Shelly Qubino QNSW-002P16EU 2 Channel Box Relay Controller User Guide
- July 29, 2024
- Shelly Qubino
Table of Contents
Shelly Qubino QNSW-002P16EU 2 Channel Box Relay Controller
Specifications:
- Product Name: Wave 2PM
- Model Number: B4223
- Input Voltage: 110-240 V AC / 24 V DC
- Version: 0.0.10
Product Information
The Wave 2PM is a device that allows remote control of two electrical devices such as bulbs, ceiling fans, and IR heaters. It can switch on/off two independent loads and measures their power consumption separately and collectively. The device is compatible with both switches and push-buttons.
**Installation Instructions
**
For AC Circuits:
- Connect both L terminals to the Live wire and the N terminal to the Neutral wire.
- Connect the first load circuits to the O1 terminal and the Neutral wire.
- Connect the second load circuits to the O2 terminal and the Neutral wire.
- Connect the first switch/push-button to the SW1 terminal and the Live wire.
- Connect the second switch/push-button to the SW2 terminal and the Live wire.
Adding (Inclusion):
With a Switch/Push-button:
Follow the specified steps for adding the device with a switch/push-button
as outlined in the user manual.
With the S Button:
Ensure to follow the correct procedure as described in the manual when
adding the device using the S button.
Removing (Exclusion):
With a Switch/Push-button:
- Connect the Device to a power supply.
- Check if the green LED is blinking in Mode 1 to proceed with removal.
With the S Button:
Refer to the manual for detailed steps on removing the device using the S
button.
Factory Reset:
With a Switch/Push-button:
- Connect the Device to a power supply.
- Toggle the switch/push-button connected to SW1 or SW2 terminal 5 times within 3 seconds.
Note: The factory reset process must be initiated within the first minute after connecting the device to power.
FAQ:
-
Q: What should I do if I lose the PIN Code for Security 2 (S2) adding?
A: If you lose the PIN Code, you will not be able to complete the Security 2 adding process. Make sure to keep the PIN Code safe and secure at all times. -
Q: Can I use mixed AC and DC circuits with the Wave 2PM device?
A: No, it is cautioned against using mixed AC and DC circuits with the Wave 2PM device. Only use one phase AC circuit for safe operation.
LEGEND
Device terminals:
- N: Neutral terminal
- L: Live terminals (110–240 V AC)
- O1: Load circuit 1 output terminal
- O2: Load circuit 2 output terminal
- SW1: Switch/push-button input terminal (controlling O1)
- SW2: Switch/push-button input terminal (controlling O2)
- +: 24 V DC positive terminal
- : 24 V DC ground terminals
- S: S button (Fig. 5)
Wires:
- N: Neutral wire
- L: Live wire (110-240 V AC)
- +: 24 V DC positive wire
- GND: 24 V DC ground wire
USER AND SAFETY GUIDE
2-circuit Z-Wave® smart switch with power measurement
READ BEFORE USE
This document contains important technical and safety information about the
Device, its safe use and installation.
CAUTION! Before beginning the installation, please read carefully and
entirely this guide and any other documents accompanying the Device. Failure
to follow the installation procedures could lead to malfunction, danger to
your health and life, violation of law or refusal of legal and/or commercial
guarantee (if any). Shelly Europe Ltd. is not responsible for any loss or
damage in case of incorrect installation or improper operation of this Device
due to failure of following the user and safety instructions in this guide.
TERMINOLOGY
Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave®
main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device
that serves as a central hub for a Z-Wave® smart home network. The term
“gateway” is used in this document.
S button – The Z-Wave® Service button, which is located on Z-Wave® devices and
is used for various functions such as adding (inclusion), removing
(exclusion), and resetting the device to its factory default settings. The
term “S button” is used in this document.
Device – In this document, the term “Device” is used to refer to the Wave 2PM
device.
ABOUT SHELLY QUBINO
Shelly Qubino is a line of innovative microprocessor-managed devices, which
allow remote control of electric circuits with a smartphone, tablet, PC, or
home automation system. They work on Z-Wave® wireless communication protocol,
using a gateway. When the gateway is connected to the internet, you can
control Shelly Qubino devices remotely from anywhere. Shelly Qubino devices
can be operated in any Z-Wave® network with other Z-Wave® certified devices
from other manufacturers. All mains operated nodes within the network will act
as repeaters regardless of vendor to increase reliability of the network.
Devices are designed to work with older generations of Z-Wave® devices and
gateways.
ABOUT THE WAVE 2PM
The Wave 2PM (Device) is a single product that enables remote control of two
electrical devices such as bulbs, ceiling fans, and IR heaters. It switches
(on/off) two independent loads and measures their power consumption separately
and in total. The Device is compatible with switches (default) and push-
buttons.
ELECTRICAL DIAGRAM (110-240 V AC / 24 V DC)
Refer to the schematics (Fig.1-4) in this user guide.
INSTALLATION INSTRUCTIONS
The Device can control various types of loads (e.g., bulbs). Each circuit can
support a load up to 10 A (with a total of 16 A for both circuits) and its
power consumption is measured individually and in total (AC only).
It can be retrofitted into standard electrical wall boxes, behind power
sockets and light switches or other places with limited space.
CAUTION! Danger of electrocution. Mounting/installation of the Device to
the power grid has to be performed with caution, by a qualified electrician.
- Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
- Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
- Do not connect the Device to appliances exceeding the given max. load!
- Do not shorten the antenna.
- RECOMMENDATION: Place the antenna as far away as possible from metal elements as they can cause signal interference.
- CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
- Do not install the Device where it can get wet.
- Do not use the Device if it has been damaged!
- Do not attempt to service or repair the Device yourself!
RECOMMENDATION: Connect the Device using solid single-core wires with
increased insulation heat resistance not less than PVC T105°C (221°F).
CAUTION! Before starting the mounting/installation of the De-vice, check
that the breakers are turned off and there is no voltage on their terminals.
This can be done with a phase tester or multimeter. When you are sure that
there is no voltage, you can proceed to connecting the wires.
If you want to use the Device with a push-button, refer to the Fig. 2 and Fig.
4. For a switch, refer to the Fig. 1 and Fig. 3.
CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC
circuits.
For AC circuits connect both L terminals to the Live wire and the N terminal
to the Neutral wire. Connect the first load circuits to the O1 terminal and
the Neutral wire. Connect the second load circuits to the O2 terminal and the
Neutral wire. Connect the first switch/push-button to the SW1 terminal and the
Live wire. Connect the second switch/push-button to the SW2 terminal and the
Live wire.
For DC circuits connect both terminals to the GND wire and the + terminal to
the Positive wire. Connect the first load circuits to the O1 terminal and the
Positive wire. Connect the second load circuits to the O2 terminal and the
Positive wire. Connect the first switch/push-button to the SW1 terminal and
the GND wire. Connect the second switch/push-button to the SW2 terminal and
the GND wire.
RECOMMENDATION: For inductive appliances that cause voltage spikes during
switching on/off, such as electrical motors, fans, vacuum cleaners and similar
ones, RC snubber (0.1 µF / 100 Ω / 1/2 W / 600 V AC) should be connected
parallel to the appliance.
CAUTION! Do not allow children to play with the push-buttons/ switches
connected to the Device. Keep the devices for remote control of Shelly Qubino
(mobile phones, tablets, PCs) away from children.
Z-WAVE® ADDING/REMOVING (INCLUSION/EXCLUSION) SmartStart adding
(inclusion):
SmartStart enabled products can be added into a Z-Wave® network by scanning
the Z-Wave® QR Code present on the Device with a gateway providing SmartStart
inclusion. No further action is required, and the SmartStart device will be
added automatically with-in 10 minutes of being switched on in the network
vicinity.
- With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway.
- Connect the Device to a power supply.
- Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
- Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave® network automatically.
- The blue LED will be blinking in Mode 2 during the adding process.
- The loads connected to O1 and O2 will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave® network.
- The green LED will be blinking in Mode 1 if the Device is success-fully added to a Z-Wave® network.
Adding (inclusion) with a switch/push-button:
- Connect the Device to a power supply.
- Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
- Enable add/remove mode on the gateway.
- Toggle the switch/push-button connected to the SW1 or SW2 terminal 3 times within 3 seconds (this procedure puts the Device in LEARN MODE*). The Device must receive on/off signal 3 times, which means pressing the push-button 3 times, or toggling the switch on and off 3 times.
