SNLX Lithium Xero Batteries
“`html
Specifications:
- Brand: Invicta
- Model: Lithium Xero SNLX
- Battery Type: LiFePO4
- Capacity: [Specify the capacity]
- Operating Temperature: [Specify the temperature range]
- Dimensions: [Specify the dimensions]
Product Information:
Welcome to your new Invicta Lithium Xero LiFePO4 Battery. Please
read the instructions and warnings carefully to ensure optimal
performance.
Warnings For Operation:
[Include detailed warnings for safe operation of the
battery]
Tips For Operation:
[Provide tips on discharging and charging rates. Recommend
downloading the Invicta Legion Application for enhanced battery
management.]
Battery Appearance:
-
Heat Sink: The heat sink helps cool the
battery; avoid touching it during use to prevent burns. -
Pole Terminal: Identify positive and negative
terminals to prevent reversal; cover the terminals after connecting
power. -
Display Panel: Features a fault/running light,
SOC indicator lights, and a button for operation.
Battery Installation:
[Detailed steps on how to install the battery correctly]
Charging Your Battery:
[Instructions on how to charge the battery safely and
effectively]
Setting Up A Parallel or Series System:
[Guidance on setting up parallel or series connections with the
battery]
FAQ:
Q: How do I know if my battery is fully charged?
A: The battery display panel will indicate a full charge with
all SOC indicator lights lit.
Q: Can I connect multiple batteries in parallel?
A: Yes, you can set up a parallel system following the provided
instructions.
“`
INVICTA LITHIUM BATTERIES
Invicta Lithium Xero SNLX – User Manual
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Contents
Warnings For Operation
3
Tips For Operation
4
Battery Appearance
5
Box Contents
7
Battery Installation
8
Charging Your Battery
9
Setting Up A Parallel or Series System 10
Wired System Connection
12
BT System Connection
14
Communication Device Connection
15
Battery Recycling
16
Transportation and Storage
16
Warranty
16
Contact Details
16
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Welcome to your new Invicta LIthium Xero LiFePO4 Battery. Please read the
instructions and warning on this card carefully to ensure you get the most out
of your battery. Warnings For Operation
· Read this manual before use · Keep away from direct heat, high voltage and
direct sunlight. · Never short circuit the positive and negative terminals. ·
Never ship or store battery along with metal. · Never disassemble, alter or
drill the battery. · Avoid direct impact to the battery. · Never throw battery
· Never exceed the IP67 dust and water resistant rating · Never place the
battery in fire · Ensure charge rate is within the parameters of the battery ·
Do not exceed the discharge parameters of the battery · Do not reverse the
polarity of the battery · Do not place the battery upside down · Before
connecting the battery pack to your device, check the voltage and ensure that
they are within the limits of your device specifications. Failure to comply
with these specifications will void your warranty. · Keep exhaust valve and
heat-sink clear
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Tips For Operation
· To activate a Parallel or Series connection using the battery-to-battery CAN
cables Ensure that the reset button is press and held for 20seconds. Refer to
Parallel/Series section.
· To activate communication device – Ensure that the reset button is press and
held for 20seconds. Refer to Communication section
· Download Invicta Legion App for Battery Monitoring, Wired Parallel/Series
setup, and Communication Device setup. Refer to Invicta Legion Application
Section
· If the battery goes below the over-discharge protection voltage or the over-
discharge protection is activated, charge battery within 15 days.
· Battery must be charged within 6 months of receipt · Battery should be
maintenance charged every 3 months to extend life · Ideal storage temperature
20oC 35oC · Do not leave battery in low state of charge for long periods of
time. · Isolate battery from system if not in use for more than 7 days ·
Battery will enter hibination if not used for more then 15 days · Keep battery
away from high temperatures of 60oC or more · If battery shows signs of
deformation, heat or emits smell, immediately discontinue use. · The SNLX
battery has a passive balance feature which results in cells and battteries
discharging and charging at different rate
Download The Invicta Legion Application
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Battery Appearance
1. 2. 3.
