from the water.
NOTE If more than 10 suction fittings are needed, the pipe size must be
increased.
3.3.6 Check the Water Flow
NOTE This pump must have minimum outlet pressure of 45 psi. The lower
pressure may cause an overcurrent motor condition. After the system is
plumbed, verify water flow to the booster pump by disconnecting the inlet
supply line at the booster pump and then turning on the filtration pump. Water
should flow from the line.
If there is no water flow, check the following:
- Verify that the installation is correct. Refer to Figure 6.
- Use smaller eyeball fittings in the pool return lines or plug a return line. Once the flow is established, the pump is ready for operation.
3.3.7 Conduct Pressure Test
WARNING
When pressure testing a system with water, air is often trapped in the system
during the filling process. This air will compress when the system is
pressurized. Should the system fail, this trapped air can propel debris at a
high speed and cause injury. Every effort to remove trapped air must be taken,
including opening the bleed valve on the filter and loosening the pump basket
lid on the filter pump while filling the pump.
WARNING
Trapped air in the system can cause the filter lid to be blown off, which can
result in death, serious personal injury, or property damage. Be sure all air
is properly out of the system before operating. DO NOT USE COMPRESSED AIR TO
PRESSURE TEST OR CHECK FOR LEAKS.
WARNING
When pressure testing the system with water, it is very important to make sure
that the pump basket lid on the filter pump is completely secure.
WARNING
Do not pressure test above 35 PSI. Pressure testing must be done by a trained
pool professional. Circulation equipment that is not tested properly can fail,
which could result in severe injury or property damage.
- Fill the system with water, using care to eliminate trapped air.
- Pressurize the system with water to no more than 35 PSI.
- Close the valve to trap pressurized water in the system.
- Observe the system for leaks and/or pressure decay.
- For technical support, contact Zodiac® technical support at 800.822.7933.
Section 4. Operation
4.1 Start-up
CAUTION
Never run the booster pump without water. Running the pump “dry” for any
length of time can cause severe damage to both the pump and motor and will
void the warranty.
CAUTION
Never run the booster pump without the cleaner connected. Running the pump
without the cleaner connected will cause damage to the pump impeller and will
void the warranty.
If this is a new pool installation, make sure all piping is clear of
construction debris and has been properly pressuring tested. The filter should
be checked for proper installation, verifying all connections and clamps are
secure according to the manufacturer’s recommendations.
WARNING
To avoid the risk of damage or injury, verify that all power is turned off
before starting this procedure.
- Turn the filtration pump ON.
- Open the filter pressure release to relieve the system pressure until water comes out.
- If the filter pump is located below the water level of the pool, opening the filter pressure release valve will prime the pump with water.
- Once all the air has left the filter, close the pressure release valve.
- Turn on the power to the booster pump. Then turn on the booster pump.
- The booster pump should prime. The time it takes to prime will depend on the elevation and length of pipe used on the suction supply pipe. See Section 3.3.6 for proper elevation and pipe size.
- If the booster pump does not prime and all the instructions to this point have been followed, check for a suction leak.
Section 5. Maintenance
5.1 Winterizing the Pump
CAUTION
The pump must be protected when freezing temperatures are expected. Allowing
the pump to freeze will cause severe damage and void the warranty.
CAUTION
Do not use antifreeze solutions in the pool, spa, or hot tub systems!
Antifreeze is highly toxic and may damage the circulation system. The only
exception to this is Propylene Glycol. For more information see your local
pool/spa supply store or contact a qualified swimming pool service company.
-
Drain all water from the pump, system equipment, and piping.
-
Remove the drain plug. Store the drain plug in a safe location and reinstall it when the cold weather season is over. Do not lose the o-ring. (Drain Plug with O-ring Set, R0537000).
-
Keep the motor covered and dry.
NOTE Covering the pump with plastic will create condensation, and this moisture will damage the pump. The best way to protect your pump is to have a qualified service technician or electrician properly disconnect the electrical wiring at the switch or junction box. Once the power is removed, the two (2) quick connect fittings can be loosened and the pump stored indoors. For safety, and to prevent the entry of contaminants, reinstall all conduit and terminal box covers. -
When the system is reopened for operation, make sure all piping, valves, wiring, and equipment are in accordance with the manufacturer’s recommendations. Pay close attention to the filter and electrical connections.
