FORTINET FortiGate 50G SFP POE Series Bluetooth Low Energy Module User Guide
- August 9, 2024
- FORTINET
Table of Contents
FortiGate 50G SFP POE Series Bluetooth Low Energy Module
“`html
Specifications:
- Product Name: FortiGate 50G SFP POE Series
- Models: FG-50G-SFP-POE, FG-51G-SFP-POE
- Power: AC Power Cable, DC Power Adapter
- Connectivity: Ethernet Ports, SFP Port
- Max PoE: Up to 60W
Product Usage Instructions:
Setup:
FortiExplorer Go:
- Install FortiExplorer Go on your device.
- Enable Bluetooth on your device.
- Follow the on-screen instructions for setup.
GUI Setup:
-
Connect Port 1 to your computer using the provided Ethernet
cable. -
Open a browser and go to https://192.168.1.99.
CLI Setup:
- Connect a console cable to the Console Port.
- Open a Terminal app and set the configuration to
9600-8-N-1.
Usage:
Default Login:
- URL: https://192.168.1.99
- Username: admin
- Password: leave blank
FortiGate Cloud:
Login to https://fortigate.forticloud.com using your Fortinet
credentials. Click Add FortiGate and enter the Cloudkey for
additional features.
Frequently Asked Questions (FAQ):
Q: How do I reset the FortiGate device?
A: Press and hold the BLE/RESET button on the
front panel to perform a system reset.
Q: What is the default IP address for GUI access?
A: The default IP address for GUI access is
https://192.168.1.99.
“`
QuickStart Guide
FortiGate 50G SFP POE Series
FG-50G-SFP-POE, FG-51G-SFP-POE
FG-50G-51G-SFP-POE-QSG-20240523.indd 1
5/23/2024 10:31:48 AM
The Essentials
FortiCare
Register your device to activate FortiCare Support at
https://support.fortinet.com
GUI
1 Connect Port 1 to an Ethernet port or USB-RJ45 adapter on your computer
using the provided Ethernet cable
2 Open a browser to https://192.168.1.99
CLI
1 Connect a console cable (not included) to the Console Port 2 Open a Terminal
app using 9600-8-N-1
Default Login
https://192.168.1.99 Username: admin Password: leave blank
Fortinet Documents Library
For getting started documentation, admin guides, up-to-date hardware manuals
and reference resources, visit https://docs.fortinet.com/
FortiGate Cloud
Experience simplified cloud provisioning, security analytics, remote access,
hosted log retention and reporting at https://fortigate.forticloud.com
FortiExplorer Go
Rapidly provision, deploy and manage your Fortinet Security Fabric Platform,
free on iOS and Android: https://docs.fortinet.com/product/fortiexplorer-go/
2
FG-50G-51G-SFP-POE-QSG-20240523.indd 2
5/23/2024 10:31:48 AM
Package Contents
FortiGate 50G SFP POE Series
FG-50G-SFP-POE, FG-51G-SFP-POE
1x FortiGate Device 1x AC Power Cable 1x Ethernet Cable
1x QuickStart Guide 1x DC Power Adapter
FG-50G-51G-SFP-POE-QSG-20240523.indd 3
3
5/23/2024 10:31:49 AM
Setup
FortiExplorer Go
Install FortiExplorer Go
Enable Bluetooth
Follow the on-screen instructions
GUI
Port 1
UhtsNteporsn:P/a/a1ms9se2w:.1a6od8rdm.1.9in9
Ethernet Cable
If Static IP: 192.168.1.1/24
4
FG-50G-51G-SFP-POE-QSG-20240523.indd 4
5/23/2024 10:31:49 AM
CLI
Console Port
USB Console Cable (available for purchase)
Speed (default): 9600
Data bits:
8
Stop bits:
1
Parity:
None
Flow Control: None
FortiGate Cloud
