Shelly Qubino Z-Wave Smart Power Meter User Guide
- June 1, 2024
- Shelly Qubino
Table of Contents
Shelly Qubino Z-Wave Smart Power Meter
Product Information
Specifications
-
Power supply: 110-240 V AC, 50/60 Hz
-
Power consumption: < 0.3 W
-
Power measurement (W): Yes
-
External protection: 10 A, tripping characteristic B or C 6 kA interrupting rating Energy limiting class 3
-
Max. measurement power: 3840 W
-
Max. measurement current: 16 A
-
Overheating protection: Yes
-
Distance: Up to 40 m indoors (131 ft.) (depends on local condition)
-
CPU: 908.4 MHz
-
Maximum radio frequency power transmitted in frequency
band(s): < 25 mW -
Size (H x W x D):
- Weight
- Mounting: Wall box
- Screw terminals max. torque: 0.4 Nm / 3.54 lbin
- Conductor cross section
- Conductor stripped length: 5 to 6 mm / 0.20 to 0.24 in
- Shell material: Plastic
- Color: Light grey
-
Ambient temperature:
- Humidity: 30% to 70% RH
- Max. altitude: 2000 m / 6562 ft.
-
SUPPORTED LOAD TYPES:
- Resistive (incandescent bulbs, heating devices)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
Product Usage Instructions
Installation Instructions
The Device can be retrofitted into standard electrical wall boxes, behind
power sockets and light switches or other places with limited space.
- Connect the loads to the O terminals of the Device and the Neutral wire as shown in Fig. 1.
- Connect the Live wire to an L terminal of the Device.
- Connect the Neutral wire to an N terminal of the Device.
Extended User Guide
For more detailed installation instructions, use cases, and comprehensive
guidance on adding/removing the Device, refer to the extended user guide at:
https://shelly.link/WavePMMini-KB-US
FAQ
-
What is the maximum power consumption supported by the Wave PM Mini?
The Wave PM Mini supports a maximum power consumption of 3840 W at 240 V AC. -
Where can I find disposal and recycling information for the product?
Information regarding disposal and recycling can be found in the Important Disclaimer section of the user manual.
LEGEND
Device terminals:
- N: Neutral terminal
- L: Live terminal (110–240 V AC)
- O (O1): Load circuit output terminals (bridged internally) Wires:
- N: Neutral wire
- L: Live wire (110-240 V AC)
Button:
- S: S button (Fig.2)
USER AND SAFETY GUIDE
Z-Wave® smart power meter
READ BEFORE USE
This document contains important technical and safety information about the
Device, its safe use and installation.
CAUTION! Before beginning the installation, please read carefully and
entirely this guide and any other documents accompanying the Device. Failure
to follow the installation procedures could lead to malfunction, danger to
your health and life, violation of law or refusal of legal and/or commercial
guarantee (if any). Shelly Europe Ltd. is not responsible for any loss or
damage in case of incorrect installation or improper operation of this device
due to failure of following the user and safety instructions in this guide.
TERMINOLOGY
Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave®
main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device
that serves as a central hub for a Z-Wave® smart home network. The term
“gateway” is used in this document.
S button – The Z-Wave® Service button, which is located on Z-Wave® devices and
is used for various functions such as inclusion (adding), exclusion
(removing), and resetting the device to its factory default settings. The term
“S button” is used in this document.
Device – In this document, the term “Device” is used to refer to the Shelly
Qubino device that is a subject of this guide.
ABOUT SHELLY QUBINO
Shelly Qubino is a line of innovative microprocessor-managed devices, which
allow remote control of electric circuits with a smartphone, tablet, PC, or
home automation system. They work on Z-Wave® wireless communication protocol,
using a gateway, which is required for the configuration of devices. When the
gateway is connected to the internet, you can control Shelly Qubino devices
remotely from anywhere. Shelly Qubino devices can be operated in any Z-Wave®
network with other Z-Wave® certified devices from other manufacturers. All
mains operated nodes within the network will act as repeaters regardless of
vendor to increase reliability of the network. Devices are designed to work
with older generations of Z-Wave® devices and gateways.
ABOUT THE DEVICE
The Device is a small form factor smart power meter, which allows remote
monitoring of electric appliances power consumption with a load of up to 16 A.
INSTALLATION INSTRUCTIONS
The Device can be retrofitted into standard electrical wall boxes, behind
power sockets and light switches or other places with limited space.
For the installation instructions, refer to the wiring schemes (Fig. 1) in
this user guide.
WARNING! Risk of electric shock. Make sure that after installing the
device, its screw terminals are not accessible to users and protected by
accidental short circuits!
- The operation of the service button must be managed by a professional installer. Risk of electric shock.
CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
- Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
- Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
- Do not open the Device. It does not contain any parts that can be maintained by the user. For safety and licensing reasons, unauthorized change and/or modification of the Device is not permitted.
