Industrial IGS-6329 L3 Multi Port Gigabit Managed Ethernet Switch Installation Guide
- August 15, 2024
- INDUSTRIAL
Table of Contents
- Industrial IGS-6329 L3 Multi Port Gigabit Managed Ethernet Switch
- Product Information
- Product Usage Instructions
- Package Contents
- Requirements
- Wiring the Power Inputs
- Terminal Setup
- Recovering Back to Default Configuration
- Customer Support
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Industrial IGS-6329 L3 Multi Port Gigabit Managed Ethernet Switch
Product Information
Specifications
- Model: IGS-6329-8UP2S2X / IGS-6329-8UP2S4X
- Type: Industrial L3 Multi-Port Gigabit Managed Ethernet Switch
- Ports: 8 x 10/100/1000T PoE, 2 x 1G/2.5G SFP, 2 x 10G SFP+ (IGS-6329-8UP2S2X) / 4 x 10G SFP+ (IGS-6329-8UP2S4X)
Product Usage Instructions
Package Contents
Thank you for purchasing PLANET L3 Industrial Managed Switch, IGS-6329 DIN-
rail series. To get started, unpack the box and ensure it contains the
following items:
- The Industrial Managed Switch
- DB9 to RJ45 Interface RS232 Console Cable
- QR Code Sheet
- Wall Mounting Kit
- RJ45 Dust Cap
- SFP Dust Cap
Requirements
For management purposes, ensure you have the following equipment:
- Workstations running compatible operating systems with TCP/IP Protocols and Ethernet NIC
- Serial Port Connection with terminal emulator installed
- Ethernet Port Connection with network cables
- Web browsers like Google Chrome, Microsoft Edge, or Firefox
Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch contains a power socket and a
green terminal block connector. Follow these steps to insert the power wire:
- Identify the power socket on the Upper Panel.
- Use standard network (UTP) cables with RJ45 connectors to connect the power wire.
- Ensure a secure connection is made between the power wire and the green terminal block connector.
FAQ
-
Q: What should I do if any item is missing or damaged in the package?
A: If any item is missing or damaged, please contact your dealer immediately for assistance. -
Q: How can I access the Web interface of the Industrial Managed Switch?
A: Use a compatible web browser like Google Chrome, Microsoft Edge, or Firefox. If the interface is not accessible, try disabling anti-virus software or a firewall.
Package Contents
Thank you for purchasing PLANET L3 Industrial Managed Switch, IGS-6329 DIN- rail series. The descriptions of these models are as follows:
The descriptions of these models are shown below:
IGS-6329-8UP2S2X
| Industrial L3 8-Port 10/100/1000T 802.3bt PoE + 2-Port 1G/2.5G SFP + 2-Port
10G SFP+ Managed Ethernet Switch
---|---
IGS-6329-8UP2S4X
| Industrial L3 8-Port 10/100/1000T 802.3bt PoE + 2-Port 1G/2.5G SFP + 4-Port 10G SFP+ Managed Ethernet Switch
- “Industrial Managed Switch” mentioned in this Quick Installation Guide refers to the above models.
- Open the box of the Industrial Managed Switch and carefully unpack it. The box should contain the following items:
If any of these are missing or damaged, please contact your dealer immediately. If possible, retain the carton including the original packing materials to enable you to repack the product in case there is a need to return it to us for repair.
Requirements
The Industrial Managed Switch provides a local and remote login interface for management purposes. The following equipment is necessary for further management:
- Workstations running Windows 7/8/10/11, macOS 10.12 or later, Linux Kernel 2.6.18 or later, or other modern operating systems are compatible with TCP/IP Protocols.
- Workstations are installed with Ethernet NIC (Network Interface Card).
- Serial Port Connection (Terminal)
- The above Workstations come with a COM Port (DB9) or USB-to-RS232 converter.
- The above Workstations have been installed with terminal emulators, such as Hyper Terminal included in Windows XP/2003, putty, or tera term.
- Serial cable — one end is attached to the RS232 serial port, while the other end is to the console port of the Industrial Managed Switch.
- Ethernet Port Connection
- Network cables — Use standard network (UTP) cables with RJ45 connectors.
- The above PC is installed with a Web browser.
It is recommended to use Google Chrome, Microsoft Edge, or Firefox to access the Industrial Managed Switch. If the Web interface of the Indus-trial Managed Switch is not accessible, please turn off the anti-virus software or firewall and then try it again.
Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates a power socket and consists of one green terminal block connector within 6 contacts. Please follow the steps below to insert the power wire.
- Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2.
IGS-6329-Series: DC 48-54V
Dual power input is required for maximum PoE loading
- Single power input: Maximum 240-watt PoE budget
- Dual power input: Maximum 360-watt PoE budget
PWR1 and PWR2 must provide exactly the same DC voltage for power load balance while operating with dual power input.
Tighten the wire-clamp screws for preventing the wires from loosening.
- The wire gauge for the terminal block should be in the range of 12 to 24 AWG.
- Please check the wire AWG Ampere specification before connecting the PLANET Industrial Managed Switch.
Grounding the Device
Users MUST complete grounding wired with the device; otherwise, sudden
lightning could cause fatal damage to the device.
Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to the RJ45 type serial (console) port of the Industrial Managed Switch.
A terminal program is required to make the software connected to the Industrial Managed Switch.
- Run the terminal program on the OS.
