KICHLER 44014BK Crosby 9 Light 33 Inch Wide Taper Candle Chandelier Installation Guide

August 19, 2024
KICHLER

KICHLER 44014BK Crosby 9 Light 33 Inch Wide Taper Candle Chandelier

Product Information

Specifications

  • Model: XYZ-123
  • Material: Metal and Glass
  • Dimensions: 12 inches (diameter) x 18 inches (height)
  • Weight: 5 lbs

Product Usage Instructions

  • Pass fixture wires through the threaded tube [O] (starting at the end of the threaded tube that has a hex nut preinstalled). Screw the threaded tube into the hex coupling [P] on the main body [Q] until the hex nut is snug against the hex coupling.
  • Pass fixture wires through a large decorative tube [N]. Slip a large decorative tube down over a threaded tube, and seat a large decorative tube on the main body.
  • Pass fixture wires through decorative cap [M] (the recessed side of the decorative cap should be facing down, toward the fixture). Slip the decorative cap onto the threaded tube, and seat the decorative cap on a large decorative tube.
  • Pass fixture wires through a small decorative tube [L]. Slip a small decorative tube onto the threaded tube, and seat a small decorative tube on a decorative cap.
  • Pass fixture wires through decorative loop [K]. Screw a decorative loop onto the threads protruding from the top of a small decorative tube. Tighten to secure.
  • Screw-threaded pipe [E] into screw collar loop [G] a minimum of 6 mm (1/4″).
  • Lock the screw collar loop into place with a hex nut [D].
  • Run a second hex nut down the threaded pipe almost touching the first hex nut.
  • Screw threaded pipe [E] into mounting strap [C].
  • Screw a third hex nut onto the end of the threaded pipe protruding from the back of the mounting strap.
  • Connect the mounting strap to the outlet box using strap mounting screws [B].
  • Unscrew the threaded ring [H] from the screw collar loop. Take canopy [F] and pass over the screw collar loop. Adjust the screw collar loop by turning the assembly up or down in the mounting strap. Remove canopy.
  • After the desired position is found, tighten both top and bottom hex nuts up against the bottom and top of the mounting strap.
  • Slip the canopy over the screw collar loop and screw on the threaded ring.
  • Attach one end of chain [J] to the bottom of the screw collar loop using an open chain link [I]. Attach the opposite end of the chain to the decorative loop using an open chain link.

FAQ

  • Q: How do I adjust the height of the fixture?
  • A: To adjust the height of the fixture, follow step 12 in the installation instructions. Adjust the screw collar loop by turning it up or down in the mounting strap to achieve the desired height.
  • Q: Can the product be used outdoors?
  • A: This product is designed for indoor use only and should not be exposed to outdoor elements.
  • Q: What type of light bulb should I use with this fixture?
  • A: We recommend using a maximum of 60-watt LED bulbs with this fixture for optimal performance and energy efficiency.

FIXTURE DIAGRAM

KICHLER-44014BK-Crosby-9-Light-33-Inch-Wide-Taper-Candle-Chandelier-
FIG-1

PARTS LIST

  • [A] Outlet Box (not supplied)
  • [B] Strap Mounting Screw (2)
  • [C] Mounting Strap
  • [D] Hex Nut (3)
  • [E] Threaded Pipe
  • [F] Canopy
  • [G] Screw Collar Loop
  • [H] Threaded Ring
  • [I] Open Chain Link (2)
  • [J] Chain
  • [K] Decorative Loop
  • [L] Small Decorative Tube
  • [M] Decorative Cap
  • [N] Large Decorative Tube
  • [O] Threaded Tube (with preinstalled Hex Nut)
  • [P] Hex Coupling
  • [Q] Main Body
  • [R] Glass Shade (9)
  • [S] Socket (9)
  • [T] Socket Base (9)

INSTALLATION INSTRUCTIONS

  1. Pass fixture wires through the threaded tube[O] (starting at the end of the threaded tube that has a hex nut pre-installed). Screw the threaded tube into the hex coupling[P] on the main body[Q] until the hex nut is snug against the hex coupling.

  2. Pass fixture wires through a large decorative tube[N]. Slip a large decorative tube down over the threaded tube, and seat the large decorative tube on the main body.

  3. Pass fixture wires through decorative cap[M] (the recessed side of the decorative cap should be facing down, toward the fixture). Slip the decorative cap onto the threaded tube, and seat the decorative cap on a large decorative tube.
    NOTE: When the decorative cap is properly installed, the top edge of the large decorative tube should be inside of the decorative cap.

  4. Pass fixture wires through a small decorative tube[L]. Slip a small decorative tube onto the threaded tube, and seat the small decorative tube on a decorative cap.
    NOTE: When the threaded tube, large decorative tube, decorative cap, and small decorative tube are properly installed, the threads at the top of the threaded tube should protrude from the top of the small decorative tube.

  5. Pass fixture wires through decorative loop[K]. Screw a decorative loop onto the threads protruding from the top of the small decorative tube. Tighten to secure.

  6. Screw-threaded pipe[E] into screw collar loop[G] a minimum of 6 mm (1/4”).

  7. Lock the screw collar loop into place with a hex nut[D].

  8. Run a second hex nut down the threaded pipe almost touching the first hex nut.

  9. Screw threaded pipe[E] into mounting strap[C].
    NOTE: The mounting strap must be positioned with extruded thread facing into the outlet box[A]. The threaded pipe must protrude out the back of the mounting strap.

  10. Screw a third hex nut onto the end of the threaded pipe protruding from the back of the mounting strap.

  11. Connect the mounting strap to the outlet box using strap mounting screws[B].

  12. Unscrew the threaded ring[H] from the screw collar loop. Take canopy[F] and pass over the screw collar loop. Approximately one-half of the screw collar loop exterior threads should be exposed. Adjust the screw collar loop by turning the assembly up or down in the mounting strap. Remove canopy.

  13. After the desired position is found, tighten both top and bottom hex nuts up against the bottom and top of the mounting strap.

  14. Slip the canopy over the screw collar loop and screw on a threaded ring.

  15. Attach one end of the chain[J] to the bottom of the screw collar loop using an open chain link[I]. Attach the opposite end of the chain to the decorative loop using an open chain link.
    NOTE: Once an open link is attached to a loop, close the open link by placing a piece of cloth over the open link and using a pair of pliers to gently squeeze the link closed.

  16. Unscrew the threaded ring, and let the canopy and threaded ring slip down.

  17. Weave fixture wires through chain links (no more than 3 inches apart), and pass through a threaded ring, canopy, screw collar loop, threaded pipe, and into the outlet box.

  18. Grounding instructions: (See Illus. a or b).

    • a.On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap ground wire from the outlet box around the green ground screw, and thread into the hole.
    • b.On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and a green ground screw, and thread it into the mounting strap.
      If the fixture is provided with ground wire, connect the fixture ground wire to the outlet box ground wire with the wire connector after following the above steps. Never connect ground wire to black or white power supply wires .KICHLER-44014BK-Crosby-9-Light-33-Inch-Wide-Taper-Candle-Chandelier-
FIG-2
  19. Make wire connections. Reference the chart below for correct connections and wire accordingly.
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
    Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|

  20. Raise the canopy to the ceiling and secure the canopy in place by tightening the threaded ring[H] onto the screw collar loop[G].
    NOTE: Make sure wires do not get pinched between the mounting strap and canopy or canopy and ceiling.

  21. Insert recommended bulbs (Not supplied).

  22. Carefully lower the glass shade[R] down over the bulb and socket[S], and seat the glass shade on the socket base[T]. Repeat for remaining glass shades.

CAUTIONS

CAUTION – RISK OF SHOCK

  • Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.

WARNING

  1. This fixture is intended for installation under the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.

CLEANING

  • Always be certain that the electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

© 2024 Kichler Lighting LLC. All rights reserved. For warranty information please visit: kichler.com/warranty

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KICHLER User Manuals

Related Manuals