fischer KEYSTONE 6 Tactical Hub User Guide

August 2, 2024
Fischer

Fischer KEYSTONE 6 Tactical Hub

Specifications

  • Connector Interface
  • Electrical
  • Environmental
  • Material and Mechanical
  • Firmware
  • Dimensions

EASY CONNECTIVITY & EFFICIENT DATA & POWER MANAGEMENT FOR SOLDIER-WORN DIGITAL EQUIPMENT

  • Up to 100 W of power
  • USB 2.0 and SMBus data protocol
  • Connects to all Nett Warrior / NATO STANAG 4695 and 4851 standard components

For full information, please visit our website: fischerconnectors.com

Technical specifications

CONNECTOR INTERFACE

Pin Power ports (plugs) PAN/EUD ports (receptacles)

1

| VBATT: [10-20] V DC

5 A max

Power supply input

| VBATT: [10-20] V DC

5 A max

Power supply output

2| Ground| Ground
3| 5 V DC IN| 5 V DC OUT
4| USB+ / SMBus Data| USB+
5| USB- / SMBus Clock| USB-
6| NC| CC line

  • Only on RADIO/BATT port “
  • EUD port: INPUT/OUTPUT
  • EUD port only

ELECTRICAL

EUD / HOST

| VBATT output power| Unregulated

VBATT [10-20] V DC,

up to 5 A

---|---|---
USB power| Power delivery, Charge up to 1.5 A

PAN 1/2/3

| VBATT output power| Unregulated

VBATT [10-20] V DC,

up to 5 A

USB output power| Regulated 5 V DC, up to 2 A per port

BATT

| VBATT input power| Unregulated

VBATT [10-20] V DC,

up to 5 A

RADIO/BATT

| VBATT input power| Unregulated

VBATT [10-20] V DC,

up to 5 A

USB input power| 5 V DC power supply from radio

Communication protocol

| EUD, PANs| USB 2.0
BATT, RADIO/BATT| USB 2.0 and SMBus versions 1.0/1.1 compatible
Fault mode protection| Over current, over voltage, back-power

ENVIRONMENTAL

Temperature

| Storage| -40 °C to +55 °C
---|---|---
Operating| -32 °C to +49 °C

Altitude

| Storage| Up to +12,192 m
Operating| Up to +9,754 m
Rapid decompression| From +2,438 m

to +12,192 m

Sealing| IP68 -2m/24h
Shock| 40 G, 11 ms
Vibration| 7.7 Grms, 1 h per axis

Weather condition

|

Solar radiation, salt atmosphere, sand and dust, rain and water, fungus

EMI/EMC

| CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103, CS118 Level IV (ESD)

Validations performed per MIL-STD-810G and MIL-STD-461G

MATERIAL AND MECHANICAL

Housing material Aluminum
Weight 241 g (8.5 oz)

FIRMWARE



Security

| ■ Only booting signed software – verified using a SHA256 checksum and an ECC256 signature


■ Software update files are encrypted using an AES 256 encryption

---|---
Certification| FIPS 140-2/3 capable

DIMENSIONS

Electrical architecture

VBATT POWER DISTRIBUTION

VBATT OUT

  • A wide range of batteries supported, including. SMBus protocol
  • Unregulated VBATT distribution [10-20] V DC
  • Dual battery hot-swap functionality
  • Electrical fail-safe mechanism on all ports

5 V DC POWER DISTRIBUTION

  • Regulated 5 V Bus
  • USB-C bidirectional power delivery on EUD port
  • Radio 5 V DC power IN functionality on RADIO/BATT port

DATA DISTRIBUTION

  • EUD/HOST USB HUB upstream port
  • PANs, BATT, and RADIO/BATT USB downstream ports
  • Automatic detection between USB and SMBus on BATT and RADIO/BATT ports

Operating instructions

MOLLE MOUNT

POWERING KEYSTONE 6

  • The KEYSTONE 6 can be powered by a 10 to 20 V DC power source on the RADIO/BATT port, the BATT port, or both.
  • The Nett Warrior extension cable can be used to connect directly to a Nett Warrior-style battery or a battery adapter.

ENABLING THE DATA FLOW

  • To establish the data flow within the HUB, a host device must be connected to the EUD/HOST port.
  • Connect the End User Device (EUD) to the Fischer Nett Warrior plug to the USB type C cable.
  • With the Fischer EUD cable, devices with a USB-C interface can leverage the KEYSTONE 6’s built-in power delivery and be charged.