Login to https://fortigate.forticloud.com using your Fortinet Credentials,
then click Add FortiGate and enter the Cloudkey
WAN port
Ethernet Cable
Internet
FG-50G-51G-SFP-POE-QSG-20240523.indd 5
5
5/23/2024 10:31:50 AM
Front FG-50G-SFP-POE Series
FortiGate 50G SFP POE
BLE/RESET
BLE
PWR STATUS HA Signed Firmware
1
2
3
1 BLE / RESET Press to enable BLE; press and hold for system reset
Blue: BLE connected Flashing Blue: BLE in discovery Off: BLE not connected
2 Signed Firmware BIOS Security Level
Controlled by Signed Firmware Switch, see Admin Guide at
https://docs.fortinet.com Green: Security Level 2 (default) Amber: Security
Level 1 Red: Security Level 0
3 PWR
Green: Power detected Off: Power not detected
STATUS Green: Operating normally Flashing Green: Booting up Off: Device is off
HA Green: HA enabled (normal) Amber: HA enabled (failover) Off: HA disabled
6
FG-50G-51G-SFP-POE-QSG-20240523.indd 6
5/23/2024 10:31:50 AM
MAX PoE 1
2
A WAN2 WAN1 SFP
LINK/ACT
PoE+
BLE
PoE+
4
5
4 MAX PoE (up to 60W)
Red: Max PoE power reached Off: PoE+ available
Ethernet Ports LINK/ACT
Green: Connected Flashing Green: Data activity Off: Not connected
SFP Port LINK/ACT Green: Connected at 1 Gbps Flashing Green: Data activity
Off: No link established
5 BLE Antenna
PoE+
Green: Supplying PoE Off: Not supplying PoE
FG-50G-51G-SFP-POE-QSG-20240523.indd 7
7
5/23/2024 10:31:50 AM
Rear FG-50G-SFP-POE Series
Signed Firmware
USB
CONSOLE
SFP
1
2
3
4
1 Signed Firmware Switch 2 USB 3.0 Port (USB-A) 3 CONSOLE Port (RJ-45) CLI management 4 SFP Port (SFP)
WAN1
W
8
FG-50G-51G-SFP-POE-QSG-20240523.indd 8
5/23/2024 10:31:50 AM
WAN2
A
2
1
PoE+
5
DC+54V
6
5 Ports (5x RJ-45) WAN1, WAN2(PoE+), A FortiLink(PoE+), 2(PoE+), 1(PoE+) 6 Power Input 54V DC, 100-240V AC, 50/60Hz adapter
FG-50G-51G-SFP-POE-QSG-20240523.indd 9
9
5/23/2024 10:31:50 AM
Cautions and Warnings
Environmental specifications
Ambient operating temperature: 0°C to 40°C
Refer to specific Product Model Data Sheet for Environmental Specifications
(Operating Temperature, Storage Temperature, Humidity, and Altitude)
Référez à la Fiche Technique de ce produit pour les caractéristiques
environnementales (Température de fonctionnement, température de stockage,
humidité et l’altitude).
Safety
Battery Risk of explosion if the battery is replaced by an incorrect type.
Do not dispose of batteries in a fire. They may explode. Dispose of used
batteries according to your local regulations. IMPORTANT: Switzerland: Annex
4.10 of SR814.013 applies to batteries.
Batterie Risque d’explosion si la batterie est remplacée par un type
incorrect. Ne jetez pas les batteries au feu. Ils peuvent exploser. Jetez les
piles usagées conformément aux réglementations locales. IMPORTANT: Suisse:
l’annexe 4.10 de SR814.013 s’appliquent aux batteries.
This product is intended to be supplied by a Listed pluggable A via Class I
external power supply adapter by means of a power cord connected to a socket-
outlet with earthing connection.
Ce produit est destiné à être alimenté par un adaptateur d’alimentation
externe de classe I par l’intermédiaire d’un cordon d’alimentation enfichable
de classe A qui doit être branché à une prise de courant avec terre.
