FORTINET FG–50G-DSL FortiGate 50G DSL User Guide

August 7, 2024
FORTINET

FORTINET FG–50G-DSL FortiGate 50G DSL User Guide

The Essentials

FortiCare

Register your device to activate FortiCare Support at https://support.fortinet.com

GUI

  1. Connect Port 1 to an Ethernet port or USB-RJ45 adapter on your computer using the provided Ethernet cable
  2. Open a browser to https://192.168.1.99

CLI

  1. Connect a console cable (not included) to the Console Port
  2. Open a Terminal app using 9600-8-N-1

Default Login

https://192.168.1.99
Username: admin
Password: leave blank

Fortinet Documents Library

For getting started documentation, admin guides, up-to-date hardware manuals and reference resources, visit https://docs.fortinet.com/

FortiGate Cloud

Experience simplified cloud provisioning, security analytics, remote access, hosted log retention and reporting at https://fortigate.forticloud.com

FortiExplorer Go

Rapidly provision, deploy and manage your Fortinet Security Fabric Platform, free on iOS and Android: https://docs.fortinet.com/product/fortiexplorer-go/


Package Contents

FortiGate 50G DSL
FG-50G-DSL 

  • **1x FortiGate Device

**

  • 1x QuickStart Guide

  • 3x AC Adapter Plugs (US, EU, UK)

  • 1x DC Power Adapter

  • 1x Ethernet Cable

  • 1x DSL Cable

Setup

FortiExplorer Go

  • Install FortiExplorer Go


  • **Enable Bluetooth

**

  • Follow the on-screen instructions

GUI

CLI

FortiGate Cloud

Login to https://fortigate.forticloud.com using your Fortinet Credentials, then click Add FortiGate and enter the Cloudkey

Front FG-50G-DSL

  1. BLE / RESET Press to enable BLE; press and hold for system reset

    • Blue: BLE connected
    • Flashing Blue: BLE in discovery
    • Off: BLE not conne
  2. Signed Firmware BIOS Security Level Controlled by Signed Firmware Switch, see Admin Guide at https://docs.fortinet.com

    • Green: Security Level 2 (default)
    • Amber: Security Level 1
    • Red: Security Level 0
  3. PWR

    • Green: Power detected

    • Off: Power not detected
      STATUS

    • Green: Operating normally

    • Flashing Green: Booting up

    • Off: Device is off
      HA

    • Green: HA enabled (normal)

    • Amber: HA enabled (failover)

    • Off: HA disabled

  4. Ports LINK/ACT

    • Green: Connected
    • Flashing Green: Data activity
    • Off: Not connected
  5. BLE Antenna
    LINK/ACT

    • Green: DSL connected

    • Flashing Green: DSL activity

    • Off: DSL not connected
      xDSL

    • Green: VDSL connection

    • Amber: ADSL connection

    • Off: No DSL connection
      SPEED

    • Green: 1 Gbps

    • Amber: 100 Mbps

    • Off: 10 Mbps or not connected

Rear FG-50G-DSL

  1. Power Input 12V DC, 100-240V AC, 50/60Hz adapter
  2. USB 3.0 Port (USB-A)
  3. CONSOLE Port (RJ-45) CLI management
  4. Signed Firmware Switch
  5. DSL Port (RJ-11)
  6. Ports (5x RJ-45) WAN, A – FortiLink, 3, 2, 1

Cautions and Warnings

Environmental specifications

Ambient operating temperature: 0°C to 40°C

Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)

Safety

Battery – Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. They may explode. Dispose of used batteries according to your local regulations. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.

This product is intended to be supplied by a Listed pluggable A via Class I external power supply adapter by means of a power cord connected to a socket- outlet with earthing connection

Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning / surge protector, and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap while you work. In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing

This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size # 22AWG and the connection is to be installed by a qualified service personnel.

Warning: Equipment intended for installation in Restricted Access Location.

Disconnect ES2 (TNV) circuit connector before removing cover.

IMPORTANT SAFETY INSTRUCTIONS – When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following

  • Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool.
  • Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
  • Do not use the telephone to report a gas leak in the vicinity of the leak.
  • Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for possible special disposal instructions

SAVE THESE INSTRUCTIONS

CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed or CSA Certified Telecommunication Line Cord.

Regulatory Notices

Federal Communication Commission (FCC) – USA

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2.  this device must accept any interference received; including interference that may cause undesired operation

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co located or operating in conjunction with any other antenna or transmitter.

This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

This equipment complies with ANSI TIA/EIA/968-B and Part 68 of the FCC rules and the requirements adopted by the ACTA. On the base of this equipment is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.

This equipment uses the following USOC jacks: RJ11.

A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details.

The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total REN, contact the local telephone company. The REN for this product is separately shown on the label and also part of the product identifier that has the format US: AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3).

If you experience trouble with this equipment, for repair or warranty information, please refer to Fortinet’s End User License Agreement which set forth the terms and limitation of Fortinet’s product warranty and contact the following address and phone number for additional information.

Fortinet, Inc.
899 Kifer Road, Sunnyvale, CA 94086 USA
1-866-393-9960 (US and Canada)
1-613-725-2466 (International)
http://www.fortinet.com

It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges.

This equipment may not be used on coin service provided by the telephone company. Connection to party line service is subject to state tariffs.

Innovation, Science and Economic Development (ISED) – Canada

This Class B digital apparatus complies with Canadian ICES-003.

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This  equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

This radio transmitter (Contains IC: 7280B-110T17 ) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.

This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.

Antenna
No.| 1
---|---
Manufacturer| Joymax
Model| IHF-2120MPX9-W018
Antenna Type| Monopole
Connector| iPex MHF1
Antenna Peak Gain| 1.53 dBi for 2.4GHz(BLE)

NOTICE: This product meets the applicable Industry Canada terminal technical specifications. This is confirmed  by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not guarantee the equipment will operate to the user’s satisfaction.

NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is 0.1. The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.

European Conformity (CE) – EU

This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

The product transmits within the frequency ranges and less than or equal to the power listed below:

2402-2480MHz less than 10dBm

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Simplified EU Declaration of Conformity

This declaration is only valid for Fortinet products (including combinations of software, firmware and hardware) provided by Fortinet or Fortinet’s authorized partners to the end-customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet’s authorized partners may not comply with EU Directives and Fortinet makes no assurances for such products.

Note: The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/EU

UK Conformity Assessed (UKCA) – United Kingdom

The product transmits within the frequency ranges and less than or equal to the power listed below:

  • STANDARD: Bluetooth
  • FREQUENCY RANGE: 2402-2480MHz
  • TRANSMIT POWER: Less than 10dBm (EIRP)

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

This product is in compliance with Statutory Instrument 1206 Radio Equipment Regulations 2017

The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK

Read User Manual Online (PDF format)