nordlux ALEC IP44 Moodmaker Fixed White LED Downlight Kit Instruction Manual

August 9, 2024
nordlux

nordlux ALEC IP44 Moodmaker Fixed White LED Downlight Kit

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-
PRODUCT

Product Information

Specifications:

  • Operating Voltage: 100-240V
  • IP Rating: IP20, IP44
  • Dimensions: 79-83mm x 73-79mm
  • Maximum Inter-connected Units: 15pcs

Product Usage Instructions

Installation:

  1. Before installation, ensure the power is switched off.
  2. Contact a local electrician for bathroom installations or for countries with specific safety requirements.
  3. Follow the provided guidelines for mounting and wiring the light fixture securely.

Adjusting Brightness/Memory Function:

  • Switch between brightness levels by toggling the switch in short intervals (<4 seconds).
  • To memorize a specific brightness level, maintain it for over 6 seconds and wait more than 6 seconds between switches.

Switch Positions:

  1. 100% Center – Switch once for maximum brightness.
  2. 50% Center – Switch twice for medium brightness.
  3. Ring – Switch thrice for night/ambiance light mode.
  4. All Off – Switch off all lights.

Cleaning and Maintenance:

  • Regularly clean the light fixture with a soft, dry cloth.
  • Ensure the power is off before performing any maintenance tasks.

FAQ

Common Questions:

What do the different IP ratings mean?
The IP20 rating indicates protection against solid objects larger than 50mm and no protection against water. The IP44 rating provides protection against solid objects larger than 1mm and water splashes from all directions.

How many light fixtures can be interconnected?
You can interconnect a maximum of 15 light fixtures.

How to reset the memory function?
To reset the memory function, switch off all lights, wait for 6 seconds, then toggle the switch on/off five times.

INSTRUCTION

STEP 1

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(1\)

STEP 2

STEP 3

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(3\)

STEP 4

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(4\)

STEP 5

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(5\)

STEP 6

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(6\)

DIMENSION

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(7\)

If you want to install this light fixture in your bathroom and knowing some countries have extra local installation/safety requirements, always contact your local electrician before installation (eg. France) !

Adjusting Brightness/Memory function

You switch easily from one to the other functionality (100%-50%-night/ambiance light) by switching short and less than 4 seconds between each step. If you lit your preferred position for longer than 6 seconds and also wait more than 6 seconds between 2 switches, your last position will be memorized what means by next short switch, the memorized position will be lit.

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(10\)

Reset function

If you use more than 1 spot in the same room and you want to synchronize the spot or you notice that the downlighters are desynchronized, you have to RESET the different downlighters. How you do? You switch off all spots and you wait for at least 6 seconds,than you switch on and off 5 times fast, let’s say all 5 switches in less than 5 seconds. After the 5 times on/off you switch on again. In that way all spots must be now in the position of 100% in the inner circle, synchronized again. If not, please repeat again.

nordlux-ALEC-IP44-Moodmaker-Fixed-White-LED-Downlight-Kit-FIG-
\(11\)

SYMBOLS

Protected against solid objects with a diameter of 1.0 mm or more. Protected against contact with dangerous parts with wires, etc.

IPX4: Raindrops falling from any angle will not affect the function/safety of the lamp.

The mounting instruction must not be discarded.

IMPORTANT!
Always shut off power to the circuit before starting installation work. In some countries electrical installation work may only be carried out by a authorized electrical contractor. Contact your local electricity authority for advice.The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

Disposal of waste equipment by users in private households in the European Union. This symbol indicates that this product must not be disposed of with your other household waste. Electrical and electronic equipment contain substances which may cause damage to human health and environment if not recycled correctly. It is your responsibility to hand over to a designated collection point for recycling of waste electrical and electronic equipment. When handing over for correct recycling you help to prevent these products straining nature and environment unnecessarily and to protect human health. For more information regarding correct disposal, please contact your local city office, your household waste disposal service or the store where you purchased this product.

Luminaires not suitable for covering with thermally insulation material.

The lamp is only suitable for connecting directly to the mains.

Class II: The lamp is double-insulated and does not need to be connected to the yellow/green earth wire.

For indoor use only.

We recommend the use of a 90° C temperature-resistant cable.

Mounting instruction

www.nordlux.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals