REGENCY LRI4E Liberty Gas Insert Owner’s Manual

August 16, 2024
Regency

REGENCY LRI4E Liberty Gas Insert

Specifications

  • Models: LRI4E-NG11 Natural Gas, HRI4E-NG11 Natural Gas, LRI4E-LP11 Propane, HRI4E-LP11 Propane
  • Manufacturer: Regency
  • Approval: Approved by Intertek for safety and efficiency
  • Safety Feature: ProFlame 1 system fitted with On Demand Pilot

Safety Precautions

  • Do not store or use gasoline or other flammable vapors and liquids near the appliance.
  • If you smell gas, take the necessary precautions and contact a qualified installer or gas supplier.
  • Keep children away from the hot glass viewing area to prevent burns.
  • Ensure proper installation and regular maintenance by qualified personnel.

Operation Instructions

  1. Before operation, ensure the appliance is clean and free from obstructions.
  2. Follow the specific lighting instructions provided in the manual.
  3. In case of continuous inactivity for a full seven days, the On Demand Pilot safety feature will shut down the gas valve.
  4. Monitor the appliance while in operation and keep flammable items away.

FAQs

Q: What should I do if I smell gas?
A: If you detect a gas odor, immediately turn off the appliance, open windows for ventilation, and contact a qualified installer or gas supplier.

Q: How often should maintenance be performed?
A: Regular maintenance and cleaning should be performed at least once a year by a qualified technician to ensure safe and efficient operation.

WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

– WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance. · Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately. · Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s
instructions. · If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Tested by:

Certified to/Certifié pour: CSA 2.17-2017 ANSI Z21.88-2019 CSA 2.33-2019

Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.

919-933j

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4

01.16.24

TO THE NEW OWNER

Congratulations! You are the owner of a state-of-the-art Gas Insert by Regency.

The Regency Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The models LRI4E / HRI4E of this series have been approved by Intertek for both safety and efficiency as it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.

Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.

HOT GLASS WILL CAUSE BURNS
DO NOT TOUCH GLASS UNTIL COOLED
NEVER ALLOW CHILDREN TO TOUCH GLASS

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at risk individuals.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE, GASOLINE, AND ANY OTHER LIQUIDS WITH FLAMMABLE VAPOURS AWAY.

KEEP BURNER AND CONTROL COMPARTMENT CLEAN.

SEE INSTALLATION AND OPERATING INSTRUCTIONS ACCOMPANYING

APPLIANCE.

920-408

LA SURFAC PEUT CAUS
NE TOUCHE SURFACE V
NE LAISSEZ ENFANT TO VITRÉE.
L’écran pare-étincelles fourni avec ce foyer réduit le ris contact accidentel avec la vitre chaude et doit être inst enfants et des personnes à risque.
ATTENTION
Risque de brûlures graves. Ne pas toucher l’appareil lorsqu’il fonctionne. Ne pas laisser les enfants s’approcher de l’appare vêtements, les meubles et tout gaz ou liquide infla à distance de l’appareil. S’assurer que le brûleur et le compartiment des co Voir les instructions d’installation et d’utilisation q l’appareil.

920-408

4.34.7 Instruction Plate For a glass-fronted gas appliance where the temperature of the glass viewing area outside surface exceeds the limits specified in Clause 5.14.4, the following graphic danger and statements shall be shown on a Class IIIA-2 Permanent Label. 4.34.6 Instruction Plate
Liberty EGacahsappliance shHallobreizaroanCGlaasssIIIB markiHngowriiztholnettHersRoIn4Ea contrastinLgibbaecrktgyroLuRndI,4loEcated Inserts Beadnjaecfeitnst to the cIonnstreorlltinsgBdeevniceefiotrsin an equally conspicuous position where the instruction can be easily read.

April 22/14: Created draft

Double sided

Material: Synthetic Paper

ON

DEMAND PILOT Size 5.965″ W x 5.71″ H Color: As shown in artwork

LIGHT

(SEVEN

DAY

SAFETY

TIMER)

Important information if using the appliance in CPI (continuous pilot mode) only.
This appliance is a ProFlame 1 system fitted with the “On Demand” Pilot, a safety feature which will shut down the gas valve completely by extinguishing the pilot light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the “on” position. Each time the main burner shuts down, manually or through the call from the thermostat, the seven day timer starts again. The seven day inactivity timer is controlled within the circuit board. Therefore, if in CPI mode and when the pilot light is extinguished after seven straight days of inactivity, the IPI/CPI rocker switch will remain in the “on” position. Therefore, all that is required to relight the pilot would be to press the on/off button on the remote control transmitter from “on” to “off” and back to “on”. Once the pilot has re-established operation will resume as normal. There is no requirement to do anything with the IPI/CPI rocker switch. If the unit never goes as long as seven full days without a call for heat, the pilot will remain lit until it is manually shut-off. If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven day timer will apply. See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or re-light the pilot.

15 16

28

25

8 | LRI4E / HRI4E-11 Direct Vent Gas Insert

20″ 507

safety decal

COPY OF SAFETY LABEL
This is a copy of the labels that accompany each LRI4E Gas Insert. We have printed a copy of the contents here for your review.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Duplicate Serial number/Copie No de série

481

Model/Modèle: LRI4E-NG11

Model/Modèle: LRI4E- LP11

Listed/Nom: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ VENTILÉ DO NOT REMOVE THIS LABEL /

Certified to / Certifié : ANSI Z21.88:2019 · CSA-2.33:2019

NE PAS ENLEVER CETTE ÉTIQUETTE

CSA 2.17-2017 MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.

481

C# 4001172

Refer to Intertek’s Directory of Building Products for detailed information. Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.

Serial No. / No de série

NATURAL GAS FIREPLACE INSERT: MODEL LRI4E-NG11

MODÈLE LRI4E-NG11

Factory Equipped For Altitude 0-4500ft. (0-1370m)

FONCTIONNANT AU GAZ NATUREL

Min. supply pressure

5″

Low Setting Man. pressure

1.6″

Max. Manifold pressure

3.5″

WC (1.25 kpa) WC (0.41 kpa) WC (0.87 kpa)

Pression d’alimentation minimale Pression de sortie (manifold) – basse Pression de sortie (manifold) – max.

Orifice size

37

DMS

Taille de l’orifice

Minimum input

22,000 Btu/h (6.45 kW)

Débit calorifique minimal

Maximum input

31,000 Btu/h (9.09 kW)

Débit calorifique maximal

PROPANE GAS FIREPLACE INSERT: MODEL LRI4E-LP11

Factory Equipped For Altitude 0-4500ft. (0-1370m)

Min. supply pressure

11″

WC (2.73 kpa)

Low Setting Man. pressure

6.4″

WC (1.59 kpa)

Max. Manifold pressure

10″

WC (2.48 kpa)

Orifice size

53

DMS

Minimum input

26,000 Btu/h (7.62 kW)

Maximum input

31,000 Btu/h (9.09 kW)

MODÈLE LRI4E-LP11 FONCTIONNANT AU GAZ PROPANE
Pression d’alimentation minimale Pression de sortie (manifold) – basse Pression de sortie (manifold) – max. Taille de l’orifice Débit calorifique minimal Débit calorifique maximal

Minimum Clearances to Combustibles from Insert/Dégagements min. combustibles

Side wall / mur latéral A 8″

(203mm)

Ceiling / Plafond

B 60″

(1524mm)

Mantel / Manteau

C 35″

(889mm)

Min. Alcove Width/

Largeur min. alcôve

K 54″

(1372mm)

B

Max. Alcove Depth/

Prof. max. alcôve

L 36″

(914mm)

G C

A L

Mantel Clearances / Dégagements manteau

Min. Hearth Width /

Largeur min. âtre

D 14″

(356mm)

Min. Hearth Length/

Longueur min. âtre E 40″ (1016mm)

Max. Mantle Depth/

Prof. max. manteau G 12″

(305mm)

MADE IN CANADA /FABRIQUÉ AU CANADA

D

E

K

FPI Fireplace Products International Ltd., Delta BC, CANADA

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and

Propane Installation Code, CSA B149.1.

This appliance is only for use with the type of gas indicated on the rating plate.

This appliance is not convertible for use with other gases unless a certified kit is used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured

(mobile) home where not prohibited by local codes. See owner’s manual for details.

WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original

parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.

Rev B – Corrected FPI name

For tAhuegS. 3ta/2te2:of MassachRuseevtCts,- tShteanadpaprdlisan&cwesoridnidnig- updated

vidual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA
720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

Remove faceplate from front of unit (see manual) Once the faceplate is removed the rating plate will be located below the glass (see picture).
DO NOT REMOVE THE DECAL FROM THE UNIT

LRI4E / HRI4E-11 Direct Vent Gas Insert | 9

safety decal
COPY OF SAFETY LABEL
This is a copy of the labels that accompany each HRI4E Gas Insert. We have printed a copy of the contents here for your review.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Duplicate Serial number

486

Model/Modèle: HRI4E-NG11

Model/Modèle: HRI4E- LP11

Listed/Nom: VENTED GAS FIREPLACE HEATER / FOYER AU GAZ VENTILÉ DO NOT REMOVE THIS LABEL /

Certified to / Certifié : ANSI Z21.88:2019 · CSA-2.33:2019

NE PAS ENLEVER CETTE ÉTIQUETTE

C#4001172

CSA 2.17-2017
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. Refer to Intertek’s Directory of Building Products for detailed information. Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.

486
Serial No. / No de série

NATURAL GAS FIREPLACE INSERT: MODEL HRI4E-NG11

Factory Equipped For Altitude 0-4500ft. (0-1370m)

Min. supply pressure

5″

WC (1.25 kpa)

Low Setting Man. pressure

1.6″

WC (0.41 kpa)

Max. Manifold pressure

3.5″

WC (0.87 kpa)

Orifice size

37

DMS

Minimum input

22,000 Btu/h (6.45 kW)

Maximum input

31,000 Btu/h (9.09 kW)

MODÈLE HRI4E- NG11 FONCTIONNANT AU GAZ NATUREL Pression d’alimentation minimale Pression de sortie (manifold) – basse Pression de sortie (manifold) – max. Taille de l’orifice Débit calorifique minimal Débit calorifique maximal

PROPANE GAS FIREPLACE INSERT: MODEL HRI4E-LP11

Factory Equipped For Altitude 0-4500ft. (0-1370m)

Min. supply pressure

11″

WC (2.73 kpa)

Low Setting Man. pressure

6.4″

WC (1.59 kpa)

Max. Manifold pressure

10″

WC (2.48 kpa)

Orifice size

53

DMS

Minimum input

26,000 Btu/h (7.62 kW)

Maximum input

31,000 Btu/h (9.09 kW)

MODÈLE HRI4E- LP11 FONCTIONNANT AU GAZ PROPANE
Pression d’alimentation minimale Pression de sortie (manifold) – basse Pression de sortie (manifold) – max. Taille de l’orifice Débit calorifique minimal Débit calorifique maximal

Minimum Clearances to Combustibles from Insert

Side wall Ceiling Mantel Min. Alcove Width Max. Alcove Depth

A 8″ B 60″ C 35″ K 54″ L 36″

(203mm) (1524mm) (889mm) (1372mm) (914mm)

Mantel Clearances/Dégagements manteau Min. Hearth Width D 14″ (356mm) Min. Hearth Length E 40″ (1016mm) Max. Mantle Depth G 12″ (305mm) .
MADE IN CANADA /FABRIQUÉ AU CANADA
FPI Fireplace Products International Ltd., Delta BC, CANADA

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals