PRESSALIT R8478 Adult Changing Table User Manual
- June 4, 2024
- PRESSALIT
Table of Contents
- Mounting instruction
- Operational signage
- Symbols used in this manual
- Specific safety
- General safety
- Product label
- Intended use
- Operating environment
- Versions
- Operating instructions
- Height adjustment
- Cleaning
- Disinfection
- Maintenance
- Troubleshooting
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PRESSALIT R8478 Adult Changing Table
The guarantee covers faults or defects in material or manufacture within a
period of 5 years. Products are subject to minor technical modifications and
design deviations. E.&O.E.
Mounting instruction
| A mounting instruction is included with the product. It can also be
downloaded from www.pressalitcare.com.
---|---
Operational signage
| An operational signage is included with this product. It can also be
downloaded from www.pressalitcare.com.
---|---
Symbols used in this manual
The following symbols are used in this manual as well as the associated documentation supplied with the product.
WARNING indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also be used to alert
against unsafe practices.
IMPORTANT indicates important information about handling and use of the
product.
NOTICE is used to address practices not related to personal safety.
| Hand injury warning
---|---
| Electricity or potentially dangerous voltage.
| Head injury warning.
Specific safety
- Never leave a person lying on the changing table without supervision.
- Always be careful when moving a person to and from the table.
General safety
- Read and understand the manual completely before use. Keep the manual close to the unit.
- Comply with this manual to avoid accidents involving serious personal injury.
- Never use or handle this product in other ways than are specified in this manual, as this can put your safety at risk and cause damage to the product.
- Make sure that everyone who is to install or use the product and its systems has the necessary information and access to this manual.
-
Please comply with these instructions to avoid the product becoming damaged or destroyed.
-
Do not perform repairs, disassembly, or assembly operations, extensions, re-adjustments or modifications to this product. These must be carried out by Pressalit or by persons authorized by Pressalit only.
-
Never allow children to operate this product unless under supervision.
The product is not intended for play. -
Never use the product if it is defective or damaged. Do not use a defective product before it has been repaired.
- The information in this manual is based on correct fitting of the product in accordance with our Assembly instruction.
- Pressalit cannot be held liable if the product is used in any way which differs from that described in the guide.
- We reserve the right to amend this manual without prior notice.
Product label
- Article number
- Production date
- Maximum user weight
- Consult manual for use
- Safe working load
- Mains voltage
- Frequency
- Maximum power consumption
- IP class
- Name and address of manufacturer
- Consult manual for use
- Consult the manual for important cautionary information such as warnings and precautions.
- Duty cycle. The motor on height-adjustable products can be used for a maximum of 2 minutes of continuous operation, followed by 18 minutes pause.
- Type B applied part Part of the product in normal use necessarily comes into physical contact with the patient to perform its function. The product complies with requirements of IEC 60601-1 to provide protection against electric shock.
- GS1-128 barcode
- Product weight
- Do not dispose as unsorted municipal waste. The product should be collected separately and returned to the designated recycling service.
- This product does not contain any of the hazardous substances mentioned in the Council Directive 2011/65/EC on RoHS.
- This product is CE-marked in accordance with the European Medical Device Directive 93/42/EEC, including amendments incorporated in Directive 2007/47/EEC. It also complies with all relevant requirements in the Council Directive 2006/42/EC (of 17 May 2006) on machinery and with Council Directive 2011/65/EC (of 8 June 2011) on RoHS. A declaration of conformity can be found at www.pressalitcare.com.
The product label ① is placed on the wall mount.
Intended use
This product is intended for bathing a person who is unable to stand up or sit down. The person is lying horizontally on the bench.
Intended operator profile
The product is to be used by personnel trained in health care and trained in
washing a person in their care.
Intended user profile
The product can be used by all – adults, children, young, old, whose weight
does not exceed the maximum load of 175 kg / 385 lbs.
Operating environment
For indoor use in a wet environment, such as a bathroom or wash room.
The product is intended to be used at room temperature, in a stand-alone
environment, in private homes, nursing homes and hospitals under normal
working conditions.
Salt and chloride have a corrosive effect on the products components and will
cause a decrease in the life expectancy of the product The damaging effects
can, however, be reduced if the product is showered with tap water on a daily
basis.
Versions
R8478
With removable mesh cover
R8592418000
With coated canvas mattress
R8592418 (US)
R8478000-93 (US)
120V|
Power Plug Type
---|---
Operating instructions
Support the bench using your hand or body when folding it down, to avoid the risk of damage
The built-in gas cylinders make it easy to fold the bench up against the wall after use
| Take care to avoid injury to hands when in the vicinity of closing
mechanical parts ①.
---|---
To pull the (optional) safety rail up: Release the lock ② and pull the safety rail ③ from the underside of the bench, and swing it upwards. The safety rail will automatically lock into position.
