Einhell GE-DP 5220 LL ECO Submersible 2 in 1 Pump Instruction Manual
- August 14, 2024
- Einhell
Table of Contents
- Einhell GE-DP 5220 LL ECO Submersible 2 in 1 Pump
- Product Information
- Product Usage Instructions:
- Safety regulations
- Layout and items supplied
- Proper use
- Technical Data
- Before starting the equipment
- Operation
- Replacing the power cable
- Cleaning, maintenance, and ordering of spare parts
- Disposal and recycling
- Storage
- Troubleshooting guide
- Service Information
- Warranty certificate
- Declaration Of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Einhell GE-DP 5220 LL ECO Submersible 2 in 1 Pump
Product Information
The Dirty Water Pump is designed for pumping dirty water from various sources.
Specifications:
- Model: GE-DP 7330 LL ECO, GE-DP 5220 LL ECO
- Art.-Nr.: 41.707.90, 41.707.80
- I.-Nr.: 21031, 21030
Product Usage Instructions:
-
Safety Regulations:
Ensure to read all safety regulations and instructions provided in the manual to prevent electric shock, fire, or injuries. Keep safety regulations in a safe place for future reference. -
Layout and Items Supplied:
-
Layout:
* Universal hose connection
* Floating switch
* Screw for height adjustment
* Intake cage
* Handle
* Suspension eye
2. **Items Supplied:
** Check that all parts are included as per the scope of delivery. Contact the service center or sales outlet within 5 days of purchase if any parts are missing.
- Proper Use:
If using the pump in bodies of water with a muddy bottom, place it slightly elevated, for example, on bricks. Do not use the pump for continuous operation as a circulating pump in a pond to avoid shortening its lifespan.
FAQ:
-
Q: Can children use this equipment?
A: No, children are not allowed to use this equipment or perform maintenance tasks with it. Always supervise individuals with limited capacities or those with no experience when using the equipment. -
Q: What power source is recommended for the pump?
A: The pump must be powered via an earth-leakage circuit breaker (RCD) with a rated fault current of no more than 30 mA according to VDE standards.
Danger!
When using the equipment, a few safety pre-cautions must be observed to avoid
injuries and damage. Please read the complete operating instructions and
safety regulations with due care. Keep this manual in a safe place, so that
the in-formation is available at all times. If you give the equipment to any
other person, hand over these operating instructions and safety regulations as
well. We cannot accept any liability for damage or accidents which arise due
to a failure to follow these instructions and the safety instructions.
Explanation of the symbols used (see Fig. 10)
- Danger! – Read the operating instructions to reduce the risk of injury.
Safety regulations
Danger!
Read all safety regulations and instructions. Any errors made in following the
safety regula-tions and instructions may result in an electric shock, fire,
and/or serious injury. Keep all safety regulations and instructions in a safe
place for future use. Children are not allowed to use this equipment. Children
are not allowed to carry out cleaning or maintenance. This equipment can be
used by people with limited physical, sensory, or mental capacities or those
with no experience and knowledge if they are supervised or have received
instruction in how to use the equip-ment safely and understand the dangers
which result from such use. Children are not allowed to play with the
equipment.
Danger!
The pump must be powered via an earth-leakage circuit breaker (RCD) with a
rated fault current of no more than 30 mA (according to VDE 0100 Part 702 and
738).
The equipment is not designed for use in swimming pools and paddling pools of any kind or other bodies of water in which people or animals may be present during operation. It is prohibited to operate the equipment if a person or animal is in the danger area. Ask your electrician!
- Before you put the equipment into operation, arrange for a specialist to check that the earthing, protective multiple earthing, or residual-current operated circuit-breaker circuit complies with the safety regulations of the power supply company and works correctly.
- The electrical plug-in connec-tions must be protected from wet conditions.
- If there is a risk of flooding, place the plug-in connections in an area that is safe from flooding.
- Strictly avoid pumping aggressive liquids and abrasive substances.
- Protect the equipment from frost.
- Protect the equipment from dry running.
- Take suitable measures to keep the equipment out of the reach of children.
- There is a risk of the liquid becoming contaminated by escaping lubricant.
- The pump is not allowed to be left outdoors in cold weather.
Layout and items supplied
Layout (Fig. 1/2)
- Universal hose connection
- Floating switch
- Screw for height adjustment
- Intake cage
- Handle
- Suspension eye
Items supplied
Please check that the article is complete as specified in the scope of
delivery. If parts are missing, please contact our service center or the sales
outlet where you made your purchase at the latest within 5 working days after
purchasing the product and upon presentation of a valid bill of purchase.
Also, refer to the warranty table in the service information at the end of the
operating instructions.
- Open the packaging and take out the equip-ment with care.
- Remove the packaging material and any packaging and/or transportation braces (if available).
- Check to see if all items are supplied.
- Inspect the equipment and accessories for transport damage.
- If possible, please keep the packaging until the end of the guarantee period.
Danger!
The equipment and packaging material are not toys. Do not let children play
with plastic bags, foils, or small parts. There is a danger of swallowing or
suffocating!
- Dirty water pump
- Universal hose connection
- Original operating instructions
Proper use
- The equipment you have purchased is designed to pump water with a maximum temperature of 35 °C. This equipment must never be used for other liquids, especially not for engine fuels, cleaning agents, and other chemically-based products!
- Before you use the pump, clarify any possible special conditions that need to be fulfilled for the installation!
- For example, additional safety measures may be needed if property damage could result from a power failure, soiling, or a defective gasket. Examples of such safety measures:
- Pumps running in parallel on a separately protected power circuit, moisture sensors for switching off the pumps, and similar safety arrangements. Be sure to consult a professional plumber if you have any doubts.
- The equipment can be used wherever you want to move water, e.g. in the house, in the garden, and for many other applications. It must not be used to operate swimming pools!
- If you want to use the equipment in bodies of water with a natural, muddy bottom, place the equip-ment in a slightly elevated position, e.g. on bricks.
- The equipment is not designed for continuous operation, e.g. as a circulating pump in a pond. In this case, the equipment’s anticipated life will be greatly shortened because the equipment was not designed for continuous loading.
- The equipment is to be used only for its prescribed purpose. Any other use is deemed to be a case of misuse. The user/operator and not the manufacturer will be liable for any damage or injuries of any kind caused as a result of this.
- Please note that our equipment has not been designed for use in commercial, trade, or industrial applications. Our warranty will be voided if the machine is used in commercial, trade or industrial businesses or for equivalent purposes.
- The water may be contaminated by escaping lubricating oil/lubricant.
Technical Data
GE-DP 7330 LL ECO
- Mains connection ……………………. 230 V ~ 50 Hz
- Power consumption ……………………………. 730 W
- Max. pumping rate …………………………..16500 l/h
- Max. delivery head ………………………………. 8.5 m
- Max. immersion depth …………………………….. 7 m
- Max. water temperature ………………………… 35°C
- Hose connection: .. approx. 47.8 mm (G 1½ ) AG
- Max. size of foreign bodies: ……………….Ø 30 mm
- Switching point height: ON ….max. approx. 60 cm
- Switching point height: OFF …..min. approx. 5 cm
- Suction height: ………………………………min. 1 mm
- Protection ……………………………………………..IPX8
GE-DP 5220 LL ECO
- Mains connection ……………………. 230 V ~ 50 Hz
- Power consumption ……………………………. 520 W
- Max. pumping rate …………………………..13500 l/h
- Max. delivery head ………………………………. 7.5 m
- Max. immersion depth …………………………….. 7 m
- Max. water temperature ………………………… 35°C
- Hose connection: .. approx. 47.8 mm (G 1½ ) AG
- Max. size of foreign bodies: ……………….Ø 20 mm
- Switching point height: ON ….max. approx. 60 cm
- Switching point height: OFF …..min. approx. 5 cm
- Suction height: ………………………………min. 1 mm
- Protection ……………………………………………..IPX8
Before starting the equipment
Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data.
Installation
The equipment can be installed either:
- Stationary with a rigid pipeline or
- Stationary with a flexible hose line
The equipment must be fastened to the suspension eyelet with a rope (Fig. 2/Item 6). The maximum pumping rate is possible only with the largest possible line diameter; if smaller hoses or pipes are connected, the pumping rate will be reduced. If the universal hose connection (Fig. 1/Item 1) is used, it should be shortened (as shown in Fig. 9) to the connection used in order not to reduce the pumping rate unnecessarily. Flexible hoses must be fastened to the universal hose connection with a hose clip (not included in the scope of supply).
Note!
When installing, never hang the equipment by the discharge line or by the
power cable. The equipment must be hung up by the provided carry handle or
suspension eyelet, or it must rest on the bottom of the shaft. To ensure that
the equipment works properly, the bottom of the shaft always must be free of
sludge and other accumulations of dirt. If the water level is too low, the
sludge
in the shaft can quickly dry out and hinder the equipment from starting. It is
necessary therefore to check the equipment regularly (carry out trial start-
ups).
The pump shaft should measure at least 50 x 50 x 50 cm so that the floating switch can move freely.
Mains connection
Danger!
The equipment you have purchased comes with an earthing plug. The equipment is
designed for connection to a socket outlet with earthing contact for 230 V ~
50 Hz. Make sure that the socket outlet is sufficiently fused (at least 6 A)
and in good working order. Insert the power plug in the socket outlet and the
equipment is ready for operation.
Operation
You can put the equipment into operation after you have thoroughly read the installation and operating instructions. Pay attention to the following points:
- Make sure that the equipment is set up securely.
- Check that the discharge line is fitted correctly.
- Make sure that the electrical connection is 230 V ~ 50 Hz.
- Check that the electrical socket outlet is in good working order.
- Make sure that no moisture or water can ever reach the power connection.
- Make sure that the equipment does not run dry.
- To switch off the equipment, pull the power plug out of the socket outlet.
Setting the On/Off switching point:
The ON/OFF switching point can be infinitely adjusted with the height
adjustment facility. For this purpose, you must first slacken the screw (Fig.
3, Item 3). The switching differential can be infinicely adjusted by extending
or shortening the float cable (Fig. 3).
- The floating switch must be fitted so that the switching point height: ON and the switch point height: OFF can be reached easily and with little force. Check this by placing the equipment in a container filled with water and carefully raising and lowering the floating switch with your hand. You can then see whether the equipment switches on and off.
- Make sure that the distance between the floating switch head and the cable holder is not too small than 10 cm (Fig. 3). If the distance is too small, there is no guarantee that the equipment will work correctly.
- When adjusting the floating switch, make sure that the floating switch does not touch the bottom before the equipment is switched off. Important! Risk of dry running.
Manual operation:
Mount the floating switch as illustrated in Fig. 1. The equipment will then run
continuously. To prevent dry running, this operating mode is allowed only
under supervision. The equipment must be switched off (pull out the power plug)
as soon as no more water is emitted from the discharge line.
Dirty water mode (Fig. 4/5):
Turn the equipment counter-clockwise up as far as the stop (Fig. 4/5).
Shallow suction mode (Fig. 5):
- Turn the equipment clockwise down as far as the stop (Fig. 5).
- In shallow suction mode, water can be sucked up down to a level of 1 mm.
- Only clean water can be sucked up in shallow suction mode.
Please note:
For the equipment to suck up water in shallow suction mode there must be a
minimum depth of 10 mm of water.
Replacing the power cable
Danger!
If the power cable for this equip-ment is damaged, it must be replaced by the
manufacturer or its after-sales service or similarly trained personnel to
avoid damage.
Cleaning, maintenance, and ordering of spare parts
Danger!
Always pull out the mains power plug before starting any cleaning work.
Cleaning
- Keep all safety devices, air vents, and motor housing free of dirt and dust as far as possible. Wipe the equipment with a clean cloth or blow it with compressed air at low pressure.
- We recommend that you clean the device immediately each time you have finished using it.
- Clean the equipment regularly with a moist cloth and some soft soap. Do not use cleaning agents or solvents; these could attack the plastic parts of the equipment. Ensure that no water can seep into the device. The ingress of water into an electric tool increases the risk of an electric shock.
Cleaning the intake cage and pump housing (Fig. 5/6/7/8):
- Screw out the three screws (Fig. 6/Item B) counterclockwise.
- Turn the equipment up as far as the stop (Fig. 5). Note the position of the lug (Fig. 5/Item A) and remove the intake cage (Fig.7/Item 4).
- Clean the intake cage (Fig. 7/Item 4) and the pump impeller housing (Fig.7/Item C) with clean water.
- Assemble in reverse order.
- When assembled, the lug must be in the correct position (Fig. 8/Item A).
Maintenance
There are no parts inside the equipment that require additional maintenance.
Ordering replacement parts:
Please quote the following data when ordering replacement parts:
- Type of machine
- Article number of the machine
- Identification number of the machine
- Replacement part number of the part required
For our latest prices and information please go to www.Einhell- Service.com.
Disposal and recycling
The equipment is supplied in packaging to prevent it from being damaged in transit. The raw materials in this packaging can be reused or recycled. The equipment and its accessories are made of various types of material, such as metal and plastic. Never place defective equipment in your household refuse. The equipment should be taken to a suitable collection center for proper disposal. If you do not know the whereabouts of such a collection point, you should ask your local council offi ces.
Storage
Store the equipment and accessories in a dark and dry place at above-freezing temperature. The ideal storage temperature is between 5 and 30 °C. Store the electric tool in its original packaging.
Troubleshooting guide
Faults
| Cause|
Remedy
---|---|---
The equipment does not start| – Power supply not connected
– Floating switch does trigger
| – Check power supply
– Raise the position of the floating switch
The equipment does not pump| – Intake sieve clogged
– Discharge hose kinked
| – Clean intake sieve with a water jet
– Unkink the hose
The equipment does not cut out| – Floating switch cannot sink| – Place
equipment correctly on the shaft bottom
Insufficient pumping rate| – Intake sieve clogged
– Performance reduced due to heavily contaminated and abrasive water impurities
| – Clean intake sieve
– Clean equipment and replace worn parts
The equipment switches off after briefly running| – Motor circuit-breaker switches the equipment off due to excessive water contamination
– Water temperature too high; motor circuit-breaker switches the equipment off
| – Unplug the power plug and clean the equipment and shaft
– Ensure that the maximum permissible water temperature (35 °C) is not exceeded
For EU countries only
- Never place any electric power tools in your household refuse.
