victron energy M10 DC Busbars with Integrated Battery Monitor and Main Fuse Holder Owner’s Manual

August 6, 2024
victron energy

victron energy M10 DC Busbars with Integrated Battery Monitor and Main

Fuse Holder

victron-energy-M10-DC-Busbars-with-Integrated-Battery-Monitor-and-Main-Fuse-
Holder-PRODUCT

Product Usage Instructions

  • Installation:
    • Ensure the power supply voltage falls within the range of 9 – 70 Vdc.
    • Connect the Lynx Shunt VE. Can to the appropriate system voltage of 12, 24, or 48V.
    • Securely fasten the connections using M8 or M10 screws.
  • Fuse Installation:
    • Purchase a CNN fuse separately.
    • Refer to the Fusing section in the Lynx Shunt VE. Can manual for detailed instructions on fuse installation.
  • Connection to GX Device:
    • Utilize the provided RJ45 VE. Can terminators when connecting to a GX device for communication.
    • Ensure proper connection of the VE. Can cables.

FAQs

  • Q: What is the purpose of the Lynx Shunt VE? Can?
    • A: The Lynx Shunt VE. Can function as a busbar with integrated battery monitoring and a main fuse holder, serving as part of the Lynx Distribution system for efficient power management.
  • Q: What is the recommended fuse type for the Lynx Shunt VE? Can?
    • A: The Lynx Shunt VE. The can is designed to hold a CNN fuse. This fuse needs to be purchased separately for installation.

Busbar Integrated Battery Monitoring

  • The Lynx Shunt VE.Can contain a positive and negative busbar, a battery monitor, and a fuse holder for the main system fuse. It is part of the Lynx Distribution system.
  • The Lynx Distributor has a power LED.
  • The Lynx Shunt VE.Can can communicate via VE. Can with a GX device.
  • The Lynx Shunt VE. Can ship with two RJ45 VE. Can terminators, be used when connecting to a GX device?
  • The Lynx Shunt VE. The can is designed to hold a CNN fuse. The fuse needs to be purchased separately. For more info see section Fusing in the Lynx Shunt VE. Can manual.

The Lynx Distribution System

  • The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, battery monitoring, and/or Lithium battery management.
  • For more information also see the DC Distribution Systems product page.

The Lynx Distribution System consists of the following parts:

  • Lynx Power In – A positive and negative busbar with 4 connections for batteries or DC equipment.
  • Lynx Distributor – A positive and negative busbar with 4 fused connections for batteries or DC equipment together with fuse monitoring.
  • Lynx Shunt VE. Can – A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE. Can communication for monitoring and setup with a GX device.
  • Lynx Smart BMS – For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor that is driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE. Can communication for monitoring with a GX device and the VRM portal.

Lynx Shunt VE.Can

Lynx Shunt VE.Can without cover

RJ45 VE. Can terminator

The Lynx modules: Lynx Power In, Lynx Distributor, Lynx Shunt VE.Can and Lynx Smart BMS

victron-energy-M10-DC-Busbars-with-Integrated-Battery-Monitor-and-Main-Fuse-
Holder-FIG-1 \(4\)

SPECIFICATION

Lynx Shunt VE.Can|
---|---
POWER
Supply voltage range| 9 – 70 Vdc
Supported system voltages| 12, 24 or 48V
Reverse polarity protection| No
Current rating| 1000Adc continuous
Power consumption| 60mA @ 12V

33mA @ 24V

20mA @ 48V

Potential free alarm contact| 3A, 30Vdc, 250Vac
CONNECTIONS
Busbar| M8 / M10
Fuse| M8
VE.Can| RJ45 and RJ45 terminator
Power supply connection to Lynx Distributor| RJ10 (an RJ10 cable ships with each Lynx Distributor)
Temperature sensor| Screw terminal
Relay| Screw terminal
PHYSICAL
Enclosure material| ABS
Enclosure dimensions (h x w x d)| 190 x 180 x 80 mm
Unit weight| 1.4 kg
Busbar material| Tinned copper
Busbar dimensions (hxw)| 8 x 30 mm
ENVIRONMENTAL
Operating temperature range| -40°C to +60°
Storage temperature range| -40°C to +60°
Humidity| Max. 95% (non-condensing)
Protection class| IP22

System Example

System example – Lynx Shunt VE. Can, Lynx Power In, Lynx Distributor, and lead acid batteries

  • This system contains the following components:
    • Lynx Power In with 4 paralleled 12V lead acid batteries.
    • Identical cable lengths for each battery.
    • Lynx Shunt VE. Can with the main system fuse and battery monitor.
    • Lynx Distributor with fused connections for inverter/charger(s), loads, and chargers. Note that additional modules can be added if more connections are needed.
    • Cerbo GX (or other GX device) to read out the battery monitor data.victron-energy-M10-DC-Busbars-with-Integrated-Battery-Monitor-and-Main-Fuse-Holder-FIG-1 \(5\)

A system with Lynx Shunt VE.Can, lead acid batteries, a Lynx Shunt VE.Can and a Lynx Distributor

CONTACT INFORMATION

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

victron energy User Manuals

Related Manuals