SAFRAN 8226 GNSS Surge Suppressor Installation Guide
- August 20, 2024
- Safran
Table of Contents
Installation Guide
ELECTRONICS & DEFENSE
Model 8226 GNSS
Surge Suppressor
8226 GNSS Surge Suppressor Installation Guide
Part Number 8226-0002-0050, Revision: 8
Introduction
Safran recommends the use of an inline coaxial protector for all products
connected to an outside GNSS antenna.
Safran offers the Model 8226 GNSS Antenna Surge Suppressor to protect a
connected GNSS receiver from damaging voltages occurring on the antenna coax
cable. Voltages exceeding the impulse suppressor trip point are shunted to the
system ground. The Model 8226 is designed to withstand multiple surges.
Installation
2.1. Mounting Bracket Installation
Install the suppressor indoors, preferably where the coax enters the building.
Connect the largest- gauge grounding wire available to the mounting bracket,
using the M8 attachment screw; see Fig. 2: 2.2. Grounding Plate
Installation
Optionally, the suppressor can be mounted to a grounding panel or bulkhead, as
shown in Fig. 3: Safran offers a Surge Protector Grounding Kit, part number
8226-0002-0600, that serves as a single point ground connection for the Model
8226 Surge Suppressor. The kit includes a copper grounding plate on melamine-
covered particle board, mounting hardware, copper strapping, strap clamps,
ground wire, a ground clap, copper paste, an appropriate mounting bracket, and
ancillary hardware. A single point ground system is recommended to provide
optimum protection from lightning strikes.
-
Mount the grounding panel indoors, preferably close to where the antenna coax enters the building and direct access to the system ground is available.
-
The grounding panel must be connected to a low impedance (both low resistance and low inductance) ground system to assure proper operation of the surge protection equipment.
To minimize the inductance between the ground plate and system ground inter connection, keep the copper grounding strap as straight as possible. -
Limit bends to a radius of 8 inches or larger. Thoroughly clean the copper panel to remove any oxidation or contaminants prior to installation. Apply the supplied copper paste to all junctions on the copper panel to maintain a low-impedance connection.
Each Model 8226 includes two clamp type male N connectors. These connectors
can be used to splice the Model 8226 into the antenna coax. The connectors are
compatible with CAL7xxx cable assemblies and Times Microwave LMR- 400
equivalent coax. Connector assembly instructions are shown below: 2.3.
Assembly Instructions, Type N Connectors, and Clamps
The instructions below apply to Type N Connectors, part number P051-0001-0100.
Using the manufacturer’s part list, verify that all the connector parts are
included. (See also connector diagram below.) 2.4. Cable Assembly
Instructions – Clamp
Step 1 Stripping Braid Wire
Strip the braid wire where the connectors will be installed. Strip the cable
as shown in illustration on the right; follow the cable stripping dimensions
asrecommended by the connector manufacturer.
Step 2 Nut, Washer, Gasket, and Clamp
Place all the parts in order and make sure the assembly direction is correct.
Step 3 Spreading Braid Wire and Stripping Inner Conductor
Fold the braid wire backward onto the braid clamp and make it spread evenly.
Step 4 Contact Pin Soldering
While soldering the contact pin, it must be soldered carefully, and the pin
must remain free of tin-solder.
Step 5 Fastening the Nut
Install metal screw onto nut, and spin into the connector body until hand-
tight. Use wrench and tighten the nut.
Document Revision History
Rev | Description | Date |
---|---|---|
A | Legacy documentation | |
B | Reformatted instructions for latest style standards. Made minor text edits | |
throughout. Added reference to Grounding Kit, 8226-0002-0600. | Feb-07 | |
C | Updated Figure 1 to accurately represent new hardware | June-09 |
D | Minor maintenance & adjustments made to reflect hardware changes (cable | |
jacket dimensions). | April-11 | |
E | Update Figure 1, additional minor document maintenance. | August-11 |
6 | Connector assembly instructions revised. | Sept 2015 |
7 | Changed arrestor model and instructions for grounding. Plus: Layout and | |
minor content modifications. | Nov-17 | |
8 | Switched to Safran branding. | July-24 |
Safran Technical Support
For technical support, product specifications, and additional documentation,
you can visit https://safran-navigation-timing.com/support-hub/ to submit a
support request.
Information furnished by Safran is believed to be accurate and reliable.
However, no responsibility is assumed by Safran for its use, nor for any
infringements of patents or other rights of third parties that may result from
its use. Safran reserves the right to make changes without further notice to
any products herein. Safran makes no warranty, representation or guarantee
regarding the suitability of its products for any particular purpose, nor does
Safran assume any liability arising out of the application or use of any
product or circuit, and specifically disclaims any and all liability,
including without limitation consequential or incidental damages. No license
is granted by implication or otherwise under any patent or patent rights of
Safran. Trademarks and registered trademarks are the property of their
respective owners. Safran products are not intended for any application in
which the failure of the Safran product could create a situation where
personal injury or death may occur. Should Buyer purchase or use Safran
products for any such unintended or unauthorized application, Buyer shall
indemnify and hold Safran and its officers, employees, subsidiaries,
affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and reasonable legal fees arising out of, directly or indirectly,
any claim of personal injury or death associated with such unintended or
unauthorized use, even if such claim alleges that Safran was negligent
regarding the design or manufacture of the part.
Safran Electronics & Defense
safran-navigation-timing.com
Part Number 8226-0002-0050
Documents / Resources
|
SAFRAN 8226 GNSS Surge
Suppressor
[pdf] Installation Guide
8226, 8226 GNSS Surge Suppressor, GNSS Surge Suppressor, Surge Suppressor,
Suppressor
---|---
References
- The World Leader in Resilient PNT - Safran - Navigation & Timing
- The World Leader in Resilient PNT - Safran - Navigation & Timing
- Support Hub - Safran - Navigation & Timing
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>