-
The pump must be primed prior to start; refer to Section 4.1, Start-up.
Section 6. Product Specifications and Technical Data
6.1 Replacement Parts List To order or purchase parts for Polaris® pumps, contact your nearest Zodiac® dealer. If they cannot supply you with what you need, contact Zodiac technical support at 800.822.7933 or www.zodiacpoolsystems.com.
No. …………………………………………………………….Description | Qty | No | Comments |
---|---|---|---|
1 | Replacement Motor for Booster Pump | 1 | P61 |
2 | 0-Ring, Backplate, PB4-60 | 1 | R0536600 |
3 | Seal, Ceramic and Spring | 1 | R0445500 |
4 | Impeller, PB4-60 | 1 | R0536400 |
5 | Volute, PB4-60 | 1 | R0536300 |
6 | Bolts with Washers and Nuts | 6 | R0536900 |
7 | Drain Plug with 0-Ring, Common | 1 | R0537000 |
8 | Base, Booster, PB4-60 | 1 | R0537100 |
9 | Bolts and Washers, Stainless, Motor, PB4-60 | 4 | R0536800 |
10 | Quick Connect Install Kit | 1 | R0617100 |
reinforced hose and 4 ea Quick Connect fittings.
11| Quick Connect Fittings| 4| R0621000| Comes with 4ea Quick Connect
Fittings and Installation Instructions.
12| Pump Hose 6FT Reinforced| 1| P19|
13| Backplate PB4-60| 1| R0536700| Includes Seal and Backplate 0-ring.
6.2 Polaris PB4-60 Booster Pump Exploded View
Figure 11. Polaris PB4-60 Booster Pump Exploded View
6.3 Pump Dimensions NOTE When installing the pump, leave a minimum of 2.0
feet (60 cm) of clearance above the pump for service.
Figure 12. Polaris PB4-60 Booster Pump Dimensions
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
©2017 Zodiac Pool Systems, Inc. ZODIAC is a registered trademark of Zodiac
International, S.A.S.U., used under license. Polaris® and the Polaris
3-wheeled cleaner®
design are registered trademarks of Zodiac Pool Systems, Inc.
All trademarks referenced herein are the property of their respective owners.
H0399500 REV E
LIMITED WARRANTY
GAS POOL AND SPA HEATERS
Models: 106A, 156A, 206A, 266A, 336A, 406A, 207A, 267A, 337A, 407A
SCOPE OF WARRANTY
Raypak, Inc. (Raypak) warrants to the original owner that the above model
gas pool and spa heater (the “Heater”) when installed in the contiguous 48
states of the United States of America with a pool or spa by a properly
licensed installer will be free from defects in materials and workmanship
under normal use and service for the Applicable Warranty Period. Under this
Limited Warranty, Raypak will, at its option, repair or furnish a replacement
for any defective part of the HEATER. The repair or replacement will be
warranted for only the unexpired portion of the original Applicable Warranty
Period.
EFFECTIVE DATE
The Effective Date of Warranty coverage is the date of original
installation if properly documented; otherwise, it is the date of manufacture
plus 30 days. All Applicable warranty Periods specified in this Limited
Warranty are measured from the Effective Date.
APPLICABLE WARRANTY PERIOD
If the HEATER is installed with a pool or spa, the Applicable Warranty Period
is one (1) year from the Effective Date, parts, and labor, for the HEATER and
component parts. LABOR AND SHIPPING COSTS
This Limited Warranty covers the reasonable cost of labor for repairs or
replacements covered by this Limited Warranty, provided that said repairs or
replacements are erformed by a Raypak designated service provider during the
Applicable Warranty Period and Raypak has pre-authorized said repair or
replacement. This Limited Warranty does not cover any travel time or other
labor costs. Furthermore, this Limited Warranty does not cover any shipping
costs to and from the service provider or to or from the installation site.
All of the foregoing costs and expenses are your responsibility.
