Martin JEM AF-1 12 Inch Effect Fan With Variable Speed And Remote Control User Manual
- June 13, 2024
- Martin
Table of Contents
JEM™ AF-1 MKII™
JEM™ AF-2™
USER MANUAL
DIMENSIONS
All dimensions are in millimeters
Connections panels
a– Remote in
b– DMX out (5-pin XLR)
c– DMX in (5-pin XLR)
d– DMX out (3-pin XLR)
e– DMX in (3-pin XLR)
f– DIP switch
g– Data LED
h– Power inlet
i– Fuse holder (EU model only)
AF-2™
EU model
a– Remote in
b– Power inlet
c– Main fuseholder
d– DMX out (5-pin XLR)
e– DMX in (5-pin XLR)
f– DMX out (3-pin XLR)
g– DMX in (3-pin XLR)
h– DIP switch
i– Data LED
US model
a– Remote in
b– Power inlet
c– DMX out (5-pin XLR)
d– DMX in (5-pin XLR)
e– DMX out (3-pin XLR)
f– DMX in (3-pin XLR)
g– DIP switch
h– Data LED
INTRODUCTION
Thank you for selecting a Jem AF series fan.
The AF-1 MkII™ and AF-2™ fans are powerful machines designed for professional
and semi-professional use in clubs, TV studios, theaters and touring contexts.
They are suitable for a wide range of applications including smoke and haze
dispersal, sending smoke through ducting, wind effects and cooling performers
or equipment. When fans are used at high output in conjunction with a smoke
machine at low output, a perfect haze effect can be produced.
Both fans have high quality sealed motors designed to withstand the high
condensation levels associated with close proximity smoke AF-1 MkII™ and AF-2™
fans can be controlled using the remote control unit supplied with each
product or via DMX on a serial data link. They may be interfaced with all
Martin and Jem smoke machines to allow simultaneous smoke and fan operation.
When used in combination with smoke machines, etc., DMX control allows
atmospheric effects to be integrated in the light show directly from the
lighting console. The remote control allows variable fan speed in continuous
or timer operation. When using the built-in timer, operating periods and
intervals between operating periods can be set independently.
AF-1 MkII™ and AF-2™ fans can be installed at any angle.
The most recent version of this manual is available under Smoke in the Support
area of the Martin website at: http://www.martin.com
Features
- DMX control.
- Remote control unit with instant or timer-controlled operation.
- Variable fan speed.
- Adjustable flying bracket with installation at any angle
- Can be flown or placed on a flat surface
- Rugged construction.
- Sealed high-quality maintenance-free fan motor offers high airflow, high resistance to condensation, ingress of dirt, smoke fluid, etc. and low noise.
Safety information
Warning! This product is not for household use. It presents risks of
lethal or severe injury due to electric shock, falls and fast-moving blades.
To reduce the risk of fire or electric shock, do not use this fan with any
solid-state speed control device.
Read
this manual before powering or installing the fan, follow the safety
precautions listed below and observe all warnings in this manual and printed
on the machine. Save this manual for future reference. If you have questions
about how to operate the system safely, please contact your Martin supplier or
call the Martin 24-hour service hotline on +45 8740 0000, or in the USA on
1-888-tech-180.
Refer any service operation not described in this manual to a qualified
technician.
Preventing electric shocks
- Always ground (earth) the machine electrically.
- Use only a source of AC power that complies with local building and electrical codes, and that has both overload and ground-fault protection.
- Check the AC supply voltage is correct for use with the machine. The voltage setting is printed on the machine’s serial label.
- Disconnect the machine from power before removing any components or servicing, and when not in use.
- Moisture can cause dangerous electrical faults. Do not aim fog output at electrical connections or devices.
- Do not expose this machine to wet conditions – the machine is not waterproof.
- Do not spill fluid over the machine. If fluid is spilled, disconnect the machine from power and clean with a damp cloth. If fluid is spilled onto electronic parts, contact an approved Martin™ dealer for advice.
- Do not dismantle or attempt to repair a faulty machine. Refer all service to an authorized Martin™ service dealer.
- Do not operate the machine if the power cable or connector is damaged. A damaged cable or connector must be replaced with a new item, available from your Martin™ dealer.
- Do not operate the machine with damaged, deformed or missing parts.
Preventing burns and fire
- Ensure that airflow around the machine is free and unobstructed.
- Do not operate the machine if the ambient temperature (Ta) exceeds 55°C (131° F).
Preventing injuries
- Never allow any object or part of your body to enter the path of the fan blades, and ensure that clothing, cables or other items cannot be sucked into the fan. Position the fan well out of reach of members of the public.
- Disconnect the fan from power before removing any cover or grill. Do not operate the fan unless all covers and grills are installed and securely fastened.
- Ensure that the supporting structure or surface can hold at least 10 times the weight of all installed devices.
- Use an approved means of secondary attachment such as a safety cable.
- Work from a stable platform and block access below the work area when installing, servicing or removing the machine.
Unpacking
AF-1 MkII™ and AF-2™ fans are supplied with:
- Remote control unit with cable
- Power cable
- User manual
- Adjustable flying bracket
INSTALLATION
This product must be installed by qualified personnel only.
AC power
AF-1 MkII™ and AF-2™ fans are available in two models:
- US model: 115 V, 50/60 Hz (for use with 100-120 VAC, 60 Hz power supplies) with integral power cord
- EU model: 230 V, 50/60 Hz (for use with 220-240 VAC, 50 Hz power supplies) with separate power cable connected via an IEC socket
The product’s voltage range is indicated on its serial number label. Do not operate the product at any other voltage.
Warning! For protection from fire and electric shock, AF-1 MkII™ and
AF-2™ fans must be grounded (earthed). The power supply must have overload and
ground-fault protection.
Check that power cables are undamaged and rated for the current requirements
of all connected devices before use.
Installing a mains plug on the power cable
On EU (230 V, 50/60 Hz) models, the power cable must be fitted with an earthed
mains plug (grounding-type cord cap) that fits your power distribution system.
Consult a qualified electrician if you have any doubts about proper
installation.
Wire color (US)| Wire color (EU)| Pin| Symbol| Screw
(US)
---|---|---|---|---
Green| Green-yellow| Ground (earth)| | Green
White| Blue| Neutral| N| Silver
Black| Brown| Live| L| Yellow or brass
Table 1: Mains plug connections
Following the mains plug manufacturer’s instructions, connect the power cable’s green and yellow wire to ground (earth), blue wire to neutral and brown wire to live. Table 1 shows some pin identification schemes.
Physical installation
AF-1 MkII™ and AF-2™ fans may be suspended from a suitable support such as a
truss, placed on a horizontal surface or fastened to a surface using the
bracket provided. Both fans can be installed at any angle. The AF-2™ fan may
be installed in a touring frame available as an accessory and either suspended
from a suitable support such as a truss or placed on a horizontal surface
resting on the touring frame’s rubber feet.
Warning! The slight vibration of the fan may cause fasteners to loosen.
Check all fasteners regularly for tightness, especially when the machine is
newly installed.
Position AF-1 MkII™ and AF-2™ fans well out of reach of the public.
Suspending from a support
Warning! Block access below the work area and work from a stable platform
when installing, servicing or removing the machine.
Use a secure secondary attachment that can hold at least 10 times the weight
of the machine.
Rigging clamps, omega brackets and fasteners are available as accessories from your Martin™ dealer. Any quarter-turn fasteners used must be turned a full 90° clockwise to lock them (see illustration on right).
- Check that any structure used to support the machine can support at least 10 times the total weight of all installed fixtures, clamps, cables, auxiliary equipment, etc.
- Check that all rigging clamps and fasteners are undamaged and can support at least 10 times the machine’s weight.
• AF-1 MkII fan: Bolt a rigging clamp to the machine’s flying bracket using a grade 8.8 (minimum) M12 bolt and lock nut, or as recommended by the clamp manufacturer, through the 13 mm hole in the center of the mounting bracket.
• AF-2 fan: Two rigging options exist. Either:
a) Bolt two rigging clamps to two Martin standard omega brackets (P/N
- using grade 8.8 (minimum) M12 bolts and lock nuts, or as recommended
by the clamp manufacturer. Fasten the two omega brackets to the flying bracket
or touring frame. This option allows the fan to be flown in line with or at
90° to a truss. or:
b) Bolt one rigging clamp to one Martin 250-300 wide omega bracket (P/N 91602000). Fasten the wide omega bracket to the flying bracket or touring frame. This option allows the fan to be flown at any angle relative to the truss.
- Clamp the fan to a truss or similar support.
- Loop a safety wire that can hold at least 10 times the weight of the machine through/over the support and through the flying bracket or touring frame.
- Loosen the swivel locks and tilt the fan to the desired angle. Turn the swivel locks clockwise to tighten. Check that fan, hardware and safety attachment are secure before applying power.
Placing on a horizontal surface
If an AF-1 MkII or AF-2 fan is to be placed on a horizontal surface:
- Ensure that the surface is level, stable and capable of supporting at least ten times the weight of the machine.
- Secure the machine so that it cannot slide or fall, even if air pressure during full speed operation and vibration are present.
- Eliminate any risk of accidental contact.
INSTALLING CONTROL HARDWARE
The AF-1 MkII™ and AF-2™ can be operated either using the Jem multifunction remote control unit supplied with each machine, or via DMX using a DMX control device and serial data link.
Remote control installation
To connect the remote control unit:
- Power the fan off.
- Plug the XLR connector on the remote control cable into the REMOTE IN plug on the connections plate (see “Connections panels” on page 4).
- Reapply power.
The AF-2 touring frame available as an accessory includes a docking station for the remote control unit (see illustration below). The remote control can be fastened in place using the two thumbscrews provided, and the remote cable wrapped around the brackets.
DMX installation
Up to 32 devices can be controlled on one DMX data link. Devices must be
‘daisy-chained’ in one continuous line without branches. More devices can be
added and the link can be branched using an optically isolated
splitter/amplifier such as the Martin RS-485 Opto-Splitter (P/N 90758060).
DMX cable connection
A reliable DMX data connection requires suitable cable. Standard microphone
cable cannot transmit DMX data reliably over long runs. For best results, use
shielded cable with at least one twisted pair specifically designed for RS-485
applications. Your Martin dealer can supply suitable high quality cable in
various lengths.
AF-1 MkII™ and AF-2™ both connect to a serial DMX data link using either their
3-pin or their 5-pin XLR DMX In and Out connectors. DMX connectors are wired
with pin 1 to ground, pin 2 to signal – (cold), and pin 3 to signal + (hot).
This is the standard pin assignment for DMX devices.
To connect the DMX data link:
- Power all devices off.
- Connect a data cable from the controller’s DMX data output to the first device’s DMX input
- Connect the DMX output of this device to the DMX input of the next device.
- Continue connecting up to a total of 32 devices in one single line, output to input.
- Terminate the link by inserting a male termination plug (available from your Martin dealer: P/N 91613017) into the data output of the last device. A termination plug is simply an XLR connector with a 120 Ohm, 0.25 W resistor soldered across pins 2 and 3.
Specifying DMX control channels
AF-1 MkII™ and AF-2™ use a single DMX control channel to receive instructions
from the controller. This control channel is the DMX address.
To control machines individuall y, each must have its own unique DMX address.
To control identical machines as a group, they can all be given the same DMX
address. They will then receive the same instructions and should behave
identically. Setting up identical fixtures with the same DMX address can also
be a good tool for troubleshooting unexpected behavior.
The DMX address on AF-1 MkII™ and AF-2™ fans can be set to any channel from 1
to 511 using DIP-switch pins 1 – 9. To set the DMX address:
- Decide on an available DMX address for each machine.
- Look up the DIP-switch settings using the Martin Address Calculator at http://www.martin.dk/service/utilities/AddrCalc/index.asp, or look for the address in the DIP-switch settings table on page 14. For example, to set the DMX address to 101, you need to set DIP-switch pins 1, 3, 6 and 7 to ON, as shown in the illustration below:
- Power the controller and all devices off.
- For each device, set the DMX address by setting DIP-switch pins 1 through 9 to the ON (1) or OFF (0) position as listed in the table on the next page. As an example, channel 101 is highlighted in the table.
DMX address DIP-switch settings
To use Ta ble 2 , first find the DMX a ddress in the mai n blo ck i n th e ta
ble.
Then read the settings for pins 1 – 5 to the left and read the settings for
pins 6 – 9 above the address. “0” means OFF and “1” means ON.
For example, to set the DMX address to 101, you need to set DIP-switch pins 1, 3, 6 and 7 to ON, as highlighted in the table.
Table 2: DMX address DIP-switch settings
DIP-Switch 10 test function
DIP-switch 10 allows testing without a remote control or DMX signal. If you
switch it to the ON (1) position, the fan runs at full output for 2 seconds.