Grounding — To prevent damage to your equipment, connections that enter from
outside the building should pass through a lightning / surge protector, and be
properly grounded. Use an electrostatic discharge workstation (ESD) and/or
wear an anti-static wrist strap while you work. In addition to the grounding
terminal of the plug, on the back panel, there is another, separate terminal
for earthing.
Mise à la terre — Pour éviter d’endommager votre matériel, assurez-vous que
les branchements qui entrent à partir de l’extérieur du bâtiment passent par
un parafoudre / parasurtenseur et sont correctement mis à la terre. Utilisez
un poste de travail de décharge électrostatique (ESD) et / ou portez un
bracelet anti-statique lorsque vous travaillez. Ce produit possède une borne
de mise à la terre qui est prévu à l’arrière du produit, à ceci s’ajoute la
mise à la terre de la prise.
This product has a separate protective earthing terminal provided on the back
of the product in addition to the grounding terminal of the attachment plug.
This separate protective earthing terminal must be permanently connected to
earth with a green with yellow stripe conductor minimum size # 22AWG and the
connection is to be installed by a qualified service personnel.
Ce produit a une borne de mise à la terre séparé sur le dos de l’appareil, en
plus de la borne de mise à la terre de la fiche de raccordement. Cette borne
de mise à la terre séparée doit être connecté en permanence à la terre avec un
conducteur vert avec la taille bande jaune de minimum # 22AWG et la connexion
doit être installé par un personnel qualifié.
Caution: This equipment is to be used in a Network Environment 0 per IECTR
62101. This product is connected only to PoE networks without routing to the
outside plant.
Attention: Ce matériel doit être utilisé dans un Environnement Réseau 0 par
IECTR 62101. Ce produit est uniquement connecté aux réseaux PoE sans
installation externe de routage.
10
FG-50G-51G-SFP-POE-QSG-20240523.indd 10
5/23/2024 10:31:50 AM
Regulatory Notices
Federal Communication Commission (FCC) USA
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received;
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in
residential installation. This equipment generates, uses, and can radiate
radio frequency energy, and if it is not installed and used in accordance with
the instruction manual, it may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna. Increase the separation between
the equipment and receiver. Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. Consult the dealer or
an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
Innovation, Science and Economic Development (ISED) Canada This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-
exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le
fonctionnement.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps.
This radio transmitter (Contains IC: 7280B-110T17) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (Contains IC: 7280B-110T17) a été approuvé par ISED pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.
Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec une autre antenne ou transmetteur.
Antenna No.
1
Manufacturer Joymax
Model IHF-2120MPX9-W018
Antenna Type Monopole
Connector iPex MHF1
Antenna Peak Gain 1.53 dBi for 2.4GHz(BLE)
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
The product transmits within the frequency ranges and less than or equal to
the power listed below: 2402-2480MHz less than 10dBm
This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body.
11
FG-50G-51G-SFP-POE-QSG-20240523.indd 11
5/23/2024 10:31:50 AM
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations
of software, firmware and hardware) provided by Fortinet or Fortinet’s
authorized partners to the end-customer directly for use within the EU or
countries that have implemented the EU Directives and/or spectrum regulation.
Any Fortinet products not obtained directly from Fortinet or Fortinet’s
authorized partners may not comply with EU Directives and Fortinet makes no
assurances for such products.
2014/53/.
Cesky Tento produkt je v souladu se smrnicí 2014/53/EU.
Dansk Dette produkt er i overensstemmelse med direktiv 2014/53/EU.
Deutsch Dieses Produkt entspricht der Richtlinie 2014/53/EU.
Eesti See toode vastab direktiivile 2014/53/EL.
English This product is in compliance with Directive 2014/53/EU.
Español Este producto cumple con la Directiva 2014/53/UE.
2014/53/.
Français Ce produit est conforme à la Directive 2014/53/UE.