- The blue LED will be blinking in Mode 2 during the adding process.
- The loads connected to O1 and O2 will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave® network.
- The green LED will be blinking in Mode 1 if the Device is success-fully added to a Z-Wave® network.
*LEARN MODE state allows the Device to receive network information from the gateway.
Adding (inclusion) with the S button:
- Connect the Device to a power supply.
- Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
- Enable add/remove mode on the gateway.
- To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
- Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE.
- The blue LED will be blinking in Mode 2 during the adding process.
- The loads connected to O1 and O2 will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave® network.
- The green LED will be blinking in Mode 1 if the Device is success-fully added to a Z-Wave® network.
Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.
- In case of Security 2 (S2) adding (inclusion), a dialog will appear asking you to enter the corresponding PIN Code (5 underlined digits) that are written on the DSK label on the side of the Device and on the DSK label inserted in the packaging.
IMPORTANT: The PIN Code must not be lost.
Removing (exclusion) with a switch/push-button:
- Connect the Device to a power supply.
- Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave® network.
- Enable add/remove mode on the gateway.
- Toggle the switch/push-button connected to the SW1 or SW2 terminal 3 times within 3 seconds (this procedure puts the Device in LEARN MODE*). The Device must receive on/off signal 3 times, which means pressing the push-button 3 times, or toggling the switch on and off 3 times.
- The blue LED will be blinking in Mode 2 during the removing process.
- The loads connected to O1 and O2 will be blinking 1s on/1s off/1s on/1s off if the Device is successfully removed from a Z-Wave® network.
- The blue LED will be blinking in Mode 1 if the Device is success-fully removed from a Z-Wave® network.
Removing (exclusion) with the S button:
- Connect the Device to a power supply.
- Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave® network.
- Enable add/remove mode on the gateway.
- To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
- Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE.
- The blue LED will be blinking in Mode 2 during the removing process.
- The loads connected to O1 and O2 will be blinking 1s on/1s off/1s on/1s off if the Device is successfully removed from a Z-Wave® network.
- The blue LED will be blinking in Mode 1 if the Device is success-fully removed from a Z-Wave® network.
Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.
FACTORY RESET
After Factory reset, all custom parameters and stored values (kWh, associations, routings, etc.) will return to their default state. HOME ID and NODE ID assigned to the Device will be deleted. Use this reset procedure only when the gateway is missing or otherwise inoperable.
Factory reset with a switch/push-button:
Note! Factory reset with the switch/push-button is only possible with-in
the first minute after the Device is connected to a power supply.
- Connect the Device to a power supply.
- Toggle the switch/push-button connected to the SW1 or SW2 terminal 5 times within 3 seconds. The Device must receive on/off signal 5 times, which means pressing the push-button 5 times, or toggling the switch on and off 5 times.
- During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
- The blue LED will be blinking in Mode 1 if the Factory reset is successful.
Factory reset with the S button:
Note! Factory reset with the S button is possible anytime.
- To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue.
- Press the S button multiple times until the LED turns Solid red.
- Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset.
- During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s.
- The blue LED will be blinking in Mode 1 if the Factory reset is successful.
NOTE: For more information about this Device refer to the Extended User Guide available at: https://kb.shelly.cloud/
LED SIGNALIZATION
LED blinking modes
Mode 1| 0,5s On/2s Off
Mode 2| 0,5s On/0,5s Off
Mode 3| 0,1s On/0,1s Off
Mode 4| (1x to 6x – 0,2s On/0,2s Off) + 2s Off
Mode 5| 0,2s On blue/0,2s On red
Normal mode| Colour| LED mode
---|---|---
Removed/Excluded| Blue| Mode 1
Added/Included| Green| Mode 1
Setting mode (with S button)| |
Adding/Removing (Inclusion/Exclusion) menu selected| Blue| Solid
Adding/Removing (Inclusion/Exclusion) menu – while pressing S button –
Adding/Removing (Inclusion/Exclusion) process selected| Blue| Mode 3
Factory reset menu selected| Red| Solid
Factory reset – while pressing S button – Factory reset process selected| Red|
Mode 3
“Setting in progress” mode| |
Factory reset and reboot| Blue / Red / Green|
Adding/Removing (Inclusion/Exclusion)| Blue| Mode 2
Checking power supply 230 V AC frequency or 24 V DC voltage| Blu e/ Red| Mode
5
OTA firmware updating| Blu e/ Red| Mode 2
Alarm mode**| |
Overcurrent detected O (O1 + O2)| Red| Mode 4 (1x)
Overheat detected| Red| Mode 4 (2x)
Power supply fault (power supply 230 V AC frequency or 24 V DC voltage fault)|
Red| Mode 4 (3x)
Overcurrent detected O1| Red| Mode 4 (4x)
Overcurrent detected O2| Red| Mode 4 (5x)
** LED will turn solid green for about 1s, then the blue and red LED will
start blinking in Mode 3 for approx. 2s.
