Blue-White F-300M Acrylic Variable Area Flow Meters User Guide

July 31, 2024
Blue-White

Blue-White F-300M Acrylic Variable Area Flow Meters

Product Information

Specifications

  • Product Name: F-300 Acrylic Variable Area Flow Meters
  • Models : F-300, F-300M, D-300, U-300
  • Maximum Pressure: 50 PSI (5.17 bar)
  • Compatibility : Suitable for indoor and outdoor use
  • Flow Meter Calibration: Tested and calibrated for water only

Product Usage Instructions

Safety Instructions

  • CAUTION: Always wear eye protection when installing or removing flow meters.
  • Location: Meters are suitable for indoor and outdoor use.
  • Pressure: Do not exceed 50 PSI (5.17 bar) to avoid damage to the meter.

Pre-Installation

  • In the Box: Flow meter, Rubber gasket, 2 Clamps, Quick start guide
  • Tools Needed: Compatible piping (SCH 40 or SCH 80), Mounts and supports

Planning
Ensure the piping is straight horizontal or vertical SCH 40 or SCH 80. Mounts and supports must be sturdy enough to prevent vibration.

Suitability
Determine the suitability of the flow meter for your application. Flow meters are tested and calibrated for water only.

Installation

  1. Prepare: Install the flow meter downstream from the filter if possible with at least the minimum straight pipe dimensions.
  2. Install: Drill the pitot tube hole, insert the pitot tube, ensure flow direction, and tighten clamps.

Caring for Your Flow Meters

  • Troubleshooting
    If the meter fails to read, check for clogged openings in the pitot tube and ensure correct direction of flow.

  • Cleaning
    Clean the tapered tube with a soft bottle brush using a mild soap and water solution. Note the float’s position for re-assembly.

Warranty Information
F-300 flow meters are warranted for 1 year from the date of purchase. Proof of purchase is required for repair or replacement.

Contact Information
Contact us at +1 714-893-8529 or email customerservice@blue-white.com for any questions.

IMPORTANT Safety instructions

  • CAUTION

    • Follow these instructions before installing your flow meter to avoid failure.
    • Always wear eye protection when installing or removing flow meters.
  • LOCATION
    Meters are suitable for indoor and outdoor use.

  • PRESSURE
    Do not exceed 50 PSI (5.17 bar). High pressure and temperature will damage the meter.

F-300
Acrylic Variable Area Flow Meters

SCAN THE QR CODE

  • F-300
  • F-300M
  • D-300
  • U-300

PRE-INSTALLATION

Before you begin

  • In the Box
  • Flow meter
  • Rubber gasket
  • Clamp x2
  • Quick start guide

Tools Needed

  1. Drill
  2. Drill bit 5/8” (1”–4” flow meter)
  3. Drill bit 3/4” (6”–8” flow meter)
  4. Drill bit 16mm (all F-300M)
  5. Drill bit 1/4” (Optional pilot hole)
  6. Fine sandpaper (Optional)
  7. Felt pen
  8. Tape measure
  9. Flathead screwdriver
  • Compatibility
    Ensure the piping is either straight horizontal or vertical SCH 40 or SCH 80. (F-300M horizontal PN 10 or PN 16)

  • Planning
    Mounts and supports must be sturdy enough to support the plumbing and prevent vibration. Vibration and heavy loads will damage the meter.

  • Suitability
    It is the responsibility of the user to determine the suitability of the flow meter in their application. Flow meters are tested and calibrated for water only.

INSTALLATION

Step-By-Step

  1. Prepare
    To prevent debris from entering the meter, install the flow meter downstream from the filter if possible with at least the minimum straight pipe dimensions.
    *Minimum acceptable dimensions

  2. Install
    Drill the pitot tube hole in the top (12 O’clock position) of the horizontal pipe or anywhere around vertical pipe. Carefully remove all burrs. Insert the pitot tube, with the gasket in place, into the drilled hole. Ensure the flow direction is in the same direction of the flow arrow. Tighten the clamps alternately, a little at a time.

  3. Read
    Avoid imposing a sudden burst of flow to the meter. Solenoid valves may cause the float to impact the top float stop with destructive force. Always read float at top.

SCAN THE QR CODE

Video instruction

CARING

For your flow meters

  • Troubleshooting
    Should the meter fail to read, ensure the openings in the front and rear of the pitot tube are not clogged, that the pitot tube opening faces the direction of the flow.

  • Cleaning
    The tapered tube may be cleaned with a soft bottle brush. Use a MILD soap and water solution for cleaning purposes. Note the floats “up” position for re- assembly.

  • Winterize
    If installed outside, or if not being used for a period of time, we recommend removing themeter from the pipe, cleaning thoroughly, and storing it indoors for the winter. While the meter can withstand cold temperatures and outdoor conditions, expansion and contraction caused by freezing water can cause stress to the meter components that might result in cracking. Clean the meter inside and out prior to re-installing.

WARRANTY Information

LIMITED WARRANTY
Your Blue-White product is a quality product and is warranted for a specific time from the date of purchase (proof of purchase is required). The product will be repaired or replaced at our discretion. Failure must have occurred due to a defect in material or workmanship and not as a result of the operation of the product other than in normal operation as defined in the product manual. Warranty status is determined by the product’s serial label and the sales invoice or receipt. The serial label must be on the product and legible. The warranty status of the product will be verified by Blue-White or a factory- authorized service center.

F-300 flow meters are warranted for 1 year from the date of purchase (proof of purchase is required). The flow meter will be repaired or replaced at our discretion.

WHAT IS NOT COVERED

  • Freight to the factory, or service center.
  • Products that have been tampered with, or in pieces.
  • Damage resulting from misuse, carelessness such as chemical spills on the enclosure, abuse, lack of maintenance, or alteration which is out of our control.
  • Damage by faulty wiring, power surges, or acts of nature.
  • Damage that occurs as a result of: meter misalignment, improper installation, over tightening, use of non-recommended chemicals, use of non-recommended adhesives or pipe dopes, excessive heat or pressure, or allowing the meter to support the weight of related piping.

BLUE-WHITE does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of the use of its products. Failure must have occurred due to a defect in material or workmanship and not as a result of the operation of the product other than in normal operation as defined in the manual. Warranty status is determined by the product’s serial label and the sales invoice or receipt. The serial label must be on the product and legible. The warranty status will be verified by Blue-White or a factory-authorized service center.

PROCEDURE FOR IN-WARRANTY REPAIR
Warranty service must be performed by the factory or an authorized service center. Contact the factory or local repair center to obtain a RMA (Return Material Authorization) number. It is recommended to include a foot strainer and injection/check valve fitting since these devices may be clogged and part of the problem. Decontaminate, dry, and carefully pack the product to be repaired. Please enclose a brief description of the problem and proof of purchase. Prepay all shipping and insurance costs. COD shipments will not be accepted. Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair is completed, the factory pays for return shipping to the dealer or customer.

Have Questions?

SCAN THE QR CODE

blue-white.com/contact-us

P.N. #80000-700 F-300 QSG REV 3 20240613 & IS TIE 2015 SINCE Quality 1957

MADE IN THE USA

FAQ

Q: Can the flow meter be used for liquids other than water?
A: The flow meters are specifically calibrated for water only. Using them with other liquids may affect accuracy.

Q: What should I do if the meter fails to read?
A: Check for clogged openings in the pitot tube and ensure proper flow direction. Clean the tapered tube with mild soap and water.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>