- The load current circuit must be secured by a cable protection switch in accordance with EN60898-1 (tripping characteristic B or C, max. 10 A rated current, min. 6 kA interrupting rating, energy limiting class 3).
- No SELV/PELV circuits may be connected to the terminals of the inputs and outputs, including the extension inputs.
- Do not connect the Device to appliances exceeding the given max. load!
- Do not shorten the antenna.
RECOMMENDATION: Place the antenna as far away as possible from metal
elements as they can cause signal interference.
CAUTION! Connect the Device only in the way shown in these instructions.
Any other method could cause damage and/or injury.
- Do not install the Device where it can get wet.
- Do not use the Device if it has been damaged!
- Do not attempt to service or repair the Device yourself!
- Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a mains voltage tester or multimeter. When you are sure that there is no voltage, you can proceed to connecting the wires.
- Do not allow children to play with the push-buttons/ switches connected to the Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.
RECOMMENDATION: Connect the Device using solid single-core cables or
stranded cables with ferrules. The cables should have insulation with
increased heat resistance, not less than PVC T105°C (221°F). away from
children.
RECOMMENDATION: For inductive appliances that cause voltage spikes during
switching on/off, such as electrical motors, fans, vacuum cleaners and similar
ones, RC snubber (0.1 µF / 100 Ω / 1/2 W / 600 VAC) should be connected
parallel to the appliance.
Connect the loads to the O terminals of the Device and the Neutral wire, as
shown on Fig. 1.
Connect the Live wire to an L terminal of the Device.
Connect the Neutral wire to a N terminal of the Device.
EXTENDED USER GUIDE
For more detailed installation instructions, use cases, and comprehensive
guidance on adding/removing the Device to/from a Z-Wave® network, factory
reset, LED signalization, Z-Wave® command classes, parameters, and much more,
refer to the extended user guide at: https://shelly.link/WavePMMini-KB-US
SPECIFICATIONS
Power supply | 110-240 V AC, 50/60 Hz |
---|---|
Power consumption | < 0.3 W |
Power measurement (W) | Yes |
External protection | 10 A, tripping characteristic B or C |
6 kA interrupting rating Energy limiting class 3
Max. measurement power| 3840 W
Max. measurement current| 16 A
Overheating protection| Yes
Distance| Up to 40 m indoors (131 ft.) (depends on local condition)
Z-Wave® repeater| Yes
CPU| Z-Wave® S800
Z-Wave® frequency bands| 908.4 MHz
Maximum radio frequency power transmitted in frequency band(s)| < 25 mW
Size (H x W x D)| 29x35x16 ±0.5 mm / 1.11×1.35×0.63 ±0.02 in
Weight| 13 ±1 g / 0.46 ±0.04 oz
Mounting| Wall box
Screw terminals max. torque| 0.4 Nm / 3.54 lbin
Conductor cross section| 0.5 to 1.5 mm² / 20 to 16 AWG
Conductor stripped length| 5 to 6 mm / 0.20 to 0.24 in
Shell material| Plastic
Color| Light grey
Ambient temperature| -20°C to 40°C / -5°F to 105°F
Humidity| 30% to 70% RH
Max. altitude| 2000 m / 6562 ft.
SUPPORTED LOAD TYPES
Resistive (incandescent bulbs, heating devices)
Inductive with RC Snubber (LED light drivers, transformers, fans,
refrigerators, air-conditioners)
Capacitive (capacitor banks, electronic equipment, motor start capacitors)
IMPORTANT DISCLAMER
Z-Wave® wireless communication may not always be 100%reliable. This Device
should not be used in situations in which life and/or valuables are solely
dependent on its functioning. If the Device is not recognized by your gateway
or appears incorrectly, you may need to change the Device type manually and
ensure that your gateway supports Z-Wave Plus®
multi-channel devices.
DISPOSAL & RECYCLING
This refers to the waste of electrical and electronic equipment. It is
applicable in the US and other countries to collect waste separately.
This symbol on the product or in the accompanying literature indicates that
the product should not be disposed of in the daily waste. Wave PM Mini US must
be recycled to avoid possible damage to the environment or human health from
uncontrolled waste disposal and to promote the reuse of materials and
resources. It is your responsibility to dispose of the device separately from
general household waste when it is already unusable.
FCC NOTES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modification or change to this equipment. Such modifications or change could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF exposure statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. The device has been evaluated to meet general RF
exposure requirement. The device can be used in portable exposure condition
without restriction.
ORDERING CODE: QMEM-0A1PC16US
MANUFACTURER
Shelly Europe Ltd.
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: zwave-shelly@shelly.cloud
Support: https://support.shelly.cloud/
Web: https://www.shelly.com
Changes in the contact data are published by the Manufacturer at the official
website.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>