NOTE : EUD cables with integrated Power Delivery functionality are not compatible with KEYSTONE 6.

Keystone app instructions

LAUNCHING THE KEYSTONE APP

Press OK to enable communication between the HUB and the HOST once the EUD is connected.

KEYSTONE APP OVERVIEW
Intuitive graphic interface with all essential information directly accessible on one screen.

  • Press f1 or Menu and Settings (refer to p.19)
  • The icon indicates the internal microcontroller temperature
  • The KEYSTONE 6 has a self-diagnosis function. The STATUS OK icon will change to ALERTS when the HUB is malfunctioning. Press the alerts icon to list the different problems.

PANs STATUS

The power bar quickly indicates the amount of power consumed on the PAN. This visual indicator is completed by a measurement in Watts.

PAN output status:

  • Green light means power is enabled, no light means disabled
  • The visual differentiation between VBATT and 5 V DC is made by the size of the indicators

Press the PAN icon to:

  • Access the output control by toggling the VBATT and 5 V DC buttons
  • Display the voltage and current measurements of each output
  • Modify the PAN name by clicking on the text field

NOTE: 5 V DC can be disabled without cutting data communication.

EUD STATUS

The KEYSTONE 6’s built-in bidirectional power delivery function allows the EUD to be charged when the HUB is powered by an external source, typically a battery, but in the opposite case, the EUD can power the HUB with 5 V DC only.

The power meter indicates the sense of the energy flow:

Press the EUD icon to:

  • Display the voltage and current measurements of the power lines
  • Modify the EUD name by clicking on the text field

BATT AND RADIO/BATT STATUS
The light gray icon shows the power source in use. When it is a smart battery, in addition to the state of charge and the voltage level, the remaining operating time is displayed.

The type of battery is identified by a specific icon:

The following icon indicates that there is no connection to any power source on the considered port.

BATT AND RADIO/BATT STATUS

Press the BATT or RADIO/BATT icon when connected to a power source to access the following details:
The “Set as source” button allows the user to force the system to select a power supply.

The USE DEFAULT SOURCE button returns to the default selection logic:

  • In case the two connected power sources are of the same nature, the RADIO/BATT port is the default power source.
  • In case a smart battery and a simple DC voltage source are connected, the simple DC voltage source is the default power source.

In all cases, the hot-swap feature allows you to switch from one power supply to another without any power loss.
An alert threshold can be defined according to the battery charge level. The threshold is defined as follows:

  • in % for smart batteries
  • in Volts for DC sources

Once reached, the battery icon turns into orange

  • The activation of the logs allows to recording of all the parameters of energy consumption for post-mission analysis.
  • “AUTO CONNECT” will automatically enable communication with the HUB at connection without asking the user to confirm.
  • A night mode is available by pressing the DISPLAY THEME button.
  • When creating a profile, all current settings are saved and are associated with the newly created profile which automatically becomes the default profile.
  • Resetting the HUB will reboot the HUB, therefore data and power will be lost during the reboot cycle.
  • Resetting the KEYSTONE app will reset the HUB and return the system to initial factory settings. All profiles will be lost.

ATAK PLUG-IN

The KEYSTONE 6 can also be controlled through a plug-in in ATAK.

In ATAK the features have been reduced to the essential:

  • Power management of the PANs
  • Hot-swap function

LIMITATIONS OF USE

  1. This product and its accessories must be used for its intended purpose only. Failing to do so (or failing to comply) will void the warranty.
  2. Do not use it in an explosive atmosphere.
  3. Unused (or unmated) pigtails should be fastened to the vest and should not be left loose.
  4. Fischer Connectors SA is not responsible for any changes or modifications not expressly approved by Fischer Connectors SA for compliance. Such modifications could void the user’s authority to operate the equipment.

FCC STATEMENTS

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference,
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC ID: 2BBS9-HBK06
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Explore high-performance connectivity solutions fischerconnectors.com
© Fischer Connectors SA – All rights reserved 550312 – Version 1.3 – 08.2023 Changes without prior notice.

Explore high-performance
connectivity solutions
fischerconnectors.com

© Fischer Connectors SA – All rights reserved 550312 – Version 1.3 – 08.2023
Changes without prior notice

FAQ

  • Q: What is the maximum voltage for VBATT power distribution?
    • A: The VBATT power distribution supports a voltage range of 10-20 V DC.
  • Q: How can I securely update the firmware?
    • A: Firmware update files are encrypted using AES 256 encryption for security. Follow the provided instructions for firmware updates.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals