renu Cold Stoic 3.0 Plunge
GETTING TO KNOW YOUR COLD STOIC 3.0
Remove and discard external packaging
REMOVE ALL ACCESSORIES
- Remove foot stool and all accessories from tank.
- Remove Back Vent Panel by lifting up and swinging the bottom edge out. Remove all loose accessories and packing from Mechanics Bay.
PLACEMENT & VENT CLEARANCE
- Place your Cold Stoic 3.0 in a water-safe location, ensuring adequate clearance to allow for hot air venting and access to the filter and drain outlet.
- Position the power cord in one of the provided grooves on the bottom of the tank
FILL YOUR COLD STOIC 3.0
- Fill tub to within 6” to 8” from top of tank
- Larger users may need a lower initial water level to avoid spillover
PLUG IN YOUR COLD PLUNGE
- Be sure to reset the Ground Fault Circuit Interrupter (GFCI) on the power plug by pressing the RED button if the yellow TEST button is triggered
PRIMING THE CIRCULATION PUMP
If the display is upside down, touch the “Screen Flip” icon”
Before first use, the system will enter Priming mode to validate all functions of your cold plunge.
- Touch the “Circ” button once to start the pump. Be sure the water level is high enough to cover the entire filter intake cover.
- Priming Mode takes 3 to 5 minutes to complete. Check the plumbing in the Mechanics Bay to ensure there are no leaks.
SETTING THE TIME
-
The system will remind you to set the time on startup. Touch the ‘X’ button to clear the message.
-
From the home screen, touch the Right Arrow, then scroll to the “settings” button.
-
In the Settings menu, touch the ‘Time’ field.
-
Scroll to the correct time, and touch the SAVE Checkmark to complete.
-
Touch the Back Arrow to return to the Home screen
SETTING THE TEMPERATURE
-
The system may take a few more seconds to display the current water temperature. To change the target temperature, touch the Temperature display, and scroll the selector to the right or left until the desired temperature is selected.
-
You may use the Temperature Shortcut buttons to go directly to 45 deg F or 104 deg F
-
In cooling mode, the water temperature will drop at a rate between 1.5 to 3 degrees F per hour. In Heating mode the temperature will rise at a rate between 4 and 6 degrees F per hour.
ENJOY YOUR COLD PLUNGE
- To enable wireless control of your Cold Stoic 3.0, follow the ‘CONTROL SPA Gateway Ultra Quick Start Guide’ included with your WiFi receiver.
- Some condensation may develop in the Mechanics Bay while at low temperatures, and a small amount of water will normally drain out the bottom of the Back Vent in very humid conditions.
NOTICE: Read the User’s Manual for important safety information and warnings before using this product!”
|
Website Direct: maintenance items
---|---
MAINTENANCE SCHEDULE
-
The in-tank pre-filter should be cleaned every 2 to 4 weeks, or if you notice a decrease in the Ozone Sanitizer bubbles, depending on how often you use your Cold Stoic 3.0.
-
To clean the filter, remove the filter intake cover by popping it out of the filter housing, and unscrew the blue filter cartridge. Spray the filter pleats with a Spa Filter Cleaner, let it soak for 15 minutes, then rinse thoroughly under clean water. The filter should be replaced after 3 to 6 months, or when the filter is no longer working.
-
The XL filter should be cleaned and the water changed about every 3 to 6 months, depending on how often you use your Cold Plunge. To remove the filter, unplug the power cord from the wall, the open the right-side vent or back vent panel.
-
Turn off the two red-handled ball valves on the plumbing by rotating the red handle 90 degrees, so it is perpendicular to the pipe. Then, use the included Filter Housing Wrench to carefully unscrew the blue filter bucket from the housing. Some water may spill out when unscrewed. Remove the filter cartridge and follow the above filter cleaning instructions.
-
After the XL Filter Cartridge has been cleaned and thoroughly rinsed, replace it into the blue filter bucket, and carefully screw it back onto the housing.
DO NOT OVERTIGHTEN!
DO NOT USE THE WRENCH! TIGHTEN BY HAND! -
Open both red-handled ball valves, and plug the power cord in to initiate Priming Mode.
-
It is recommended to replace the XL Filter Cartridge about once every 6 to 12 months or as needed due to use.
-
Water Change: The water should be drained, tank cleaned and sanitized, and refilled every 3 – 6 months.
DRAINING YOUR COLD STOIC 3.0
- To drain your tank, first un-plug the power cord from the outlet, then follow the instructions on the Power Drain inside the rear vent panel (if equipped), or use the included Water Bug sump pump to remove the water from the tank.
- Refill the tank with clean water, and then plug the power cord into the outlet.