Hrvatski Ovaj proizvod je u skladu s Direktivom 2014/53/EU.
Italiano Questo prodotto è conforme alla Direttiva 2014/53/EU.
Latviski Sis produkts atbilst Direktvai 2014/53/ES.
Lietuvi Sis gaminys atitinka direktyv 2014/53/ES.
Malti Dan il-prodott huwa konformi mad-Direttiva 2014/53/UE.
Magyar Ez a termék megfelel a 2014/53/EU irányelvnek.
Nederlands Dit product is in overeenstemming met Richtlijn 2014/53/EU.
Norsk Dette produktet er i samsvar med direktiv 2014/53/EU.
Polski Ten produkt jest zgodny z dyrektyw 2014/53/UE.
Português Este produto está em conformidade com a Diretiva 2014/53/UE.
Rumunski Acest produs este în conformitate cu Directiva 2014/53/UE.
Slovensky Tento produkt je v súlade so smernicou 2014/53/EÚ.
Slovensko Ta izdelek je v skladu z Direktivo 2014/53/EU.
Suomi Tämä tuote on direktiivin 2014/53/EU mukainen.
Svenska Denna produkt överensstämmer med direktiv 2014/53/EU.
Note: The full Declaration of Conformity for this product is available in the
link below: https://site.fortinet.com/ProductRegulatory/EU
Voluntary Control Council for Interference (VCCI) Japan
Product Safety Electrical Appliance & Material (PSE) Japan
(PSE)
12
FG-50G-51G-SFP-POE-QSG-20240523.indd 12
5/23/2024 10:31:51 AM
Bureau of Standards Metrology and Inspection (BSMI) Taiwan
The presence conditions of the restricted substance (BSMI RoHS table) are
available at the link below: (RoHS Table) https://www.fortinet.com/bsmi
1762 (02) 27961666
National Telecommunications Commission (NCC) Taiwan
NCC
UK Conformity Assessed (UKCA) United Kingdom
The product transmits within the frequency ranges and less than or equal to
the power listed below: 2402-2480MHz less than 10dBm
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment
Regulations 2017
The full Declaration of Conformity for this product is available in the link
below: https://site.fortinet.com/ProductRegulatory/UK
FG-50G-51G-SFP-POE-QSG-20240523.indd 13
13
5/23/2024 10:31:51 AM
14
FG-50G-51G-SFP-POE-QSG-20240523.indd 14
5/23/2024 10:31:51 AM
FG-50G-51G-SFP-POE-QSG-20240523.indd 15
15
5/23/2024 10:31:51 AM
May 23, 2024
Copyright © 2024 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®,
FortiCare® and FortiGuard®, and certain other marks are registered trademarks
of Fortinet, Inc., and other Fortinet names herein may also be registered
and/or common law trademarks of Fortinet. All other product or company names
may be trademarks of their respective owners. Performance and other metrics
contained herein were attained in internal lab tests under ideal conditions,
and actual performance and other results may vary. Network variables,
different network environments and other conditions may affect performance
results. Nothing herein represents any binding commitment by Fortinet, and
Fortinet disclaims all warranties, whether express or implied, except to the
extent Fortinet enters a binding written contract, signed by Fortinet’s SVP
Legal and above, with a purchaser that expressly warrants that the identified
product will perform according to certain expressly-identified performance
metrics and, in such event, only the specific performance metrics expressly
identified in such binding written contract shall be binding on Fortinet. For
absolute clarity, any such warranty will be limited to performance in the same
ideal conditions as in Fortinet’s internal lab tests. Fortinet disclaims in
full any covenants, representations, and guarantees pursuant hereto, whether
express or implied. Fortinet reserves the right to change, modify, transfer,
or otherwise revise this publication without notice, and the most current
version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit
https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
FG-50G-51G-SFP-POE-QSG-20240523
FG-50G-51G-SFP-POE-QSG-20240523.indd 16
5/23/2024 10:31:51 AM