4. 5.
6. 7.
8. 9.
Heat Sink
Pole Terminal
Display Panel
Power Switch
Label
Handle
Comms. Port
Ventilation Valve
Mounting Feet
1. Heat sink: The heat sink is a cooling component that benefits the battery
life. At the same time, the heat sink is a hot decoration that cannot be
touched by hand during battery use to avoid burns.
2. Pole terminal: Each battery has a positive and negative terminal. During
use, be sure to identify and avoid reversing the positive and negative poles.
After connecting the power line to the pole terminal, cover it with a
protective cover to prevent short circuits.
3. Display Panel: The battery display panel has one fault/running light, 4
SOC indicator lights, and one button: the usage method is as follows: RUN/ALM:
One red light, one yellow light, displayed in yellow when the battery is
normal; when there is a battery failure alarm or protection, it will display
in red.
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
4. Battery Power Switch: The battery power switch is used to turn the battery
on or off. When the battery is in the ON state, it indicates that the battery
BMS is in a normal state and can
5. Label: During use, matching the corresponding charger and loading
according to the label parameters is essential to avoid battery failure.
6. Handle: The handle is used to bear the weight of the battery. When lifting
the battery, observe the stability of the handle to avoid the battery falling
off.
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
7. Communication Port: There are two communication ports: one is Link in, and the other is Link out. Pay attention during use.
8. Pressure relief valve: The waterproof grade is IP67 because the battery is heating during charging and discharging, which leads to thermal expansion. Adding a pressure relief valve can prevent the air pressure inside the battery box from rising, resulting in dangerous accidents. Make sure that there is no other object around the pressure relief valve.
9. Installation bracket: Install the bracket to facilitate battery installation in vehicles. It is recommended to use M6 stainless steel screws to secure the battery. Only available on SNLX12V120BT batteries
Box Contents
SN
Item
QTY
1
Battery-to-battery 1
CAN Cable
2
Battery
1
3
Terminal Screw
2
4
Mounting Feet*
4
SPEC 500mm, M1 with 2 circular coomunicaions interfaces at each end SNLX M8 Feet and screws (SNLX12V120BT only)
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Battery Installation
· Remove the battery from the box ensuring it is undamaged and the correct
model · Record the serial number and register you battery
https://www.invictalithium.com.au/warranty-registration-2/ · Check you have
the right battery for your application · Check place of installation, ensuring
it is clean and ready · Ensure you have the right tools, equipment and PPE
· Ensure battery is off before connecting any cables, leads or accessories ·
Ensure the application and any accessories are off · Carefully lift and lower
the battery using the handles supplied · Do not over tighten any brackets,
nuts, bolts or terminals. · Hand tighten plus half turn is sufficient ·
Connect cables, leads, and accessories · Connect negative cables to negative
terminal and positive cables to positive terminal.
· If connecting in a parallel, series, or communication device (ie Victron
Cerbo GX) please refer to the section in this manual on how to do this.
· If connecting in parallel or series – never connect in master-slave
configuration. Doing so may void your warranty
· Turn on batteries only once all cables, leads and accesories are connected ·
Wait upto 15 seconds for batteries to complete self check and turn on · turn
on accessories · Open the Invicta Legion Application – ensure no protection
are active · If you wish to change to name of your battery the password is
1234. Please record the
serial number before doing this · If you are not using the battery we
recommend turning the battery off
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Charging Your Battery
· Always use a battery charger with a lithium profile that does not exceed the
charging specifications of the battery
· Charger must not contain Sulphation/Equalisation setting. If so then this
needs to be turned off.
· The charging table should be followed when charging
· Always use a battery charger with a lithium profile that does not exceed the
charging specifications of the battery
· Charger must not contain Sulphation/Equalisation setting. If so then this
needs to be turned off.
· The charging table should be followed when charging · Do not have batteries
sit on float charge for an extended period of time. · Please ensure your
charger is matched to the current rating of your battery and take
note of the recommended charge current in the batteries specification sheet
Normally half the batteries rated capacity. For example SNL12V100S
Recommended charge current = 50A. · We will only warrant the battery if a
Lithium (LiFePO4) profile charger has been used · For specifications for your
battery please visit invictalithium.com.au · If using solar it should utilise
a MPPT regulator that matches the battery specifications · If using a DC-DC
charger ensure it matches the battery specifications
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Setting Up A Parallel or Series System
· Before connecting batteries in series or parallel, pay attention to: a). The
batteries must be of the same model. When there are different models,
different capacities, and different voltage platforms, series and parallel
connections are not allowed; b). Ensure that all parallel wires are of
identical length; c). 0.5C charging is recommended, that is, charging current
= half the rated capacity of the battery d). Before connecting the batteries
in series and parallel, the batteries should be fully charged and balanced.
You can check whether the batteries are balanced by using the Invicta Legion
Application
Important Information 1. Before connecting in series or parallel, ensure the
batteries are off. 2. Once the batteries are off, connect the battery leads in
a series and/or parallel
configuration as shown below. Never master-slave a system and always adhere to
the max configuration 3. Connect your accessories and check all connections
are secure.
Parallel example: 2 x 12.8V100Ah System voltage: 12.8V System capacity:100Ah +
100Ah = 200Ah
Series example: 2 x 12V.8100Ah System voltage: 12.82=25.6V System capacity:
100Ah
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Simultaneous Series and Parallel: To series batteries allow simultaneous use
of batteries in series and parallel, with a maximum support of 4 series and 4
parallel applications. The connection method is: first in series, then in
parallel, which means that the batteries are connected in series to form a
high voltage and then in parallel to form a high capacity.
Series & Parallel Eg. 16 x 12.8V100Ah 4 in series & 4 in parallel System voltage: 12.8V x 4 = 51.2V System capacity: 100Ah x 4 = 400Ah System = 51.2V 400Ah
4. The batteries can communicate via a `Wired’ connection or Bluetooth
connection 5. the Wired connection utilises the battery-to-battery CAN cables
and is the
preferred method of communication. Below is the Max configuration allowed
depending on which method you use. 6. Extension cables are available for
purchase 7. To set up a parallel or series connection you will need to
download the Invicta legion Application 8. Follow the steps in the following
pages refering to the connection method you have chosen
Max Bluetooth Configuration S = Series / P = Parallel
12V System 1S + 16P 2S 1P 3S 1P 4S 1P
Max Wired Configuration S = Series / P = Parallel
12V System 1S + 16P 2S 4P 3S 4P 4S 4P
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Wired System Connection
Setup Use this system to connect and monitor multiple batteries in series
and/or parallel via a wired/CAN bus connection. This is the preferred method
when possible.
To set up a Wired system please follow the steps below.
1. Connect battery-to-battery Link cables. Only use approved Invicta Link
Cables for battery-to-battery connection.
2. Battery 1 – Link Out > Battery 2 – Link In 3. Battery 2 – Link Out >
Battery 3 – Link In etc. 4. If using a communication device this will connect
to the Link-In on Battery 1 5. Important!! Turn the batteries on in sequence
and wait 10 seconds for power to be
supplied. Press and hold reset button for 20sec. on Battery 1. Wait for lights
to run and stop. This will take approx 2 min. If lights flash, reattempt.
Communication line connection method:
!
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
6. Open Invicta Legion Application and press Wired System connection
7. Press the + sign and set the system name, voltage platform, series or
parallel connection and quantity of batteries in the system.
Max Configuration – S = Series / P = Parallel
12V System 1S + 16P 2S 4P 3S 4P 4S 4P
24V System 36V System 48V System
1S 4P
1S 4P
1S 4P
8. Press Select `Master Battery’ 9. Select Master Batter (Battery 1) 10.
Ensure the corresponding battery name is
connected to the corresponding position in the system 11. Ensure battery one
(Master) is in the first position, battery two is in the second position etc.
