LogTag UTRED30-16 Vaccine Data Logger User Guide
- August 12, 2024
- LogTag
Table of Contents
- LogTag UTRED30-16 Vaccine Data Logger
- Product Information
- Product Usage Instructions
- What’s Included
- Battery Installation
- Downloading LogTag Analyzer
- Configuring your UTRED30-16
- Starting your UTRED30-16
- Downloading Results
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LogTag UTRED30-16 Vaccine Data Logger
Product Information
Specifications
- Model: UTRED30-16
- Power Source: 2x AAA batteries (main), USB cable (backup)
- External Probe: ST100X (not included)
- USB Cable and AC Adapter included
Product Usage Instructions
Battery Installation
The AAA batteries are the main power source for your UTRED30-16.
- Use a small phillips screwdriver to remove the cover on the back of the device.
- Install the 2x AAA batteries, following the correct polarity.
- Securely close the battery cover.
Downloading LogTag Analyzer
To download LogTag Analyzer:
- Visit https://www.logtag-recorders.com/en/support/
- Click ‘Go To Downloads Page’ and then ‘Download Now’.
- Run or save the file and follow the Setup Wizard instructions to install Analyzer.
Configuring your UTRED30-16
To configure your device:
- Connect UTRED30-16 to your computer using the USB cable.
- Open LogTag Analyzer and select ‘Configure’ or use the ‘Wizard’ icon.
- Select channels to log, adjust configuration settings, and upload them to the logger.
Starting your UTRED30-16
Before starting recording:
- Connect external probe(s) to the correct sensor port(s).
- Press and hold the START/Clear/Stop button until ‘STARTING’ appears.
- Release the button when ‘READY’ disappears to start recording temperature data.
Frequently Asked Questions (FAQ)
-
Q: What should I do if my UTRED30-16 does not start?
A: Ensure AAA batteries are not low and there is no USB power issue. Check the battery installation and connections with external probes. -
Q: Can I use the USB cable as the primary power source?
A: The USB cable can be used as a backup power source; however, it is recommended to use AAA batteries as the main power source. -
Q: Do I need to use the Glycol Buffer with UTRED30-16?
A: The Glycol Buffer is optional and not included. It is used for calibration purposes in specific applications.
What’s Included
Please check you have each of the items shown below before continuing with setting up your UTRED30-16.
Battery Installation
The AAA batteries are the main power source for your UTRED30-16.
A USB cable is another power backup source if you wish to power the unit
permanently via the USB socket.
- You will need a small phillips (cross-shaped) screwdriver to remove the cover on the back of the UTRED30-16 case.
- Once you have removed the battery cover, install the 2x AAA batteries. Take note of the direction each battery must be installed.
- Once both batteries are securely installed, replace the battery cover and secure via the screw you used to open the cover.
Warning: Please note the UTRED30-16 will not start if AAA batteries are low and there is no USB power.
Downloading LogTag Analyzer
To download the latest LogTag Analyzer, open your browser and navigate to: https://www.logtag-recorders.com/en/support/
- Click ‘Go To Downloads Page’ button
- Click ‘Download Now’ to start the download
- Click ‘Run’ or ‘Save File’ then double-click the downloaded file to open Analyzer Setup Wizard
- Once the Analyzer Setup Wizard is open, follow the on-screen prompts to install Analyzer onto your computer
- Click ‘Finish’ to exit the Setup Wizard
Warning: Please ensure no other LogTag software is currently running on your computer before running the Analyzer software.
Configuring your UTRED30-16
Connect your UTRED30-16 to your computer via the USB cable provided. The USB socket on the device is located on the bottom, protected by a rubber seal.
- Open LogTag Analyzer
- Click ‘Configure’ from the ‘LogTag’ menu or click the ‘Wizard’ icon. Please select which Channel(s) you wish to log, in ‘Log channels:’ setting.
- Adjust your logger configuration settings as required. For more information on configuration settings, please refer to Configuring the UTRED30-16 in the Product User Guide or press ‘F1’ for help from your keyboard
- Click ‘Next’ to upload the configuration settings to the logger
- Click ‘Close’ to exit the configuration page
Note: Please ensure you have LogTag Analyzer version 3.1.15 onwards for configuration of the UTRED30-16 dual-sensor models.
Starting your UTRED30-16
Before starting, please ensure you have connected the ST100X external probe(s)
into the correct Channel sensor port(s) you have configured to record from.
Press and hold the START/Clear/Stop button. STARTING will appear along with
READY. Release the button once READY disappears.
The UTRED30-16 now records temperature data.
The Logger will not start if:
- You release the button before READY disappears.
- You keep holding the button for more than 2 seconds after READY disappears.
- The backup battery is critically low and the logger is not connected to power.
Press the CHANNEL button to change the channel on screen. In this example, the display switched from CH1 to CH2.
Note: The sensor cover can be inserted in an unused sensor port.
During Recording
To view more information about clearing alarms and resetting and reviewing
trip statistics, please refer to the Product User Guide.
Downloading Results
Connect your UTRED30-16 to your computer via the USB cable provided. The USB socket on the device is located on the bottom, protected by a rubber seal.
A new device drive will appear in file explorer with the files containing the
recorded data for the Channel(s) monitored.
Alternatively, you can follow the steps below:
- Open LogTag Analyzer
- Click ‘LogTag’ from the ‘Download’ menu or press ‘F4’
- Click ‘Close’ to exit the download page
By default, auto-download is enabled in LogTag Analyzer so when you open the program, data results will be displayed after connecting your UTRED30-16 to your computer.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>