ADAMS HP-225BPS Rugged Cast Iron Instruction Manual

August 10, 2024
ADAMS

HP-225BPS Rugged Cast Iron

“`html

Specifications:

  • Model: ADAMS HP-225BPS

  • Burner Types: HU UPSHOT, HA INSHOT, SPT
    ECONOMY, G-2 POWER GAS

  • Gas Types: Natural Gas, Propane Gas

  • BTU/Hr. Input Range: Varies based on
    model

  • Gas Pipe Connection: 1/2″ or 3/4″ depending on
    model

  • Shipping Weight: Varies based on model

Product Usage Instructions:

HU UPSHOT AND HA INSHOT BURNERS:

The HU UPSHOT and HA INSHOT burners are designed for use in
various enclosures. They come completely factory wired with motor,
transformer, and terminal block mounting on a slide-out chassis.
The burners feature easily accessible air and firing rate
adjustment. Follow the specific installation instructions provided
for your model to ensure proper setup.

SPT ECONOMY UPSHOT BURNER:

The SPT ECONOMY UPSHOT burner is ideal for smaller enclosures.
It is equipped with a unique eductor-venturi concept for efficient
performance. Ensure that the gas valve and manifold are properly
installed and that the pilot system is functioning correctly before
use.

G-2 POWER GAS BURNER:

The G-2 POWER GAS burner offers high static pressure
capabilities for consistent firing even under adverse conditions.
It features direct spark ignition and allows for external orifice
changes without disassembling the burner. Choose the appropriate
stainless steel flame retention head based on your input range
needs.

Frequently Asked Questions (FAQ):

Q: How do I determine the correct burner type for my

application?

A: Refer to the specifications provided in the manual to match
the burner type with your enclosure size and heating
requirements.

Q: Can I use natural gas and propane interchangeably with these

burners?

A: Some models support both natural gas and propane, but always
check the specific model’s compatibility and make necessary
adjustments before switching between gas types.

Q: What should I do if the burner fails to ignite?

A: Check the gas supply, pilot system, and ignition components
for any issues. Ensure proper ventilation and follow the
troubleshooting steps outlined in the manual.

“`

This Owner’s Manual is provided and hosted by Appliance Factory Parts.
ADAMS HP-225BPS Owner’s Manual
Shop genuine replacement parts for ADAMS HP-225BPS
Find Your ADAMS HVAC Parts – Select From 98 Models ——– Manual continues below ——–

®

HU UPSHOT AND HA INSHOT BURNERS
Rugged cast iron adjustable venturi ­ places the flame in optimum location for oil furnaces. Readily removable pilot, flame spreader and pilot lighter. Durable pre-drilled steel mounting flange ­ for easy mounting. Optional adjustable orifice available. Gas Saver model available ­ pilot light is on only during heating cycle. Optional collar flange reduces tube length.
SPT ECONOMY UPSHOT BURNER
Adjustable venturi length and height ­ places flame in optimum location for virtually all coal furnaces or boilers. Rugged cast iron flame spreader. Extremely compact design ­ fits where other burners will not. Trim plate mounting for ease of installation. Optional adjustable orifice, extra length riser available. Gas Saver model available ­ pilot light is on only during heating cycle.
HP­SPACESAVER POWER BURNER
COMPACT DESIGN ­ SAVES SPACE ­ ADJUSTABLE ORIFICE
Fits the smallest enclosures. Easily accessible air and firing rate adjustment. Completely factory wired with motor, transformer, and terminal block mounting on slide out chassis. Slide out gas valve and manifold. Rugged steel mounting flange, 5″ or 8″ extension sleeve optional. Constant or intermittent pilot.
G-2­POWER GAS BURNER
A revoluntionary partial pre-mix system uses Adams unique eductor-venturi concept. High static pressure capabilities assure firing even under adverse conditions. For dependable direct spark ignition, the burner uses a separate high voltage transformer. A special designed manifold permits external orfice changes without the need of disassembling the burner. Six different stainless steel flame retention heads available to cover most input ranges.

HU UPSHOT
HA INSHOT
SPT ECONOMY
HP­SPACESAVER
G-2 POWER GAS BURNER

GAS BURNERS

Dimensions HU Left Side

Model HU-300 HU-250LP HU-300PS

BTU/Hr. Input

Gas Pipe

Maximum

Minimum Connection

290,000

NATURAL GAS

50,000

3/4″

250,000

PROPANE GAS

50,000

3/4″

GAS SAVER ­ NATURAL GAS

290,000

50,000

1/2″

Approximate Shipping Wt.
16 lbs.
16 lbs.
18 lbs.

HA Left Side

Model HA-300 HA-300PS

BTU/Hr. Input

Gas Pipe

Maximum

Minimum Connection

290,000

NATURAL GAS

50,000

3/4″

GAS SAVER ­ NATURAL GAS

290,000

50,000

1/2″

Approximate Shipping Wt.
16 lbs.
18 lbs.

SPT Left Side

Model SPT-300 SPT-350
SPT-400LP
SPT-300PS

BTU/Hr. Input

Gas Pipe

Maximum

Minimum Connection

290,000 350,000

NATURAL GAS

50,000

3/4″

50,000

3/4″

400,000

PROPANE GAS

50,000

3/4″

GAS SAVER ­ NATURAL GAS

290,000

50,000

1/2″

Approximate Shipping Wt.
18 lbs. 19 lbs.
18 lbs.
20 lbs.

63/4″ (73/4″)*

61/2″ (8″)*

8″

HP-225

(HP-400)

Right Side

*Dimensions represent HP400

Top housing width 83/4 (101/4)*

Model

BTU/Hr. Input

Gas Pipe

Maximum

Minimum Connection

HP-225 HP-225BPS HP-400 HP-400BPS

225,000 225,000 400,000 400,000

NATURAL GAS

50,000

3/4″

50,000

1/2″

100,000

3/4″

100,000

3/4″

LIQUEFIED PETROLEUM GAS

HP-225LP 225,000

50,000

3/4″

HP-225LPPS 225,000

50,000

1/2″

HP-400LP 400,000

100,000

3/4″

HP-400LPPS 400,000

100,000

1/2″

Approximate Shipping Wt.
26 lbs. 26 lbs. 31 lbs. 31 lbs.
26 lbs. 26 lbs. 30 lbs. 31 lbs.

G-2

1″

BTU/Hr. Input

Gas Pipe

Approximate

16″

Model

Maximum

Minimum Connection Shipping Wt.

8″

NATURAL OR PROPANE GAS

G-2T

240,000

50,000

1/2″

8″ G-2SD

255,000

70,000

1/2″

35 lbs. 34 lbs.

61/2″

71/2″

51/2″

8″

to 11″

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals