DynaLabs DYN-C-1000-SI Analog Capacitive Accelerometer Instruction Manual
- July 30, 2024
- Dynalabs
Table of Contents
DynaLabs DYN-C-1000-SI Analog Capacitive Accelerometer
Specifications
- Model: DYN-C-1000-SI
- Range [g]: 3, 5
Product Support
If at any time you have questions or problems with the DYN-C-1000-SI sensors, please contact a Dynalabs engineer at:
Phone: +90 312 386 21 89 (9 a.m. to 5 p.m., UTC +3)
E-mail: info@dynalabs.com.tr
Warranty
Our products are warranted against defective materials and workmanship for one year. Defects arising from user errors are not covered by the warranty.
Copyright
All copyrights of this manual belonging to Dynalabs products are reserved. It
cannot be reproduced without written consent.
Disclaimer
- Dynalabs Ltd. provides this publication “as is” without warranty of any kind, express or implied, including but not limited to, the implied warranties of merchantability or fitness for a particular purpose. This document is subject to change without notice, and should not be construed as a commitment or representation by Dynalabs Ltd.
- This publication may contain inaccuracies or typographical errors. Dynalabs Ltd. will periodically update the material for inclusion in new editions. Changes and improvements to the product described in this manual may be made at any time.
Introduction
Capacitive accelerometers are based on proven micro-electro-mechanical systems
(MEMS) technology. These capacitive accelerometers are reliable and long-term
stable. They have a DC response. The advantage of these sensors is their
outstanding temperature stability, high-frequency response, and low noise-high
resolution. These sensors have a reliable aluminum housing with IP68
protection class.
Dynalabs 1000SI series uniaxial accelerometers provide an ultra-low noise
performance from 0.7 to 1.2 μg/√Hz. These accelerometers provide excellent
bias and scale factor stability and a wide frequency range (±3dB) from 550 Hz
to 700 Hz.
DYN-C-1000-SI sensors offer the following options;
- Custom Cable Length (5m standard cable)
- Custom Housing Material
- Custom Connector
- Base plate (Optional)
General Information
Unpacking and Inspection
Dynalabs products provide adequate protection for undamaged products to be
transported. Document the damages that occur indirectly during the transport
and contact the customer representative.
System Components
The DYN-C-1000-SI has the following components:
- MEMS Sensor
- Calibration Certificate
- Product Manual
Specifications
Table 1: Specifications datasheet
Full-scale acceleration| (g)| 1003SI
± 3
| 1005SI
± 5
---|---|---|---
White Noise| (μg/√Hz)| 0.7| 1.2
Noise (Integrated over 0.1Hz to 100Hz)| (μg)| __
8
| __
13
Dynamic range (0.1Hz to 100Hz)| (dB)| __
108.5
| __
108.5
Scale Factor Sensitivity| (mV/g)| __
900
| __
540
Bandwidth (±3dB)| (Hz)| __
550
| __
700
Operating power consumption| (mW)| __
90
| __
90
Environmental
Table 2 Environmental specifications datasheet
Protection Level | IP 68 |
---|---|
Operating Voltage | 6 V – 40 V |
Operating Temperature | -40 °C to +100 °C |
Isolation | Case isolated |
Physical
Table 3 Physical specifications datasheet
Sensing Element | MEMS Capacitive |
---|---|
Housing Material | Aluminum or Steel |
Connector (Optional) | D-Sub 9 or 15 pin, Lemo, Binder |
Mounting | Adhesive or screw mount |
Base plate (Optional) | Aluminum or Steel |
Weight (without cable) | 15 g (aluminum) |
30 g (steel)
Outline Drawing
The dimensional properties of DYN-C-1000-SI sensors are given below.
Technical Drawings
Operation and Installation
General
The general sensor connector configuration is given below;
Cable Code/Pin Configuration:
- Red: V + Power supply voltage +6 to +40 VDC
- Black Ground Power GND
- X: Yellow: Signal(+) Positive, analog output voltage signal for differential mode
- Blue: Signal(-) Negative, analog output voltage signal for differential mode
WARNING
- Never connect the power supply and/or the power ground to yellow and/or blue cables.
- Never connect the power supply to the power ground. Always use a clean power source and check the voltage range.
Sensor Static Calibration Verification
Using gravity, voltage values are measured in the + and – gravity directions,
providing a value of ±1 g. The measurement should be made as follows;
- When the sensitivity value of 1000SI series sensors is used with the data acquisition system, the sensor shows +1 g with the effect of gravity in the direction of the arrow sign.
- When the sensor is in the opposite direction of the arrow, it shows -1 g with the effect of gravity.
Using gravity, the voltage values that provide 1 g in the + and – directions are measured and compared with the catalog value. The calibration value should be close to the catalog value with a 10% tolerance. Sensor catalog sensitivity values are given in Table 1.
Declaration of Conformity
This declaration of conformity is issued under the sole responsibility of the manufacturer. The product(s) are developed, produced, and tested according to the following EC- directives:
- 2014/35/EU – Low Voltage Directive (LVD)
- 2006/42/EU – Machinery Safety Directive
- 2015/863/EU – RoHS Directive
Applied standards:
- EN 61010-1:2010
- EN ISO 12100:2010
- MIL-STD-810-H-2019 (Test Methods: 501.7- High Temperature, 502.7- Low
Temperature, 514.8- Vibration, 516.8 – Shock)
DYNALABS MÜHENDİSLİK SANAYİ TİCARET LİMİTED ŞİRKETİ declares that abthe ove-
mentioned products meet all the requirements of the above-mentioned standards
and regulations.
Canan Karadeniz, General Manager
Ankara, 15.07.2021
FAQ
Warranty Information
- Q: What is covered under the warranty?
- A: Our products are warranted against defective materials and workmanship for one year. Defects arising from user errors are not covered by the warranty.
Copyright Information
- Q: Can this manual be reproduced?
- A: All copyrights of this manual belonging to Dynalabs products are reserved. It cannot be reproduced without written consent.
Disclaimer Notice
- Q: Is there a warranty on the information provided in this document?
- A: Dynalabs Ltd. provides this publication as is without warranty of any kind, express or implied.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>