OPERATION
Before powering on, check that the fan is correctly and safely installed.
Using fans with smoke machines
When using a fan in combination with a smoke machine, fog machine or hazer,
place the fan behind the machine, as illustrated on the right. Do not place
the fan in front of the machine and direct the output from the machine into
the fan, as this will cause undesirable moisture and residue build-up. The fan
blades will also degrade the quality of the smoke.
Using fans with smoke ducting
For best results and easy directional control, connect fans to smoke ducting
using a Y-shaped arrangement, placing the fan on one arm of the Y and the
smoke machine on the other.
Remote control operation
AF-1 MkII™ remote control
AF-1 Multifunction remote overview
a LEVEL / TIMER control
b RUN / TIMER ENGAGE button
c TIMER OFF LED
d TIMER ON LED
e TIMER SET button
The AF-1 MkII™ remote offers the following control options:
- Continuous operation with fan speed adjustment
- Timer operation: timed fan bursts repeated at timed intervals
- “One shot” operation: single timed fan bursts that you trigger at will
Continuous operation
To set up continuous operation:
- Turn the LEVEL / TIMER control to OFF
- Press RUN / TIMER ENGAGE once for less than one second. The fan will run continuously until this button is pressed again.
- Once you have started continuous operation, adjust the fan speed level using the LEVEL / TIMER control.
The green LEVEL / TIMER LED lights in continuous operation.
Timer operation
The automatic timer sets the AF-1 MkII™ to produce timed fan bursts at regular
intervals. You need to set two times: the run/on time during which the fan
will run, and the wait/off time during which the fan will switch to idle. To
set up timer operation:
- Press TIMER SET. The ON LED will flash. You are now setting the On/Run time.
- Turn the LEVEL / TIMER control to the required “run” time, as shown on the scale (OFF – 255 seconds).
- Press TIMER SET once. The ON LED will light constantly and the OFF LED will flash. You are now setting the Off/Wait time.
- Turn the LEVEL / TIMER control to the required “wait” time (OFF – 255 seconds).
- Press TIMER SET once more. Both ON/OFF LEDs will light to show that the timer is programmed.
The run and wait times are now stored and will be remembered even after the
unit has been powered off.
To start the timer using the times you have set, press RUN / TIMER ENGAGE
briefly. To turn off the timer, press RUN / TIMER ENGAGE briefly again. When
the timer is engaged, the ON LED lights during the On/Run time and the OFF LED
lights during the Off/Wait time. Additional functions:
- If you only want to change the Off/Wait time, leaving the On/Run time unchanged, press TIMER SET twice. This will take you directly to setting the Off time without changing the On time.
- To find out what the current time settings are, press TIMER SET then rotate the LEVEL / TIMER control slowly until the “ON” LED begins to flash very rapidly. The control is now set to the current run/on time. Press TIMER SET once and rotate the control slowly again until the “OFF” LED begins to flash very rapidly. The control is now set to the current wait/off time. Press TIMER SET again to return to normal operation.
“One-shot” operation
“One shot” operation lets you run a fixed-time fan burst at will by pressing
the RUN button. To set up “one-shot” operation:
-
Press TIMER SET. The ON LED will flash. You are now setting the On/Run time.
-
Turn the LEVEL / TIMER control to the required “run” time as shown on the scale (OFF – 255 seconds).
-
Press TIMER SET once. The ON LED will light constantly and the OFF LED will flash.
-
Turn the LEVEL / TIMER control fully right to “OS” (“One Shot”).
AF-1 MKii™ and AF-2™ user manual -
Press TIMER SET once more.
The timer is now programmed to one-shot mode and this will be remembered even after the unit has been powered off.
To produce a timed fan burst, press RUN brie fly. To stop the timed burst early, press RUN briefly again.
AF-2™ remote control
A. INSTANT
FAN OPERATION BUTTON – Press to run the fan at the speed set on the fan speed
control.
B. STANDBY – Puts the fan into standby mode. Must be set to ON to operate in
any mode.
C. TIMER VALUE BUTTON – When timer is active, adjusts timer values by a factor
of 8 (i.e. a 5 second run time becomes 40 seconds and a 10 second delay time
becomes 1 minute 20 seconds).
D. TIMER ENGAGE – Engages the timer to run the fan according to the timer
settings.
E. SPEED – Sets fan speed from minimum to maximum.
F. POWER LED – Lights when power is on.
G. DELAY TIME CONTROL – Sets intervals between operating periods during timer-
controlled operation.
H. CYCLE LED – Lights during timer-controlled operation.
I. RUN TIME CONTROL – Sets duration of operating periods during timer-
controlled operation.
The multifunction remote control unit supplied with the AF-1 MkII™ and AF-2™
allows instant or timer-controlled fan operation and airflow control.
The unit also gives feedback on the status of the machine.
To set timer operation using the remote control:
- Set the desired amount of airflow using the SPEED control
- Set wait/off time intervals between operating periods by setting the DELAY control to between 1 and 9.
- Set duration of operating periods by setting the RUN control to between 1 and 9.
- Set the STANDBY button to ON
- Set the TIMER ON button to ON.
The CYCLE LED lights when the timer function is active.
To extend timer settings, p re ss the X8 button. This will multiple loath RUN and DELAY times by 8.
DMX control
Fan speed on the AF-1 MkII™ and AF-2™ can be controlled using a DMX
controller.
DMX controller operation
When a fan is powered on, the Data LED next to the DIP-switch will light when
a valid DMX signal is received.
Increase the value on the machine’s DMX control channel to increase fan speed
as shown below:
DMX control channel levels
Level | Percentage | Effect |
---|---|---|
0-27 | 0-10% | Fan speed zero. |
28-255 | 11-100% | 1 – 100% fan speed. |
SERVICE AND MAINTENANCE
Any service procedure not described here should be referred to a qualified
technician.
Warning! Disconnect the fan from power before removing any grills or
covers.
Cleaning
Clean the outside of the fan with a damp cloth only. Do not use solvents.
Periodic cleaning of the fan blades and grills is necessary to maintain peak
performance. Cleaning intervals will depend on the operating environment.
Inspect the fan regularly for dust and smoke residue buildup, and clean as
soon as there is significant dirt buildup on fan blades or at the first signs
that airflow through grills may be restricted.
Use a soft brush and vacuum to clean grills and fan blades.
AF-1 MKii cleaning access
- Disconnect the fan from power.
- Remove the four cross-head screws (arrowed) from the grill and lift the grill/motor assembly clear of the housing. The motor cable will remain attached to the motor and the housing. Avoid straining the cable.
- After cleaning, replace the grill and screws, ensuring that screws are securely tightened.
AF-2 cleaning access
-
Disconnect the fan from power.
-
Remove the 16 cross-head screws from the covers (see illustration above), and remove the covers.
-
Reaching into the fan housing for access to the locking nuts, remove the four 6mm Allen screws holding the front grill (see illustration on right), collecting all washers and grommets for reuse.
Note: the front grill is on the opposite side from the fan motor. It should be possible to clean the machine without removing the rear grill that holds the fan motor. -
After cleaning, replace the screws and front grill. Reassemble exactly as shown in the next illustration, making sure that the rubber
grommets (A) are seated in the fan housing (B). If this assembly sequence is not respected, the AF-2 will be excessively noisy.
Replacing the main fuse (EU models)
EU models have a main fuse that can be changed by the user.
On US models the main fuse is internal. If you suspect that the main fuse has
blown, please contact your Martin™/Jem dealer for assistance.
An indication that the main fuse may have blown is that, when power is
applied:
- the Data LED does not light when a DMX signal is present, or
- the ON LED (AF-1 MkII™) or Power LED on the remote (AF-2™) does not light when a remote control is connected.
The main fuse can be replaced by the user if necessary. Never bypass the fuse
or replace it with one of another size or rating.
To replace the ma in fuse:
- Disconnect the power cable from the fan.
- Use a screwdriver to lever the fuse holder out of the power inlet socket (see illustration).
- Replace the fuse with one of the same rating and type. Fuse details are given on the serial number label and in the Specifications sections of this manual.
- Replace the fuse holder and reconnect to power.
If the fuse blows repeatedly, disconnect the machine from power and from control equipment and contact your Martin/Jem dealer for service.
TROUBLESHOOTING
Problem | Probable cause(s) | Suggested remedy |
---|
No light from status
LEDs on remote control or fan| No power| Check power supply and connections
Remote control not set to Standby (AF-2TM only)| Press Standby button
Remote control not connected| Check connections
RUN / TIMER button not pressed (AF-1 Mkt! Tm only)| Press button.
Fuse blown| Replace fuse with one of same type and rating.
If fuse blows repeatedly, consult your Martin TM dealer.
Power is applied, but no fan action using DMX| Incorrect DMX address settings|
Check DIP-switch
No DMX termination| Fit termination plug to last device on DMX link
Excessively noisy operation| Grill loose| Check and tighten grill retaining
screws
AF-2: Incorrectly assembled grill mounting hardware| Check, and if necessary
reassemble (see “AF-2 cleaning access” on page 23)
Reduced airflow dirty| Grills and/or fan blades| Check and clean
Low supply voltage| Check AC supply
AF-1 MKII™ SPECIFICATIONS
Physical (flying bracket installed)
Width. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 380 mm (15.0 in.)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . 410.5 mm (16.2 in.)
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 180 mm (7.1 in.)
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 8.5 kg (18.7 lbs.)
Construction
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . Steel
Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . Black
Performance
Fan speed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
200 – 2500 rpm approx.
Max. airflow. . . . . . . . . . . . . . . . . . . . . . . . 1815 m³ per hour
(64 cu.ft. Per hour)
Operation time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . Continuous
Noise level (max.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 70 dBA
Control and programming
Control options . . . . . . . . . . . .Remote control unit (supplied), DMX,
test switch
Remote control functions . . . . . . . . . . . . . . . .Instant or timer-
controlled output,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-100% output level
adjustment
Delay time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 2 – 255 seconds
Run time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 2 – 255 seconds
Max. length of remote cable . . . . . . . . . . . . . . . 50 metres (3 metres
supplied)
DMX channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . 1
DMX addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . DIP-switch
DMX compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. USITT DMX-512A
Installation
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . Any
Minimum clearance around machine . . . . . . . . . . . . . . . . . . . . . . .
0.1 m (4 in.)
Connections
Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 3-pin locking XLR
DMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-pin and 5-pin locking XLR
AC power . . . . . . IEC power inlet (EU model), integral power cord (US
model)
Electrical
US model
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110-120
V nominal, 50/60 Hz
Main fuse (not user-changeable) . . . . . . . . . . . . . . . . . . . . . . .
5 AT (slow blow)
EU model
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220-240
V nominal, 50/60 Hz
Main fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 3.15 AT (slow blow)
Typical Power and Current
US model at 115 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 175 W, 1.48 A
EU model at 230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . 120 W, 0.53 A
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Thermal
Minimum ambient temperature (Ta min.) . . . . . . . . . . . . . . . . . . . .
.0° C (32° F)
Maximum ambient temperature (Ta max.) . . . . . . . . . . . . . . . . . .55° C
(131° F)
Approvals
EU Safety . . . . . . . . . . . . . . . . . . . . . . EN 60 335-1
EU EMC . . . . . . . . . . . . EN 50 081-1, EN 50 082-1
US Safety . . . . . . . . . . . . . . . . . . . . . . . . . . UL 507
Canadian Safety . . . . . . . . . . . . . . . . . . CSA C22.2
Australia/NZ (pending) ………………………………RCM
United Kingdom ………………………………………UKCA
Included items
Analog remote control with 3 m (9.8 ft) cable. . . . . . . . . . . . . . .
.P/N 92765022
Adjustable flying bracket
User manual
US model
3 m (9.8 ft) integral power cable 18AWG
with US cord cap (UL approved) . . . . . . . . . . . . . . . . . . . . . .
.P/N 11501502
EU model
1.5 m (4.9 ft) IEC power cable 3 x 1.0mm² without mains plug . . P/N 11501012
Accessories
G-clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .P/N 91602003
Half-coupler clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .P/N 91602005
DMX termination plug (end of link), XLR male . . . . . . . . . . . . . .P/N
91613017
Ordering information
Jem AF-1 MKii™ DMX Fan, US model, 115 V, 50/60 Hz . . . . . . . P/N 92615110
Jem AF-1 MKii™ DMX Fan, EU model, 230 V, 50/60 Hz. . . . . . .P/N 92615010
Physical
Dimensions (L x W x H) . . . . . . . . . . . . . . . . . . . . . . . . . .
.600 x 310 x 600 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . (23.7 x 12.2 x 23.7 in.)
Dimensions, flying bracket installed (L x W X H) . . . . . . . .700 x 310 x
680 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . (27.6 x 12.2 x 26.8 in.)
Dimensions, touring frame installed (L x W x H) . . . . . . . .750 x 335 x 770
mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . (29.6 x 13.2 x 30.4 in.)
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 15.7 kg (34.7 lb.)
Weight including flying bracket . . . . . . . . . . . . . . . . . . . . . . .
. 17.5 kg (38.6 lb.)
Weight including touring frame . . . . . . . . . . . . . . . . . . . . . . . .
21.4 kg (47.2 lb.)
Construction
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . Aluminum
Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . Black
Performance
Fan speed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 0 – 1400 rpm @ 50 Hz
Max. airflow. . . . . . . . . . . . . . . . . . . . . . .5700 m³
per hour (200 cu.ft. per hour)
Operation time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . Continuous
Noise level (max.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 73 dBA
Control and programming
Control options . . . . . . . . . . . .Remote control unit (supplied), DMX,
test switch
Remote control functions . . . . . . . . . . . . . . . .Instant or timer-
controlled output,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-100%
output level adjustment
Delay time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 2 – 20 seconds
Run time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 2 – 20 seconds
Max. length of remote cable . . . . . . . . . . . . . . . 50 metres (5 metres
supplied)
DMX channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . 1
DMX addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . DIP-switch
DMX compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. USITT DMX-512-A
Installation
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . any
Minimum clearance around machine . . . . . . . . . . . . . . . . . . . . . . .
0.1 m (4 in.)
Connections
Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 3-pin locking XLR
DMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-pin and 5-pin locking XLR
AC power . . . . . . IEC power inlet (EU model), integral power cord (US
model)
Electrical
US model
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110-120
V nominal, 50/60 Hz
Main fuse (not user-changeable) . . . . . . . . . . . . . . . . . . . . . 6.3
AT (slow blow)
EU model
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220-240
V nominal, 50/60 Hz
Main fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 5 AT (slow blow)
Typical power and current
US model at 115 V, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 350 W, 3.3 A
EU model at 230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . 245 W, 1.2 A
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Thermal
Minimum ambient temperature (Ta min.) . . . . . . . . . . . . . . . . . . . .
.0° C (32° F)
Maximum ambient temperature (Ta max.) . . . . . . . . . . . . . . . . . .55° C
(131° F)
Approvals
EU Safety . . . . . . . . . . . . . . . . . . . . . . EN 60 335-1
EU EMC . . . . . . . . . . . . EN 50 081-1, EN 50 082-1
US Safety . . . . . . . . . . . . . . . . . . . . . . . . . . UL 507
Canadian Safety . . . . . . . . . . . . . . . . . . CSA C22.2
Australia/NZ (pending) . . . . . . . . . . . . . . . . . . RCM
United Kingdom ……………………………………….UKCA
Included items
Jem multifunction remote control with 5 m (16.4 ft) cable and XLR connector
Adjustable flying bracket
User manual
US model
3 m (9.8 ft) integral power cable 18AWG
with US cord cap (UL approved) . . . . . . . . . . . . . . . . . . . . . .
.P/N 11501502
EU model
1.5 m (4.9 ft) IEC power cable 3 x 1.0mm²
without mains plug . . P/N 11501012
Accessories
To uringframe , AF – 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . P / N 92620006
Wide omega bracket 250-300 with 4 x quarter-turn fasteners . . .P/N 91602000
Standard omega bracket with 2 x quarter-turn fasteners . . . . . . .P/N
91602001
G-clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .P/N 91602003
Half-coupler clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .P/N 91602005
DMX termination plug (end of link), XLR male . . . . . . . . . . . . . .P/N
91613017
Ordering information
Jem AF-2™ DMX Fan, US model, 115 V, 50/60 Hz . . . . . . . . . .P/N 92615400
Jem AF-2™ DMX Fan, EU model, 230 V, 50/60 Hz . . . . . . . . . .P/N 92615300
Specifications subject to change without notice. For latest specifications and
product information see www.martin.com
Disposing of this product
**** Martin products are supplied in compliance with Directive 2012/19/EC of
the European Parliament and of the Council of the European Union on WEEE
(Waste Electrical and Electronic Equipment), where applicable.
Help preserve the environment! Ensure that this product is recycled at the end
of its life. Your supplier can give details of local arrangements for the
disposal of Martin products