WARRANTY EXCLUSIONS
This Limited Warranty does NOT apply;
- if the Heater has been moved from its original place of installation, or if the original owner no longer owns the property where the original installation was made;
- if the Heater is not properly installed with a pool or spa by a qualified licensed installer in accordance with applicable local codes and ordinances, good trade practices, and the manufacturer’s installation instructions;
- if the rating plate(s) or serial number(s) are altered or removed;
- if the Heater is modified in any way, or non-factory authorized accessories or other components are used in conjunction with the Heater;
- to damage, malfunctions, or failures resulting from failure to properly install, operate or maintain the Heater in accordance with the manufacturer’s instructions;
- to damage, malfunctions, or failures resulting from abuse, the act of nature, accident, fire, flood, freeze, lightning, or the like;
- to damage, malfunctions, or failures resulting from connected system control devices;
- performance problems caused by improper sizing of the Heater or electric service voltage, wiring, or fusing;
- use of any attachment, including without limitation, any energy-saving device not authorized by the manufacturer;
- to damage, malfunctions or failures resulting from misuse or neglect, including but not limited to, freeze-ups, operating the Heater with the cabinet door off, having flow restrictions or obstructions between the Heater outlet and the pool/spa, electrolysis due to an improperly installed salt chlorine generator, or not maintaining a proper chemical balance (PH level must be between 7.4 and 7.8 and total alkalinity between 100 and 150 PPM. Total dissolved solids (TDS) must be no greater than 3000 PPM. In saltwater chlorinated pools, TDS must be no greater than 6000 PPM).
Catalog Number: 6000.95
Effective 7/01/13
HOW TO MAKE A WARRANTY CLAIM
You should immediately notify your dealer and provide proof of purchase
model number serial number and date of installation. Your dealer will contact
Raypak for instructions regarding the claim and to determine the location of
the nearest authorized service center. If the dealer is not available, please
contact Raypak warranty service at
805-278-5300. When making a claim
please be ready to supply the model number, serial number, date of the
original installation, and a description of the problem. Proper authorization
MUST be obtained PRIOR to any repairs for the Limited Warranty to apply. This
Limited Warranty is VOID if the Heater is repaired or altered in any way by
ANY persons or agencies other than those authorized by Raypak. Raypak reserves
the right at all times to inspect, or require the return of, the defective
Heater or component part and to verify warranty overage at its factory.
EXCL USIVE WARRANTY-LIMITATION OF LIABILITY
THE LIMITED WARRANTY IS THE ONLY WARRANTY GIVEN BY RAYPAK IN CONNECTION
WITH THE HEATER AND ITS COMPONENT PARTS. NO ONE IS AUTHORIZED TO MAKE ANY
OTHER WARRANTIES ON RAYPAK’S BEHALF. ANY IMPLIED WARRANTIES, INCLUDING
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND
THE APPLICABLE WARRANTY PERIOD SPECIFIED ABOVE. RAYPAK’S SOLE LIABILITY WITH
RESPECT TO ANY DEFECT SHALL BE AS SET FORTH IN THIS LIMITED WARRANTY. IT IS
AGREED THAT RAYPAK SHALL HAVE NO LIABILITY WHETHER UNDER THIS LIMITED WARRANTY
OR IN CONTRACT, TORT OR NEGLIGENCE, OR OTHERWISE FOR CLAIMS FOR SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING NO LIABILITY FOR DAM GE FROM
WATER LEAKAGE), ALL OF WHICH ARE EXPRESSLY EXCLUDED. SOME STATES DO NOT ALLOW
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR FOR THE EXCLUSION OF
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY
NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND
YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
We suggest you immediately record the model and serial number and date of the
original installation and retain this Limited Warranty Certificate in the
event warranty service is needed.
DO NOT RETURN THIS DOCUMENT TO RAYPAK. KEEP IT WITH YOUR POOL HEATER OR
BUSINESS RECORDS.
Name of Owner | Name of Installer |
---|---|
Owners Address | Installers Address |
Date of Pool Heater Installation | Telephone Number of Installer |
Model Number of Your Pool Heater | Serial Number of Your Pool Heater |
RAYPAK, INC., 2151
Eastman Avenue, Oxnard, CA 93030
805-278-5300 FAX
800-872-9725
References
- Home | Polaris Pool
- Home | Polaris Pool
- NFPA | The National Fire Protection Association
- P65Warnings.ca.gov
- Residential Pool Supplies and Pool Solutions | Pentair
- Residential Pool Supplies and Pool Solutions | Pentair
- Home | Polaris Pool
- Zodiac Pool Systems United States | Zodiac Pool Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>