To fold the safety rail away: Release the lock 2 and swing the safety rail down to the underside of the bench. The safety rail will automatically lock into position.
Height adjustment
When the bench is installed at the correct height, it can be adjusted between
300 and 1000 mm (11.81 and 39.37 inches) above the floor.
The height adjustment is controlled by the wired remote control unit.
Press and hold the Up button to raise the bench, and press and hold the Down
button to lower the bench.
| Make sure
that there is no objects under the nursing bench when operating the height
adjustment system.
---|---
|
Never let a person lie on the nursing bench without the mesh cover/canvas in place. The tray under the pads is for water collection only. It is not to be used as a bathtub. Risk of injury to the user and damage to the product.
---|---
Cleaning
Clean the nursing bench after each use. Use ordinary soapy water. Rinse off with fresh water and dry with a soft cloth.
The frame with the mesh cover ① can be removed for cleaning.
The mesh cover can be zipped off and washed in regular washing machine at max
70o C.
Dry the water collection tray.
- Do not use an autoclave or other type of steam cleaner.
- Avoid aggressive cleaning agents containing acids or chloride.
- Never spray the nursing bench directly with a high pressure cleaner.
- Avoid use of aggressive, abrasive, corrosive or chloride-based cleaning or disinfecting products.
Disinfection
When using the nursing bench for multiple patients, it is necessary to both clean and disinfect the nursing bench between uses on different patients to prevent the risk of cross infection.
A list of suitable cleaning agents and disinfectants can be found at www.pressalitcare.com
Always read the material safety data sheet (MSDS) and supplied instructions of the cleaning, disinfecting or de-scaling agent and comply with instructions for safe use, dilution, rinsing, drying, handling and storage of the agent.
Maintenance
Expected service life of the nursing bench is 10 years, provided that maintenance is carried out as described below:
It is recommended on a weekly basis to run the motors on the product to their maximum positions by raising the bench to its full height, and then lowering it to its lowest position, so that the internal parts are lubricated.
It is recommended that service inspection is done once a year.
Service inspection
-
Check the hinges ① on the bench and the safety rail ②.
Tighten if necessary. -
Check the mesh cover ③ for damage and replace if necessary.
-
Check the drain pipe connections ④ , and check and clean the water trap (if fitted).
| Disconnect mains before removing the covers.
---|---
Remove the upper and lower retaining screws ⑤ on the lift unit cover and carefully remove the cover.
- Check the wall brackets ⑥ and tighten if necessary.
- Oil moving parts with WD40, especially the sliding brackets 7 .
- Check all electrical connections to the control box ⑧.
- Check the chain wheel ⑨ for wear.
- Oil the chain ⑩.
- Put the unit cover back again and tighten the retaining screws.
Troubleshooting
Symptom | Cause | Action |
---|---|---|
The nursing bench does not stay in upright position. | One or more gas | |
cylinders are defective. | Contact Pressalit A/S or your local dealer. | |
The product will not work, even though the remote control is used correctly. | ||
Fault in power supply. | Check that all wires and plugs are intact and |
correctly connected.
Contact Pressalit A/S or your local dealer.
The water does not run out of the water collection tray.| Adjustment screws
too high or too low.| Adjust the adjustment screws ① ****.
The nursing bench runs up and down unevenly.| The sliding brackets are not
properly lubricated.| Oil the sliding brackets as described under
“Maintenance”.
Contact MAX-Ability for any issues or questions.
Technical data
Max load | 175kg / 385 lbs |
---|---|
Materials | Powder laquered stainless steel Plastics (PVC, Polystyrene) |
Dimensions (width x length) | R8468: 875 mm x 1800 mm / 34.44 x 70.86 inches |
R8478: 899 mm x 1800 mm / 35.39 x 70.86 inches
Weight| R8468: 67 kg / 148 lbs
R8478: 73 kg / 161 lbs
IP class| The product has an ingress protection class rating of IPX6. The
product may not be immersed in water, but is designed to withstand powerful
jets (12.5 mm nozzle) of water from any direction.
Power specifications
Max consumption| 70 W
Voltage| Mains connection: 230V/120V/100V
Frequency| 50/60 Hz
Current| 3.7 A
Verify your purchase details before carrying out repairs so you don’t void
your warranty:
We guarantee all product components against manufacturing defects for five
years, and parts repair/labor for one year, from the invoice date. In most
instances the affected parts are replaced, not repaired.
Parts damaged due to improper product assembly, installation, or procedure;
lack of recommended maintenance including cleaning; or lost after delivery
cannot be included in this warranty.
References
- Pressalit | Toilet seats and solutions for kitchens and bathrooms - Pressalit
- Pressalit | Toilet seats and solutions for kitchens and bathrooms - Pressalit
- Pressalit | Toilet seats and solutions for kitchens and bathrooms - Pressalit