ideal HEATING Logicplus SYSTEM2 S Series Boilers User Guide
- August 8, 2024
- ideal HEATING
Table of Contents
- ideal HEATING Logicplus SYSTEM2 S Series Boilers
- Product Information
- Product Usage Instructions
- FAQ
- WEEE DIRECTIVE 2012/19/EU
- INTRODUCTION
- BOILER OPERATION
- SYSTEM WATER PRESSURE
- POINTS FOR THE BOILER USER
- CONDENSATE DRAIN
- GENERAL INFORMATION
- TROUBLESHOOTING
- DISPLAY FUNCTIONS – NORMAL OPERATION MODE
- DISPLAY FUNCTIONS – FAULT MESSAGES
- ABOUT COMPANY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ideal HEATING Logicplus SYSTEM2 S Series Boilers
Product Information
Specifications
- Model: Logic+ System2
- Variants: S15, S18, S24, S30
- Features: Full sequence automatic spark ignition, fan-assisted combustion
- Function: Provides central heating and hot water with a separate hot water cylinder
- Power Supply: 230 V ~ 50 Hz, 3A
Product Usage Instructions
Introduction
The Logic+ System2 is a system boiler designed for central heating and hot
water when used with a separate hot water cylinder. It features automatic
spark ignition and fan-assisted combustion.
Safety
Installation and any work on the appliance must be done by a Gas Safe
Registered engineer in compliance with Gas Safety Regulations. Follow the
instructions in the manual for safe and efficient operation.
Electricity Supply
Ensure the appliance is earthed and connected to a 230 V ~ 50 Hz power
supply with a 3A fuse.
System Water Pressure
Maintain the recommended system water pressure as specified in the manual
to ensure proper operation of the boiler.
Condensate Drainage
Monitor and ensure proper drainage of condensate produced during operation
through the waste pipe at the base of the boiler. A condensate plume may be
visible at the flue terminal.
FAQ
-
Where can I find spare parts for the Logic+ System2?
Use only spare parts authorized by Ideal Heating. You can find spare parts conforming to safety and performance specifications on Ideal Heating’s website or through authorized dealers. -
How do I troubleshoot common issues with the boiler?
Refer to the Troubleshooting section in the manual for guidance on identifying and resolving common issues. If problems persist, contact a qualified technician.
WEEE DIRECTIVE 2012/19/EU
Waste Electrical and Electronic Equipment Directive
- At the end of the product life, dispose of the packaging and product in a corresponding recycle centre.
- Do not dispose of the unit with the usual domestic refuse.
- Do not burn the product.
- Remove the batteries.
- Dispose of the batteries according to the local statutory requirements and not with the usual domestic refuse.
INTRODUCTION
- The Logic + System2 is a system boiler, featuring full sequence automatic spark ignition and fan assisted combustion. It is designed to provide central heating and hot water when a separate hot water cylinder is installed.
- Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler.
- A condensate ‘plume’ will also be visible at the flue terminal.
Safety
- Current Gas Safety (Installation & Use) Regulations or rules in force.
- It is the law that this appliance installation and any work carried out on the appliance is carried out by a Gas
- Safe Registered engineer in accordance with the above Regulations.
- It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler.
Electricity Supply
This appliance must be earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
IMPORTANT NOTES
- This appliance must not be operated without the casing correctly fitted and forming an adequate seal.
- If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes.
- If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer.
- Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with.
- This appliance can be used by children 8 years and above. Also persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, provided they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
CARBON MONOXIDE ALARMS
- Carbon monoxide detectors are installed near to the boiler to detect a gas leak. If a leak is detected the alarm will make a very loud noise. If you suspect that there is a fault with the alarm, you should first change the batteries.
- If you change the batteries and the fault does not clear, you must speak to your landlord or replace the device with another that complies to BS EN 50291-1:2010.
BOILER OPERATION
- A. Hot Keys
- B. Central Heating Temperature Knob
- C. Boiler Status Display
- D. Burner On indicator
TO START THE BOILER
-
Start the boiler as follows:
- Switch on electricity to the boiler and check that all external controls, e.g. programmer, room thermostat and cylinder thermostat are on.
- If a Boiler symbol is shown on the screen then press Mode until Ready or On is shown underneath the Boiler symbol. If Tap and Radiator symbols are shown press Mode until Ready or On is shown underneath the radiator symbol..
- If a Boiler symbol is shown on the screen turn the temperature control knob until 80°C is shown. If Tap and Radiator symbols are shown turn the temperature control knob until 30°C is shown..
-
Once the boiler has lit see the following page about where the Temperature Control knob should be set.
Note. In normal operation the boiler status display (D) will display messages. -
Boiler frost protection – boiler will fire if temperature is below 5ºC.
-
During normal operation the burner on symbol (C) will remain illuminated when the burner is lit.
-
If the boiler fails to light after five attempts the following fault messages will be displayed:
-
To restart the boiler, press Restart. The boiler will repeat the ignition sequence. If the boiler still fails to light consult a Registered Gas Installer.
OPERATION MODES
Winter Conditions
(Central Heating and Domestic Hot Water required)
- If a Boiler symbol is shown on the display then press Mode until either Ready or On is shown under the Boiler symbol. If Tap & Radiators symbols are shown then press Mode until Ready or On is shown under the radiator and tap symbol. .
- The boiler will fire and supply heat to the radiators.
Summer Conditions
(Domestic Hot Water only required)
If a Boiler symbol is shown on the display then central heating must be
disabled at the timer or room thermostat. If Tap and Radiators symbols are
shown on the display then press Mode until Ready or On is shown under the Tap
and Off is shown under the Radiator. .
Boiler Off
If a Boiler symbol is shown on the display then press Mode until Off is shown
under the Boiler symbol. If Tap and Radiator symbols are shown on the display
then press Mode until Off is shown underneath the Radiator symbol.
CONTROL OF WATER TEMPERATURE
Central Heating
The boiler controls the central heating radiator temperature to a maximum of
80oC, adjustable via the central heating temperature knob (B).
Approximate temperatures for central heating:
Knob Setting| Central Heating Radiator Temperature
(approx.)
---|---
Minimum| 30ºC
Maximum| 80ºC
For economy setting refer to Efficient Heating System Operation.
EFFICIENT HEATING SYSTEM OPERATION
- The boiler is a high efficiency, condensing appliance which will automatically adjust its output to match the demand for heat.
- Therefore gas consumption is reduced as the heat demand is reduced.
- The boiler condenses water from the flue gases when operating most efficiently. To operate your boiler efficiently (using less gas) turn the temperature control knob (B) until the leaf symbol is shown . In winter periods it may be necessary to turn the knob towards the ‘MAX’ position to meet heating requirements. This will depend on the house and radiators used.
- Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10%.
WEATHER COMPENSATION
When the Weather Compensation option is fitted to the system then the central
heating temperature knob (B) becomes a method of controlling room temperature.
Turn the knob clockwise to increase room temperature and anti-clockwise to
decrease room temperature. Once the desired setting has been achieved, leave
the knob in this position and the system will automatically achieve the
desired room temperature for all outside weather conditions.
BOILER FROST PROTECTION
- The boiler is fitted with frost protection that operates in all modes, provided the power supply to the boiler is always turned on. If the water in the boiler falls below 5ºC, the frost protection will activate and run the boiler to avoid freezing.
- The process does not guarantee that all other parts of the system will be protected.
- If a system frost thermostat has been installed, the boiler must be set in winter mode, with Ready or On [Ready or On ] shown under either the Boiler or Radiator symbol, for the system frost protection to run.
- If no system frost protection is provided and frost is likely during a short absence from home it is recommended to leave the system heating controls or built in programmer (if fitted) switched on and running at a reduced temperature setting.
- For longer periods, the entire system should be drained.
BOILER RESTART
To restart the boiler, when directed in the listed fault messages (see section
4) press the “Restart” button. The boiler will repeat its ignition sequence.
If the boiler still fails to start consult a Gas Safe Registered Engineer.
MAINS POWER OFF
To remove all power to the boiler the mains power switch must be turned off.
SYSTEM WATER PRESSURE
The system pressure gauge, behind the drop down door, indicates the central
heating system pressure. If the pressure is seen to fall below the original
installation pressure of 1-2 bar over a period of time and continue to fall
then a water leak may be indicated. In this event re-pressurise the system as
shown below. If unable to do so or if the pressure continues to drop a Gas
Safe Registered Engineer.
THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR
UNDER THIS CONDITION.
POINTS FOR THE BOILER USER
Note. In line with our current warranty policy we would ask that you check
through the following guide to identify any problems external to the boiler
prior to requesting a service engineers visit. Should the problem be found to
be other than with the appliance we reserve the right to levy a charge for the
visit, or for any pre-arranged visit where access is not gained by the
engineer.
FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660 BOILER
RESTART PROCEDURE – To restart boiler press the restart button
CONDENSATE DRAIN
- This appliance is fitted with a siphonic condensate trap system that reduces the risk of the appliance condensate from freezing. However should the condensate pipe to this appliance freeze, please follow these instructions:
- If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer for assistance.
- If you do feel competent to carry out the following instructions please do so with care when handling hot utensils. Do not attempt to thaw pipework above ground level.
- If this appliance develops a blockage in its condensate pipe, its condensate will build up to a point where it will make a gurgling noise prior to locking out displaying “Ignition Lockout” on the display. If the appliance is restarted it will make a gurgling noise prior to it locking out displaying “Ignition Lockout” on the display.
- To unblock a frozen condensate pipe;
- Follow the routing of the plastic pipe from its exit point on the appliance, through its route to its termination point. Locate the frozen blockage. It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow. This could be at the open end of the pipe, at a bend or elbow, or where there is a dip in the pipe in which condensate can collect. The location of the blockage should be identified as closely as possible before taking further action.
- Apply a hot water bottle, microwaveable heat pack or a warm damp cloth to the frozen blockage area. Several applications may have to be made before it fully defrosts. Warm water can also be poured onto the pipe from a watering can or similar. DO NOT use boiling water.
- Caution when using warm water as this may freeze and cause other localised hazards.
- Once the blockage is removed and the condensate can flow freely, restart the appliance. (Refer to “To Start the boiler”)
- If the appliance fails to ignite, call your Gas Safe Registered engineer.
Preventative Solutions
- During cold weather, set the central heating temperature knob (B) to “MAX”, (Remember to return to original setting once cold spell is over).
- Place the heating on continuous and turn the room thermostat down to 15ºC overnight or when unoccupied. (Return to normal after cold spell).
GENERAL INFORMATION
BOILER PUMP
The boiler pump will operate briefly as a self-check once every 24 hours,
regardless of system demand.
MINIMUM CLEARANCES
Clearance of 165 mm (6 1/2”) above, 100 mm (4”) below, 2.5 mm (91/8”) at the
sides and 450 mm (17 3/4”) at the front of the boiler casing must be allowed
for servicing.
BOTTOM CLEARANCE
Bottom clearance after installation can be reduced to 5 mm This must be
obtained with an easily removable panel, to enable the system pressure gauge
to be visible and to provide the 100 mm clearance required for servicing.
SERVICE REQUEST FUNCTION
When the boiler has been installed for more than 1 year the following message
will appear on screen:
Press “Restart” to clear this message.
ESCAPE OF GAS
-
Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999.
-
Ensure that;
- All naked flames are extinguished
- Do not operate electrical switches
- Open all windows and doors
CLEANING
For normal cleaning simply dust with a dry cloth. To remove stubborn marks and
stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use
abrasive cleaning materials.
MAINTENANCE
The frequency of servicing will depend upon the installation condition and
usage but should be carried out at least annually by a Gas Safe Registered
Engineer.
TROUBLESHOOTING
DISPLAY FUNCTIONS – NORMAL OPERATION MODE
NORMAL OPERATION SCREENS
WITHOUT OUTSIDE SENSOR
WITH OUTSIDE SENSOR
The display scrolls through a maximum of 3 messages under any operational
condition, as shown above
Note. The temperatures shown below are for illustration purposes only.
The measured temperatures will be shown on the boiler.
DISPLAY FUNCTIONS – FAULT MESSAGES
Technical Training
Our Expert Academy offer a range of training options designed and delivered by
our experts in heating.
For details please visit: expert-academy.co.uk.
ABOUT COMPANY
- Registered Office
- Ideal Boilers Ltd., National Avenue, Hull, East Yorkshire, HU5 4JB
- Tel 01482 492251 Fax 01482 448858
- Registration No. London 322 137
- EU Authorised Representative:
- Atlantic SFDT
- 44 Boulevard des Etats-Unis, 85 000 La Roche-Sur-Yon, France
- +33 (0)2 51 44 34 34
- Ideal Technical Helpline: 01482 498663
- Ideal Consumer Helpline: 01482 498660
- Ideal Parts: 01482 498665
- idealheating.com