Shelly Qubino QMSW-0A1P8EU Wave 1PM Mini User Guide
- June 17, 2024
- Shelly Qubino
Table of Contents
Shelly Qubino QMSW-0A1P8EU Wave 1 PM Mini
LEGEND
Device terminals
- N : Neutral terminal
- L : Live terminal (110–240 V AC)
- SW (SW1): Switch/push-button input terminal (controlling O (O1))
- O (O1): Load circuit output terminal (1)
Wires:
- N : Neutral wire
- L : Live wire (110-240 V AC)
Button
S : S button (Fig. 2) USER AND SAFETY GUIDE
Z-Wave® smart switch with power measurement
READ BEFORE USE
This document contains important technical and safety information about the Device, its safe use and installation.
- ⚠CAUTION! Before beginning the installation, please read carefully and entirely this guide and any other documents accompanying the Device. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee (if any). Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this device due to failure to follow the user and safety instructions in this guide.
TERMINOLOGY
Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller,
Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is
a device that serves as a central hub for a Z-Wave® smart home network. The
term “gateway” is used in this document.
S button – The Z-Wave® Service button, which is located on Z-Wave®
devices and is used for various functions such as inclusion (adding),
exclusion (removing), and resetting the device to its factory default
settings. The term “S button” is used in this document.
Device – In this document, the term “Device” is used to refer to the
Shelly Qubino device that is a subject of this guide.
ABOUT SHELLY QUBINO
Shelly Qubino is a line of innovative microprocessor-managed devices, which allow remote control of electric circuits with a smartphone, tablet, PC, or home automation system. They work on Z-Wave® wireless communication protocol, using a gateway, which is required for the configuration of devices. When the gateway is connected to the internet, you can control Shelly Qubino devices remotely from anywhere. Shelly Qubino devices can be operated in any Z-Wave® network with other Z-Wave® certified devices from other manufacturers. All mains-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. Devices are designed to work with older generations of Z-Wave® devices and gateways.
ABOUT THE DEVICE
The Device is a small form factor smart switch with power measurement. It controls the on/off function for one electrical appliance with a load of up to 8 A AC, such as a bulb, ceiling fan, or IR heater. It is compatible with switches (default) and push buttons.
INSTALLATION INSTRUCTIONS
The Device can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.
For the installation instructions, refer to the wiring scheme (Fig. 1) in this user guide.
- ⚠CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
- ⚠CAUTION! Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
- ⚠CAUTION! Do not open the Device. It does not contain any parts that can be maintained by the user. For safety and licensing reasons, unauthorized change and/or modification of the Device is not permitted.
- ⚠CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
- ⚠CAUTION! No SELV/PELV circuits may be connected to the terminals of the inputs and outputs, including the extension inputs.
- ⚠CAUTION! Do not connect the Device to appliances exceeding the given max. load!
- ⚠CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
- ⚠CAUTION! Do not install the Device where it can get wet.
- ⚠CAUTION! Do not use the Device if it has been damaged!
- ⚠CAUTION! Do not attempt to service or repair the Device yourself!
- ⚠CAUTION! Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a mains voltage tester or multimeter. When you are sure that there is no voltage, you can proceed to connecting the wires.
- ⚠CAUTION! Do not shorten the antenna.
- ⚠RECOMMENDATION : Place the antenna as far away as possible from metal elements as they can cause signal interference.
- ⚠CAUTION! The load current circuit has to be secured by a cable protection switch in accordance with EN60898-1 (tripping characteristic B or C, max. 8 A rated current, min. 6 kA interrupting rating, energy limiting class 3).
- ⚠RECOMMENDATION: Connect the Device using solid single-core cables or stranded cables with ferrules. The cables should have insulation with increased heat resistance, not less than PVC T105°C (221°F).
- ⚠RECOMMENDATION: For inductive appliances that cause voltage spikes during switching on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 μF / 100 Ω / 1/2 W / 600 V AC) should be connected parallel to the appliance.
- ⚠CAUTION! Do not allow children to play with the push buttons/switches connected to the Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.
EXTENDED USER GUIDE
For more detailed installation instructions, use cases, and comprehensive guidance on adding/removing the Device to/from a Z-Wave® network, factory reset, LED signalization, Z-Wave® command classes, parameters, and much more, refer to the extended user guide at:
SPECIFICATIONS
OPERATIONAL INSTRUCTIONS
If the SW (SW1) is configured as a switch (default), each toggle of the switch
will change the output O (O1) state to the opposite state – on, off, on, etc.
If the SW (SW1) is configured as a push-button in the Device settings, each
press of the push-button will change the output O (O1) state to the opposite
state – on, off, on, etc.
SUPPORTED LOAD TYPES
Resistive (incandescent bulbs, heating devices) Capacitive (capacitor banks,
electronic equipment, motor start capacitors) Inductive with RC Snubber (LED
light drivers, transformers, fans, refrigerators, air-conditioners)
IMPORTANT DISCLAIMER
Z-Wave® wireless communication may not always be 100% reliable. This Device
should not be used in situations in which life and/or valuables are solely
dependent on its functioning. If the Device is not recognized by your gateway
or appears incorrectly, you may need to change the Device type manually and
ensure that your gateway supports Z-Wave Plus® multi-channel devices.
ORDERING CODE: QMSW-0A1P8XX
XX – Values define product version per region.
DECLARATION OF CONFORMITY
Hereby, Shelly Europe Ltd. declares that the radio equipment type Wave 1PM
Mini is in compliance with Directive 2014/53/ EU, 2014/35/EU, 2014/30/EU,
2011/65/EU. The full text of the EU declaration of Conformity is available at
the following internet address:
https://shelly.link/Wave1PMMini-DoC
MANUFACTURER
Shelly Europe Ltd.
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: zwave-shelly@shelly.cloud
Support : https://support.shelly.cloud/
Web : https://www.shelly.com
Changes in the contact data are published by the Manufacturer at the official
website.