LED will turn off 30 minutes after the power cycle. Every time you press on
the S button, the LED will turn on for 30 minutes. If alarm is active, LED
will not turn off.
OPERATIONAL INSTRUCTIONS
If the SW1 and SW2 are configured as a switch (default), each toggle of the
switch will change the outputs O1 and O2 states to the opposite states – on,
off, on, etc.
If the SW1 and SW2 are configured as a push-button in the Device settings,
each press of the push-button will change the outputs O1 and O2 states to
opposite states – on, off, on, etc.
SUPPORTED LOAD TYPES
- Resistive (incandescent bulbs, heating devices)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
SPECIFICATIONS
Power supply | 110-240 V AC / 24 V DC +/- 10% |
---|---|
Power consumption | < 0.3 W |
Power measurement (W) | Yes |
Max. switching voltage AC | 240 V |
Max. switching current AC | 10 A per channel, 16 A total, 18 A total peak |
Max. switching voltage DC | 30 V |
Max. switching current DC | 10 A |
Overheating protection | Yes |
Overcurrent protection | Yes |
Distance | Up to 40 m indoors (131 ft.) (depends on local condition) |
Z-Wave® repeater | Yes |
CPU | Z-Wave® S800 |
Z-Wave® frequency bands | 868,4 MHz; 865,2 MHz; 869,0 MHz; 921,4 MHz; 908,4 |
MHz; 916 MHz; 919,8 MHz; 922,5 MHz; 919,7-921,7-923,7 MHz; 868,1 MHz; 920,9
MHz
Maximum radio frequency power transmitted in frequency band(s)| < 25 mW
Size (H x W x D)| 37x42x16 ±0.5 mm / 1.46×1.65×0.63 ±0.02 in
Weight| 29 g / 1.02 oz..
Mounting| Wall console
---|---
Screw terminals max. torque| 0.4 Nm / 3.5 lbin
Conductor cross section| 0.5 to 1.5 mm² / 20 to 16 AWG
Conductor stripped length| 5 to 6 mm / 0.20 to 0.24 in
Shell material| Plastic
Color| Black
Ambient temperature| -20°C to 40°C / -5°F to 105°F
Humidity| 30% to 70% RH
Max. altitude| 2000 m / 6562 ft.
IMPORTANT DISCLAIMER
Z-Wave® wireless communication may not always be 100% reliable. This Device
should not be used in situations in which life and/or valuables are solely
dependent on its functioning. If the Device is not recognized by your gateway
or appears incorrectly, you may need to change the Device type manually and
ensure that your gateway supports Z-Wave Plus® multi-level devices.
ORDERING CODE: QNSW-002P16XX
XX – Values define product version per region.
DECLARATION OF CONFORMITY
Hereby, Shelly Europe Ltd. (former Allterco Robotics EOOD) declares that the
radio equipment type Wave 2PM is in compliance with Directive 2014/53/ EU,
2014/35/EU, 2014/30/EU, 2011/65/EU. The full text of the EU declaration of
conformity is available at the following internet address:
https://shelly.link/Wave2PM-DoC
MANUFACTURER:
Shelly Europe Ltd.
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: zwave-shelly@shelly.cloud
Support: https://support.shelly.cloud/
Web: https://www.shelly.com
Changes in the contact data are published by the Manufacturer at the official
website: https://www.shelly.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>