TEKTELIC T0006955 eDoctor User Guide
- May 15, 2024
- TEKTELIC
Table of Contents
TEKTELIC T0006955 eDoctor
Specifications
- Use environment: Indoor professional use only
- Size: eDoctor: 105 mm x 38 mm x 18 mm, Chest Band: up to 1450 mm x 2 mm x 30 mm
- Weight: doctor: 53.8 g (with battery), Chest Band: 28.8 g
- Power source: Battery operated (one CR2477)
- Network technology/Frequency band: LoRaWAN with different regional variants
- Air interface: LoRa
- Battery lifetime: 2-3 months
- Maximum transmit power: 14 dBm
- Number of indicator LEDs: 2 (one red and one green)
- Number of push buttons: 2 (one blue and one green)
- Sensing functions: Skin temperature, heart rate, respiratory rate, chest expansion, body position, and physical activity status
Product Description
Overview
The doctor health and fitness monitor is a small, light, battery-powered LoRaWAN sensor worn around the chest to monitor and report skin temperature, heart rate, respiratory rate, chest expansion, body position, physical activity status, and battery life periodically.
Interfaces
- The eDoctor features two indicator LEDs (green and red) on the front and two push buttons (blue and green) on the top.
- It also has two strap snaps on the back for attachment to an adjustable strap for varying chest sizes.
Setup and Operation
- The following items are included with each sensor:
Safety Precautions
- The following safety precautions should be observed:
Unpacking and Inspection
- Inspect the shipping carton and report any significant damage to TEKTELIC.
- Unpacking should be conducted in a clean and dry location.
- Do not discard the shipping box or inserts as they will be required if a unit is returned.
FAQ
Q: How often does the eDoctor send uplinks?
- A: The eDoctor is configured to send uplinks every 5 minutes by default while being worn.
Revision History
Revision | Issue Date | Editor | Comments |
---|---|---|---|
0.1 | Nov 4, 2020 | Reza Nikjah | Initial release. |
0.2 | Feb 2, 2021 | Reza Nikjah | Minor edits. |
Added Mobile Application view.
0.3| June 6, 2023| Shania Stewart| · Updated product name and product code.
· Expanded on product specifications and added product images.
· Updated the instructions for use and added troubleshoot information.
1.0| Aug 4, 2023| Shania Stewart| · Updated product code to support Rev C modules.
· Corrected T-code in document footer.
· Added additional setup information and safety precautions.
· Added regulatory compliance statements.
1.1| Aug 22, 2023| Shania Stewart| · Minor edits.
1.2| Aug 23, 2023| Shania Stewart| · Edited wording and added
additional safety warnings based on feedback.
1.3| Aug 23, 2023| Shania Stewart| · Added tool requirement.
Product Description
Overview
- The eDoctor health and fitness monitor is a small, light, battery powered LoRaWAN sensor that is worn around the chest (upper torso) to monitor and periodically report the user’s skin temperature, heart rate, respiratory rate, chest expansion, body position, and their physical activity status.
- The eDoctor also measures and periodically reports the remaining battery lifetime.
- The eDoctor is configured to send uplinks every 5 minutes by default while the device is being worn.
- For more information on all the available Over-the-Air configuration options, see the eDoctor Technical Reference Manual located on the TEKTELIC support portal.
Specifications
- The eDoctor specifications are listed in Table 1-1.
Table 1-1: eDoctor Specifications
Parameter | Specification |
---|---|
Use environment | Indoor professional use only |
Size | eDoctor: 105 mm x 38 mm x 18 mm |
Chest Band: up to 1450 mm x 2 mm x 30 mm
Weight| eDoctor: 53.8 g (with battery)
Chest Band: 28.8 g
Power source| Battery operated (one CR2477)
Network technology/Frequency band| LoRaWAN with different regional variants
Air interface| LoRa
Battery lifetime| 2-3 months
Maximum transmit power| 14 dBm
Number of indicator LEDs| 2 (one red and one green)
Number of push buttons| 2 (one blue and one green)
Sensing functions| Skin temperature, heart rate, respiratory rate, chest
expansion, body position, and physical activity status
Interfaces
- Figure 1-1 shows the enclosure and external interfaces of the eDoctor. Two indicator LEDs (one green and one red) are present on the front of the enclosure, while two push buttons (one blue and one green) are accessible on the top of the enclosure.
