PRESSALIT 3000 Height Adjustable Changing Table Installation Guide
- August 7, 2024
- PRESSALIT
Table of Contents
PRESSALIT 3000 Height Adjustable Changing Table
Specifications:
- Product Name: Pressalit 3000 Height Adjustable Changing Table
- Available Versions: Adult Graphite Gray, Adult Sapphire Blue, Child Graphite Gray, Child Sapphire Blue
- Product Numbers: R8592318301, R8592318299, R8592313301, R8592313299
- EAN Codes: 5708590374161, 5708590374154, 5708590374147, 5708590374130
- Installation Environment: Indoor use in a wet environment (e.g., bathroom)
Product Usage Instructions
Installation Location:
This product is designed for indoor use in wet environments.
Ensure the installation location matches the product’s IP rating. Consider
temperature, humidity, and atmospheric pressure requirements.
Assembly and Installation:
Follow the assembly instructions provided. Connect components (hand control
unit, motor, control box, power cable) as shown.
Ensure connectors are securely attached.
Connection to Mains Supply:
Follow the configurations to connect to the power supply.
Replace the plug if necessary with an IP-rated one. Always isolate the circuit
before connecting to the mains supply.
Mounting Surfaces:
- Concrete >B25
- Solid Brick >= Mz12
- Solid Sand Lime Brick >= Hlz12
- Aerated Concrete P4
- Drywall water-resistant with different reinforcements
FAQs:
-
Q: Can the changing table be used outdoors?
A: No, this product is designed for indoor use in wet environments only. -
Q: How do I ensure a secure connection to the mains supply?
A: Always isolate the circuit before connecting the product to the mains supply. Follow the provided configurations for safe connection. -
Q: What is the warranty on this product?
A: Please contact MAX-Ability, Inc. at 800-577-1555 or info@max- ability.com for warranty information.
Adult
Graphite Gray: R8592318301 – EAN: 5708590374161
Sapphire Blue: R8592318299 – EAN: 5708590374154
Previous version: R8520, R8539
Child
Graphite Gray: R8592313301 – EAN: 5708590374147
Sapphire Blue: R8592313299 – EAN: 5708590374130
Previous version: R8516, R8534R
Subject to change without further notice.
Mounting Instruction
Please read and carefully follow these instructions. Find the product number
on the product label and ensure that these assembly instructions match your
product.
WARNING: Failure to comply with these instructions may result in
accidents involving serious personal injury or the product being damaged.
- If you suspect that any individual parts may be damaged, contact your Pressalit dealer or service provider. Do not remove, attempt to repair or install parts yourself, unless directed to do so by Pressalit or its agents.
- No modification of this equipment is allowed without express authorization from Pressalit.
- These instructions must be followed, and the product must be installed professionally by a qualified person; e.g. a licensed plumber, in order to avoid personal injury or property damage while using the product.
- Pressalit cannot be held liable for injury to persons or damage to property caused by faulty mounting.
Installation location
This product is designed for indoor use in a wet environment, such as a bathroom or washroom. It may only be used in an environment corresponding to the system’s IP rating.
Ensure that the installation location environment also complies with the following operating parameters of the product:
Environmental factor | Operating range |
---|---|
Temperature | 5°C to 40°C ( 41°F to 104°F) |
Relative humidity | 20% to 90% @ 30°C (86°F) (condensation free) |
Atmospheric pressure | 700 to 1060 hPa |
WARNING: Medical electrical equipment needs special precautions regarding
electromagnetic compatibility (EMC) and needs to be installed and put into
service in accordance with the EMC information (provided in your product’s
operating instructions). It is unlikely that the user will encounter problems
with the product because of inadequate electromagnetic compatibility. However,
electromagnetic immunity is always relative and standards anticipate
environments of usage. Portable and mobile RF communications equipment can
affect medical electrical equipment. When the product is connected to the
local mains power supply, we recommend the use of electromagnetic shielding
and similar preventative measures to avoid conducted emissions.
When choosing an installation location, ensure that there will be adequate
space for movement of—and access to—the product.
Assembly and installation
Mount the product in accordance with the illustrations in this assembly
instruction. Connect the product components—hand control unit, motor, control
box and power cable—to each other as shown. Ensure that the connectors are
pressed in as far as possible into their corresponding sockets.
Connection to the mains supply
There is a range of potential configurations to connect the product to the
mains power supply. See pages with . The product is supplied with a plug
attached, but this may need to be replaced with an IP-rated plug and socket
combination appropriate to the location of the socket relative to moisture, or
alternatively the product may be hardwired to a mains supply.
WARNING: Ensure that the circuit on the mains supply side is isolated
from power while connecting the product to the mains supply.
- The product must be connected to the mains supply and a protective earth connection by a qualified electrician in accordance with IEC 60601-1 and IEC 60364-7, as well as any locally applicable standards.
- Ensure that the voltage of the local mains supply to be connected is compliant with that stated on the label on the product.
- To ensure protection by electrical separation, the product must be supplied by a mains supply circuit that does not supply power to any other equipment, unless it incorporates a residual current protective device (RCD) with a rated residual operating current not exceeding 30 mA. The circuit must be grounded using a protective earth connection and able to be isolated from mains supply by means of a switch installed in a wall or cabinet.
- The integrity of the external protective earthing system must be verified.
- The installer must verify that the protective earth terminal of the control box is connected to the external protective earthing system.
- Ensure that location of the mains isolation switch or coupling is easy to access and use.
- External cables need to be fixed in such a way that users cannot stumble and injure themselves.
Troubleshooting
If the product does not function, check that that all cables are securely
connected, and that the electrical circuit is powered. A more detailed
troubleshooting guide can be found in the product’s operation and maintenance
manual. Contact your Pressalit agent, if assistance is needed when installing
the product.
Concrete anchors included at no additional charge.
International protection rating: IPX6
Water projected in powerful jets — from a nozzle up to 12.5 mm in size —
against the product from any direction shall have no harmful effects.
Please note: components are included for various installation
scenarios. Please disregard any unnecessary parts.
| |
---|---|---
Child Size (R8592313)| Product weight: 171 lbs| Weight capacity: 440 lbs
Adult Size (R8592318)| Product weight: 182 lbs| Weight capacity: 440 lbs
US Load bearing installation recommendations
- Pressalit can only be held responsible for installations carried out by Pressalit’s own installers.
- Pressalit can not be held responsible for reinforcements made in a faulty manner.
- The below recommendations are based on experience and internal test results.
- The below recommendations are to be considered as guidelines only.
- Subject to alteration without further notice.
This advisory document shows the maximum load capacity for individual bolts
and other types of anchors that can be used for fixing Pressalit’s products to
the wall.
The maximum load capacities shown below are per bolt/anchor and must be
considered in relation to the information provided for the product that is
being fitted. The information specific to the product will show how great the
load is on each fixing point when the product is used at its recommended safe
working load.
Only if the load on each fixing point of a given product is less than the
maximum load capacity of the type of bolt/anchor under consideration, should
the bolt/anchor in question be used.
E.g.
One might wish to fit an adult changing table 3000 to an aerated concrete
wall:
Maximum load
Maximum load: 440 lbs.
When the bench is loaded with 440 lbs, each mounting bolt supports 57 lbs.
Each fixing point is here carrying a load of 57 lbs, and the bolts typically
recommended for aerated concrete (Ø10, M8, M10) all have a maximum load
capacity that is higher than 57 lbs, so they can all be used.
Please refer to installation drawings and specification pages (go to max-
ability.com) for further information about which
types of bolts/anchors are recommended on specific wall types.
MAX-Ability provides concrete anchors at no additional charge.
Other fixing kits should be ordered separately.
Choose the appropriate anchor for your wall
Reinforcement of wall with 1.5-2” wood
Reinforcements of walls should always comply with national standards.
Reinforcement of wall with plywood
Reinforcements of walls should always comply with national standards.
Reinforcement of wall with steel
Reinforcements of walls should always comply with national standards.
Wall cross-section
Documents / Resources
|
PRESSALIT 3000 Height Adjustable Changing
Table
[pdf] Installation Guide
R8592318301, R8592318299, R8592313301, R8592313299, 3000 Height Adjustable
Changing Table, 3000 Table, Height Adjustable Changing Table, Height
Adjustable Table, Height Changing Table, Table
---|---
References
- Ability Office Ability Software
- Adult Changing Tables - Max-Ability | Special Needs Changing Tables
- Pressalit | Toilet seats and solutions for kitchens and bathrooms - Pressalit