- To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and its implementation in national laws, old electric power tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
- As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment. The old equipment can be returned to a suitable collection point that will dispose of the equipment by the national recycling and waste disposal regulations. This does not apply to any accessories or aids without electrical components supplied with the old equipment.
- Please note that batteries and lamps (e.g. light bulbs) must be removed from the tool before it is dispo-sed of.
- The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of Einhell Germany AG.
- Subject to technical changes
Service Information
- We have competent service partners in all countries named on the guarantee certifi cate whose contact details can also be found on the guarantee certifi cate. These partners will help you with all service requests such as repairs, spare and wearing part orders, or the purchase of consumables.
- Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required for use as consumables.
Category | Example |
---|---|
Wear parts* | Impeller |
Consumables* | |
Missing parts |
Not necessarily included in the scope of delivery!
In the eff ect of defects or faults, please register the problem on the
internet at www.Einhell-Service.com. Please ensure that you provide a precise
description of the problem and answer the following questions in all cases:
- Did the equipment work at all or was it defective from the beginning?
- Did you notice anything (symptom or defect) before the failure?
- What malfunction does the equipment have in your opinion (main symptom)? Describe this malfunction.
Warranty certificate
Dear Customer,
All of our products undergo strict quality checks to ensure that they reach
you in perfect condition. In the unlikely event that your device develops a
fault, please contact our service department at the address shown on this
guarantee card. You can also contact us by telephone using the service number
shown. Please note the following terms under which guarantee claims can be
made:
-
These guarantee terms apply to consumers only, i.e. natural persons intending to use this product neither for their commercial activities nor for any other self-employed activities. These warranty terms regulate additional warranty services, which the manufacturer mentioned below promises to buyers of its new products in addition to their statutory rights of guarantee. Your statutory guarantee claims are not aff ected by this guarantee. Our guarantee is free of charge to you.
-
The warranty services cover only defects due to material or manufacturing faults on a product that you have bought from the manufacturer mentioned below and are limited to either the rectifi cation of said defects on the product or the replacement of the product, whichever we prefer.
Please note that our devices are not designed for use in commercial, trade, or professional applications. A guarantee contract will not be created if the device has been used by commercial, trade or industrial business or has been exposed to similar stresses during the guarantee period. -
The following are not covered by our guarantee:
-
Damage to the device caused by a failure to follow the assembly instructions or due to incorrect installation, a failure to follow the operating instructions (for example connecting it to an incorrect mains voltage or current type), or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care and maintenance.
-
Damage to the device caused by abuse or incorrect use (for example overloading the device or the use of unapproved tools or accessories), ingress of foreign bodies into the device (such as sand, stones or dust, transport damage), the use of force or damage caused by external forces (for example by dropping it).
-
Damage to the device or parts of the device caused by normal or natural wear or tear or by normal use of the device.
-
The guarantee is valid for 24 months starting from the purchase date of the device. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies if an on-site service is used.
-
To claim the guarantee, please register the defective device at: www.Einhell-Service.com. Please keep your bill of purchase or other proof of purchase for the new device. Devices that are returned without proof of purchase or a rating plate shall not be covered by the guarantee, because appropriate identifi cation will not be possible. If the defect is covered by our guarantee, then the item in question will either be repaired immediately and returned to you or we will send you a new replacement.
Of course, we are also happy off er a chargeable repair service for any defects that are not covered by the scope of this guarantee or for units that are no longer covered. To take advantage of this service, please send the device to our service address. Also refer to the restrictions of this warranty concerning wear parts, consumables, and missing parts as set out in the service information in these operating instructions.
Declaration Of Conformity
We declare conformity per the EU directive and standards for article
UK/CA Declaration of Conformity
We, Einhell UK Ltd
Champions Business Park, First Floor Unit 10, Arrowe Brook Rd, Upton, Wirral
CH49 0AB, United Kingdom declare the conformity to UK standards and
legislation was assessed for:
We declare conformity per the EU directive and standards for the article.
UK/CA Declaration of Conformity
We, Einhell UK Ltd
Champions Business Park, First Floor Unit 10, Arrowe Brook Rd, Upton, Wirral
CH49 0AB, United Kingdom declare the conformity to UK standards and
legislation was assessed for:
References
Read User Manual Online (PDF format)