- There are two strap snaps on the back of the enclosure so that the device can be attached to an adjustable strap for different chest sizes.
Setup and Operation
Included Product
- The following items are included with each sensor.
- An eDoctor sensor
- Adjustable chest strap
- Quick start guide
Safety Precautions
- The following safety precautions should be observed.
- The eDoctor strap is intended to be worn around the chest only.
- The eDoctor contains a lithium coin cell battery.
- CAUTION – Do not ingest battery, Chemical Burn Hazard.
- CAUTION – This product contains a coin cell battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
- CAUTION – Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
- CAUTION – Risk of fire or explosion if battery is replaced by an incorrect type.
Unpacking and Inspection
The following should be considered during the unpacking of a new eDoctor.
- Inspect the shipping carton and report any significant damage to TEKTELIC.
- Unpacking should be conducted in a clean and dry location.
- Do not discard the shipping box or inserts as they will be required if a unit is returned for repair or re-configuration.
Required Equipment
- A flat tool (e.g., a coin) is required to lock/unlock the battery lid located on the back of the device. No other special equipment or tools are required to power or operate the eDoctor.
Instructions for Use
- The eDoctor is shipped with a battery installed and an insulating sticker on the negative terminal of the battery to prevent device operation. Removing the sticker and re-inserting the battery will activate the device.
- After the sticker has been removed, the battery must be removed to turn off the device.
- Before activating the device, ensure that the eDoctor is provisioned on your LoRaWAN Network Server before proceeding with the instructions below.
- One way to provision your device is by downloading the TEKTELIC eDoctor Mobile App available on iOS and Android and following the app’s setup instructions.
- To activate the unit or to replace the battery when required, the following steps can be followed.
- Locate the battery lid on the back of the eDoctor. Rotate the lid counter clockwise using a flat tool (e.g., a coin) to unlock it, and then remove the battery lid from the device.
- Remove the battery from the battery holder. For activation of a newly received device, peel the sticker off the negative terminal of the battery. For battery replacement, use only an approved CR2477, 3V Lithium Manganese Dioxide coin cell.
- Place the battery inside the eDoctor battery compartment so that the positive terminal of the battery is visible after insertion. Align the battery lid so that the arrow is pointing to the bottom left, and turn the lid clockwise with a flat tool (e.g., a coin) until there is a click and noticeable resistance to further rotation to lock it in.
- After a few seconds, the LEDs on the eDoctor should start blinking, showing that the eDoctor is trying to join the LoRaWAN network.
- The LEDs will stop blinking once the eDoctor has joined the LoRaWAN network, but you do not need to wait for this to happen before proceeding to step 5.
- Attach the eDoctor to the adjustable chest strap using the snaps located on both the device and the strap. Make sure that the two metal probes in the middle of the device go through the holes in the strap.
- Wear the eDoctor with the strap around the chest. It is meant to be worn on the upper torso with the device centered on the patient’s chest. Make sure to wear the device so that the two push buttons face upwards.
- Note: Adjust the strap length so that the eDoctor sits comfortably on the chest without sagging.
- Try taking shallow and deep breaths to ensure that the strap is adjusted properly.
Troubleshooting
- If the device remains blinking for more than two minutes (see step 4 in Section 0), then follow these troubleshooting actions.
- Ensure the device is provisioned on the Network Server
- Ensure the local LoRaWAN Gateway has also been provisioned on the Network Server
- Ensure the local LoRaWAN Gateway is online and within range of the device
- If you have questions about using this device, please refer to the support portal: https://support.tektelic.com/portal/en/
Compliance Statements
Federal Communications Commission
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
To comply with FCC exposure limits for general population / uncontrolled
exposure, this device has lowered its maximum power to comply with SAR limits
for wearable devices and must not be co-located or operating in conjunction
with any other transmitter.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Innovation, Science and Economic Development Canada This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
- California Proposition 65: WARNING: This product can expose you to chemicals including lead, nickel, and carbon black, which are known to the State of California to cause cancer, birth defects or other reproductive harm.
- For more information, go to www.P65Warnings.ca.gov.
- © 2023 TEKTELIC Communications Inc., all rights reserved.
- All products, names, and services are trademarks and registered trademarks of their respective companies.
- TEKTELIC Communications Inc.
- 7657 10th Street NE
- Calgary, AB, Canada T2E 8X2
- Phone: (403) 338-6900
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>