12. For example – in a four battery system, do not place battery three in the
first position. 13. Press save. 14. To change or remove the system, press
Reconfigure or Release.
15. Attention third party installers – After testing on your phone, it is
important to release the network and set it up on the customers phone during
hand over.
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
BT System Connection
Setup Use this system to connect and monitor multiple batteries in series or
parallel via a battery-tobattery Bluetooth connection. The user can set up
multiple systems and monitor individual batteries in the system. Users can
also connect and monitor multiple batteries via a wired connection, and is the
preferred method if possible. See Wired System Connection for this method
To set up a BT system please follow the steps below.
1. Open Invicta Legion Application and click BT System connection
2. Click the + sign and set the system name, voltage platform, series or
parallel connection and quantity of batteries in the system.
3. Select the corresponding battery name to the corresponding position in the
system
4. Ensure battery one is in the first position, battery two is in the second
position etc.
5. For example – in a four battery system, do not place battery three in the
first position.
6. Press save. To change or remove the system, press Re-configure or Release.
7. Attention third party installers – After testing on your phone, it is
important to release the network and set it up on the customers phone during
hand over.
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Communication Device Connection
Setup Use this connection method to set up a communication device such as a
Victron Cerbo GX.
1. Ensure you have the right cables to connect to the battery. You may need
our battery to inverter cable which is CAN-to-RJ45. These are sold seperately.
2. Connect the CAN connector to the Link-In port on Battery One 3. If setting
up in a parallel or series connection, do this now. 4. Ensure you setup using
a Wired Connection method using the
instructions in the pages before 5. Important!!! Press and hold the reset
button for 20 seconds wait
for the lights to run and stop. This will take approx 2 mins to complete. If
lights flash, reattempt 6. If you require special information on Victron set
up, please contact our Customer Service team on 1300 001 772
!
Communication line connection method:
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E info@spb.net.au W spb.net.au
INVICTA LITHIUM BATTERIES
Battery Recycling
Invicta Lithium® Xero lithium-ion batteries are recyclable and should not be
treated as household waste or landfill waste. If you need assistance in
recycling batteries, please get in touch with your dealer or Invicta Lithium.
Transportation and Storage
· During transportation, there should be no severe vibration, impact, or
compression, and it should be protected from sunlight and rain.
· Handle with care during loading and unloading, and strictly prevent falling,
rolling, and heavy pressure.
· The battery should be stored in a dry, clean, dark, and well-ventilated
indoor environment for a long time. The recommended storage temperature range
is 15~35 .
· The storage area should be free of harmful gases, flammable and explosive
materials, and corrosive chemicals.
Warranty
Invicta has a 7-year full replacement warranty when installed in an approved
application and when instructions in this manual have been followed. Please
refer to your warranty card or invictalithium. com.au and register your
battery to ensure your battery is in an approved application. A copy of the
warranty statement can be found at www.invictalithium.com.au/warranty-
statement/.
Contact Details
A range of resources can be found at invictalithium.com.au. This includes
specifications, product registration and our warranty statement. If you
require further assistance with your Invicta battery, please contact Sealed
Performance Batteries (SPB) on 1300 001 772 or info@spb.net.au. Invicta
Lithium is a brand and registered tradmark of Sealed Performance Batteries
(SPB), a company that has over 25 years experience in energy storage and are
located in Brisbane, Sydney and Melbourne. For more information on SPB please
visit spb.net.au
SPB Sydney Office: 2/28 Prime Drive, Seven Hills New South Wales, 2147 SPB
Melbourne Office: 3/35 Dunlop Road, Mulgrave, Melbourne, VIC, 3170 SPB
National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207 T 1300 001 772 E
info@spb.net.au W spb.net.au
References
- Invicta Lithium Batteries | LiFePO4 Lithium Batteries
- Batteries For All Applications | Sealed Performance Batteries
- Invicta Lithium Batteries | Warranty Statement
- Warranty & Registration - Invicta Lithium Batteries
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>