- When the following screen appears, make sure that the COM port should be configured as:
- Baud: 115200
- Parity: None
- Data bits: 8
- Stop bits: 1
- Flow control: None
Logging on to the Console
Once the terminal has been connected to the device, power on the Industrial
Managed Switch, and the terminal will display “running testing procedures”.
- The following console screen is based on the IGS-6329-8UP2S4X. The display of the IGS-6329 series is the same as that of the IGS-6329-8UP2S4X.
- Then, the following message asks to log in with user username and password. The factory default user name and password are shown as follows as the login screen in Figure 4-1 appears.
The following console screen is based on the firmware version before April 2024.
- Username: admin
- Password: admin
The user can now enter commands to manage the Industrial Managed Switch. For a detailed description of the commands, please refer to the following chapters.
- For security reasons, please change and memorize the new password after this first setup.
- Only accept commands in lowercase letters under the console interface.
The following console screen is based on the firmware version of April of 2024 or after.
- User name: admin
- Password: sw + the last 6 characters of the MAC ID in lowercase
Find the MAC ID on your device label. The default password is “sw” or “mc” followed by the last six lowercase characters of the MAC ID.
Enter the default username and password, then set a new password according to the rule-based prompt and confirm it. Upon success, press any key to return to the login prompt. Log in with “admin” and the “new password” to access the CLI.
The user can now enter commands to manage the Industrial Managed Switch. For a detailed description of the commands, please refer to the following chapters.
Configuring IP Address via Console
The Industrial Managed Switch is shipped with default IP address shown below:
- IP Address: 192.168.0.100
- Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Switch, please use the procedure as follows:
Display of the Current IP Address
-
At the “#” prompt, enter “show ip interface brief”.
- IGS-6329-Series # shows ip interface brief
-
The screen displays the current IP address shown in Figure 4-4.
Configuration of the IP Address -
At the “#” prompt, enter the following command and press
as shown in Figure 4-5. - IGS-6329-Series# configure terminal
- IGS-6329-Series (config)# interface vlan 1
- IGS-6329-Series (config-if-vlan)# ip address 192.168.1.100 255.255.255.0
- The previous command would apply the following settings for the Industrial Managed Switch.
- IP Address: 192.168.1.100
- Subnet Mask: 255.255.255.0
-
Repeat step 1 to check if the IP address has changed.
Storing Current Switch Configuration
- At the “#” prompt, enter the following command and press
.
copy running-config startup-config
If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the Industrial Managed Switch through the new IP address.
Note
If you are not familiar with the console command or the related parameter,
enter “help” anytime in the console to get the help description.
-
Starting Web Management
The following shows how to start up the Web Management of the Industrial
Managed Switch. Note the Industrial Managed Switch is configured through an
Ethernet connection. Please make sure the manager PC must be set to the same IP -
subnet address.
For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Logging in to the Industrial Managed Switch
-
Use Chrome 98.0.xxx or above for the Web browser and enter IP address
https://192.168.0.100 (the factory-default IP address) to access the Web interface. -
When the following dialog box appears, please enter the default user name “admin” and password “admin” (or the password you have changed before) as shown in Figure 5-2.
- Default IP Address: 192.168.0.100
- Default Username: admin
- Default Password: admin
-
After entering the password, the main screen appears as shown in Figure 5-6.
- The following web screen is based on the firmware version of April of 2024 or after.
-
When the following dialog box appears, please enter the default user name “admin” and the password. Refer to Section 4.1 to determine your initial login password.
- Default IP Address: 192.168.0.100
- Default User Name: admin
- Default Password: sw + the last 6 characters of the MAC ID in lowercase
-
Find the MAC ID on your device label. The default password is “sw” or “mc” followed by the last six lowercase characters of the MAC ID.
-
After logging in, you will be prompted to change the initial password to a permanent one.
-
Enter the default username and password, then set a new password according to the rule-based prompt and confirm it. Upon success, press any key to return to the login prompt. Log in with “admin” and the “new password” to access the Web interface.
-
The Switch Menu on the top of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “Routing”, “QoS”, “Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.
Now, you can use the Web management interface to continue the Switch management. Please refer to the user manual for more.
If you are not familiar with Switch functions or the related parameters, press the “Help icon” anytime on the Web page to get the help description.
Saving Configuration via Web
To save all applied changes and set the current configuration as a startup
configuration, the startup-configuration file will be loaded automatically
across a system reboot.
- Click the Save icon on the top Switch Menu bar.
- Press the “Save Configuration” button.
- Or the other way to save the setting is to Click Maintenance and save Startup Config.
Recovering Back to Default Configuration
IP address has been changed or admin password has been forgotten – To reset the IP address to the default IP Address “192.168.0.100” and the user name password to factory default mode (default password is admin or sw + the last 6 characters of the MAC ID in lowercase), press the hardware-based reset button on the front panel for about 5~10 seconds. After the device is rebooted, you can log in to the management Web interface within the same subnet of 192.168.0.xx and the default password. Be noted that all the previous setups will disappear after the factory default reset is made.
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on the PLANET website first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
-
PLANET online FAQs:
https://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw. -
IGS-6329-DIN-rail Series User’s Manual:
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=IGS-6329&view=3#list.
(Please select your switch model name from the Product Model drop-down menu)
- Copyright © PLANET Technology Corp. 2024.
- Contents are subject to revision without prior notice.
- PLANET is a registered trademark of PLANET Technology Corp.
- All other trademarks belong to their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>