Honeywell T6360 Room Thermostat User Manual

June 13, 2024
Honeywell

Honeywell T6360 Room Thermostat

Product Information

  • Product Name: Room Thermostat T6360
  • Features:
    • Dual diaphragm temperature sensing element
    • Suitable for surface or switch box mounting
    • Heat anticipator for close temperature control
    • Change-over contact switching (cooling loads)
    • Double insulated
  • Options:
    • Temperature setback model
    • Tamper resistant model
    • Model with indicator lamp
    • Setting dial marked 1 to 5
    • High current rated model
    • Range stops
  • Application: The T6360 is a mains voltage Room Thermostat designed to give automatic temperature control of domestic wet central heating systems. It can be used to directly switch a circulating pump or boiler, or to operate spring return and motor open/motor close zone valves. The T6360 can switch electrical heating loads up to 10A. It can also be used for cooling applications.
  • Specification:
    • Voltage Rating: 230VAC, +/-10%, 50…60Hz
    • Switch Rating Terminal 3: 10A resistive, 3A inductive
    • Switch Rating Terminal 4: 6A resistive, 2A inductive
    • Switch Type: Single pole, double throw (SPDT)
    • Storage Conditions: Humidity: 10 to 90% RH, non-condensing
    • Standards: CE marked, EC Directive: EN60730-1 (1995), EN55014-1 (1997), EN55014-2 (1996)
    • Dimensions (mm): 84
  • Ordering Specification:
    • T6360B1028: Standard model complete with heat anticipator and RFI suppressor
    • T4360B1015: High current rated version with SPST switching and rated at 16A (resistive). Without heat anticipator
    • T6360B1069: As standard model but with tamper resistant cover and setting dial
    • T6360B1036: As standard model but with indicator lamp on front cover which is lit on a call for heat
    • T6360B1085: As standard model but with setting dial marked 1 to 5
    • T4360E1018: Model with temperature setback heater complete with anticipator heater and RFI suppressor

Product Usage Instructions

  1. The T6360 thermostat must be located where it is not subjected to extraneous heat gains, direct sunlight, or draughts.
  2. Fix the thermostat using the supplied fixing screws for either surface or flush mounting box.
  3. Wiring:
    • For T6360B model: Connect the heating load to Terminal 3 (10A max) and Terminal 4 (6A max).
    • For T4360E model: Connect the setback heater to Terminal 3 (10A max) and Terminal 4 (6A max).
    • For T4360B model: Connect the heating load to Terminal 3 (16A max).
  4. Ensure the voltage rating of the thermostat matches your electrical system (230VAC, +/-10%, 50…60Hz).
  5. Do not expose the thermostat to humidity exceeding 90% RH (non-condensing).
  6. Follow the CE marked standards and EC Directives during installation.

FEATURES

  • Dual diaphragm temperature sensing element
  • Suitable for surface or switch box mounting
  • Heat anticipator for close temperature control
  • 10 to 30˚C setpoint range
  • Change-over contact switching (cooling loads)
  • Double insulated

OPTIONS

  • Temperature setback model
  • Tamper resistant model
  • Model with indicator lamp
  • Setting dial marked 1 to 5
  • High current rated model
  • Range stops

APPLICATION

The T6360 is a mains voltage Room Thermostat designed to give automatic temperature control of domestic wet central heating systems. It can be used to directly switch a circulating pump or boiler, or to operate spring return and motor open/motor close zone valves. The T6360 can switch electrical heating loads up to 10A.
The T6360 thermostat can also be used for cooling applications.

Installation

The T6360 thermostat must be located where it is not subjected to extraneous heat gains, direct sunlight or draughts.
Fixing screws are supplied for either surface or flush mounting box.

Ordering Specification

  • T6360B1028
    Standard model complete with heat anticipator and RFI suppressor

  • T4360B1015
    High current rated version with SPST switching and rated at 16A (resistive). Without heat anticipator

  • T6360B1069
    As standard model but with tamper resistant cover and setting dial

  • T6360B1036
    As standard model but with indicator lamp on front cover which is lit on a call for heat

  • T6360B1085
    As standard model but with setting dial marked 1 to 5

  • T4360E1018
    Model with temperature setback heater (fixed at 6°C) and SPST switching, complete with anticipator heater and RFI suppressor

  • F42007562-001
    Accessory footprint for use when replacing T6060 thermostats

  • F42006646-001
    Bag assembly containing 20 range stops and installation instructions

  • F42007110-001
    Opaque tamperproof dial cover

  • TG510A1001
    Lockable, clear plastic thermostat cover. Backplate and spare keys inc

Specification

  • Voltage Rating : 230VAC, +/-10%, 50…60Hz
  • Switch Rating Terminal 3 : 10A resistive, 3A inductive Terminal 4 : 6A resistive, 2A inductive
  • Switch Type : Single pole, double throw (SPDT)
  • Temperature Setting Range : 10 to 30°C
  • Temperature Control Accuracy : ± 0.5°C at 3°K/hour with anticipator
  • Storage Conditions : -20 to 55°C
  • Humidity : 10 to 90% RH, non-condensing
  • Standards : CE marked
  • EC Directive : EN60730-1 (1995), EN55014-1 (1997), EN55014-2 (1996)

Dimensions (mm)

Honeywell-T6360-Room-Thermostat-fig-2

Wiring

Honeywell-T6360-Room-Thermostat-fig-3

© Honeywell Control Products and Systems, Issue 10, 4.7
Downloaded from www.Manualslib.com manuals search engine

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals