Brava Slim
USER MANUAL
To consult the documentation, visit our website www.sime.it https://www.sime.it/en/documentation- videos
Fonderie SIME S.p.A.
6332320 – 11/2021 – R0
TRANSLATION OF THE ORIGINAL INSTRUCTIONS –
SAFETY WARNINGS AND REGULATIONS
For the “SAFETY WARNINGS AND REGULATIONS” please refer to the information
provided in the relevant section of the “INSTALLATION AND MAINTENANCE MANUAL”.
Dear Customer, Thank you for purchasing a Sime Brava Slim boiler, a new-
generation low-temperature modulating device possessing technical and
performance characteristics capable of satisfying your space heating and
instant domestic hot water requirements with the utmost safety and with
limited running costs.
COMPLIANCE
Our company declares that Brava Slim boilers comply with the following
directives:
– Gas Appliances EU Regulation 2016/426
– Boiler Efficiency Directive 92/42/EEC
– Low Voltage Directive 2014/35/EU
– Electromagnetic Compatibility Directive 2014/30/EU
SYMBOLS
WARNING
To indicate actions which, if not carried out correctly, can result in injury
of a general nature or may damage or cause the appliance to malfunction; these
actions therefore require particular caution and adequate preparation.
ELECTRICAL HAZARD
To indicate actions which, if not carried out correctly, could lead to injury
of an electrical nature; these actions therefore require particular caution
and ade- quate preparation.
IT IS FORBIDDEN
To indicate actions which MUST NOT BE carried out.
CAUTION
To indicate particularly important and useful informa- tion.
CAUTION Fonderie SIME S.p.A. reserves the right to make improvements to
its products at any time without prior notice, without compromising their
essential characteristics. The graphic illustrations and/ or images in this
document may show optional accessories that vary according to the country in
which the appliance is used.
COMMISSIONING
1.1 Preliminary checks
Commissioning of the Brava Slim boiler must be carried out by professionally
qualified technicians, after which the boiler can operate automatically. It
may, however, be necessary for the user to start the appliance autonomously
without involving a technician: for example, after a holiday. First of all
check that the gas isolation and water system valves are open.
1.2 Ignition
After having carried out the preliminary checks, perform the following to
start the boiler:
– set the main system switch to “ON” in order for the display to show the
pressure level in the system during refilling
– make sure that the operating mode is set to “Stand-by”; if this is not the
case, press the button ****until “Stand-by” mode has been selected
– on the display (1), check that the heating system pressure when cold is
1-1.2 bar. If this is not the case, open the filling valve (2) and restore the
heating system pressure until the display (1) shows a reading of 1-1.2 bar
– close the filling valve (2)
– select the “SUMMER” operating mode by pressing and holding the ****button for at least 1 second. the value of the delivery sensor detected at that moment will appear on the display
– open one or more than one hot water tap. The boiler will work at maximum
power until the taps are closed.
Once the boiler has been commissioned in “SUMMER mode” “WINTER mode”
can be selected by pressing and holding the button ****for at least 1
second. The value of the delivery water temperature detected at that moment
will appear on the display. In this case it is necessary to adjust the air
thermostat/s to the required temperature or if the system has a chrono-
thermostat, check that this is “active” and adjusted.
1.3 Adjusting the heating temperature
If the heating temperature is to be increased or decreased, press the buttont
followed by the buttons + > or <- until the desired temperatureis reached.
The temperature can be set to between 20 and 80°C.
1.4 Adjusting the domestic hot water temperature
If the domestic hot water temperature is to be increased or decreased, press
the button followed by the buttons+ > or < – until the desired temperature
is reached. The temperature can be set to between 10 and 60°C.
1.5 Fault / malfunction codes
If a fault/malfunction is detected during boiler operation, the message “ALL”
will appear on the display followed by the fault code.
If you see alarm “02” (low water pressure in the system):
– on the display (1), check that the heating system pressure when cold is
1-1.2 bar. If this is not the case, open the filling valve (2) and restore the
heating system pressure until the display (1) shows a reading of 1-1.2 bar
– close the filling valve (2)
– press and hold the button ****for more than 3 seconds and check whether
normal operating conditions are restored.
If you see alarm “06” (no flame detected) and “07” (safety thermostat
intervention):
– press and hold the button ****for more than 3 seconds and check whether
normal operating conditions are restored.![sime Wall mounted boiler Brava Slim
- conditions](https://manuals.plus/wp-content/uploads/2023/08/sime-Wall- mounted-boiler-Brava-Slim-conditions.jpg)
If this operation is not successful, ONLY ONE MORE ATTEMPT can be made,
therefore:
– close the gas isolation valve
– set the main system switch to “OFF”
– contact the Personale Tecnico Abilitato.
CAUTION
Should you see an alarm not described here, contact a qualified technical
professional.
1.5.1 Maintenance request
When it is time to perform maintenance on the boiler, the symbol shows on the
display. Contact the technical assistance service to organise the necessary
work.
SHUTDOWN
2.1 Temporary shutdown
If the user wishes to interrupt boiler operation, press and hold the button
for at least one second, once if in “WINTER mode” or twice if in
“SUMMER mode” l. “ ****” will appear on the display.
ELECTRICAL HAZARD
The boiler will still be powered.
If the user is away temporarily, for a weekend, short trip etc and if the
outside temperature is at ZERO:
– press and hold the button once if in “WINTER mode” or twice if in
“SUMMER mode” ****to put the boiler into standby
– set the main system switch to “OFF”
– close the gas valve.
CAUTION
If the outside temperature might fall below ZERO, since the appliance is
equipped with an “antifreeze function”
– ONLY PUT THE BOILER INTO STAND-BY
– leave the main system switch set to “ON” (boiler is powered)
– leave the gas valve open.
2.2 Shutting down for long periods
If the boiler is to be left unused for a long period, the following operations
need to be carried out:
– press and hold the button for at least 1 second, once if in “WINTER
mode” or twice if in “SUMMER mode” l to put the boiler into stand-by “
****-” will appear on the display
– set the main system switch to “OFF”
– close the gas valve
– close the heating and domestic hot water isolation valves
– drain the heating and domestic hot water system if there is the risk of
freezing.
**CAUTION**
Contact the Personale Tecnico Abilitato if the procedure described above
cannot be easily carriedout.
MAINTENANCE
3.1 Adjustments
For the appliance to operate correctly and efficiently it is recommended that
the User calls upon theservices of a Professionally Qualified Technician to
carry out ANNUAL maintenance.
CAUTION
Maintenance interventions must ONLY be carried out by professionally qualified
personnel who will follow the indications provided in the INSTALLATION AND
MAINTENANCE MANUAL.
3.2 External cleaning
3.2.1 Cleaning the cladding
When cleaning the cladding, use a cloth dampened with soap and water or
alcohol for stubborn marks.
IT IS FORBIDDEN
**** to use abrasive products.
DISPOSAL
4.1 Disposal of the equipment (European Directive 2012/19/EU)
At the end of their life span, the appliance and electrical and electronic
devices coming from households or classifiable as household waste must be
delivered to appropriate waste collection systems, in accordance with the law
and with Directive 2012/19/EU. This product was designed and manufactured for
minimising its impact on the environment and on human health, but it contains
components that could be detrimental if managed improperly. The symbol
(crossed-out wheelie bin) depicted here and also appearing on your appliance
means that the appliance at the end of its life must be managed in accordance
with the law and treated as electrical and electronic waste. Before delivering
the appliance for its disposal, consult the applicable provisions of the laws
in force in the country where the appliance is used and get information on the
authorised waste disposal facilities by contacting the relevant local offices.
IT IS FORBIDDEN
dispose of the product with urban waste.
Fonderie Sime S.p.A – Via Garbo, 27 – 37045 Legnago (Vr)
Tel. +39 0442 631111 –
Fax +39 0442 631292 – www.sime.it
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>