MASTERCRAFT 1512SSW
Owner’s Manual
Shop genuine replacement parts for MASTERCRAFT
1512SSW
1512SSW Vacuum Cleaner
Find Your MASTERCRAFT Vacuum Cleaner Parts – Select From 99
Models
——– Manual continues below ——–
SAFETY, OPERATION & MAINTENANCE MANUAL
POLY & STEEL DRY & WET/DRY VACUUM CLEANERS
This unit is intended for commercial use.
READ AND FOLLOW ALL INSTRUCTIONS, WARNINGS & CAUTIONS BEFORE USING THIS VACUUM/BLOWER
READ ALL INSTRUCTIONS BEFORE OPERATING
This vacuum cleaner will afford you many years of trouble-free operating
satisfaction, provided it is given proper care. All parts have passed rigid
quality control standards prior to being assembled to produce the finished
product. Prior to packaging, the vacuum was again inspected for assurance of
flawless assembly.
Your vacuum is protectively packed to prevent damage in shipment. We recommend
that upon delivery, unpack the vacuum and inspect it for any possible damage.
Only a visual examination will reveal damage that may have occurred. If damage
is discovered, immediately notify the transportation company that delivered
your vacuum. As a shipper, we are unable to report claims for concealed
damage.
You must originate any claims within 5 days.
This manual is for your protection and information. PLEASE READ CAREFULLY
since failure to follow precautions could result in discomfort or injury.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
To Reduce the Risk of Fire, Electric Shock or Injury:
Dry Vacuums
Electric shock could occur if used on wet surfaces.
DO NOT expose to rain – Store Indoors
Wet Vacuums
To avoid electric shock DO NOT expose to rain. Store Indoors Electric shock
could occur if power nozzle is used on wet surfaces.
When using this electric vacuum, basic precautions should always be followed, including the following:
- DO NOT leave the vacuum when plugged in. Unplug it from the outlet when not in use and before servicing.
- This is NOT a toy. Close attention is necessary when used around or near children.
- Use only as described in this safety manual. Use only the manufacturer’s recommended attachments and accessories.
- DO NOT use this vacuum with damaged cord or plug. If the vacuum is not working as it should, because it has been dropped, damaged, left outdoors or dropped into water, contact an authorized service center or factory.
- DO NOT pull the vacuum by the cord, use cord as a handle, close a door on the cord or pull cord around sharp edges and corners. DO NOT run vacuum over the cord. Keep the cord away from heated surfaces.
- DO NOT unplug the vacuum by pulling on the cord. To unplug, grasp the plug, not the cord.
- DO NOT handle the vacuum plug or vacuum with wet hands.
- DO NOT put any objects into openings. DO NOT use with any openings blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
- Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
- DO NOT pick up anything that is smoking or burning such as cigarettes, matches, or hot ashes.
- DO NOT use without dust bag and/or filters in place for dry operation and wet adaptor for wet operation.
- Turn OFF all the controls before unplugging.
- Use extra care when cleaning on stairs.
- DO NOT use this vacuum to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
- DO NOT use where anesthetics or oxygen are used.
- Replace damaged or worn parts immediately with genuine original equipment parts to maintain safety and to protect your limited warranty.
- DO NOT use an extension cord unless absolutely necessary. If an extension cord is used, then wire size must be #14 gauge or larger and should not exceed 50 feet in length. The extension cord must be three-wire type to insure GROUNDING protection.
This vacuum must be connected to a properly grounded outlet only. See grounding instructions (Page 3). If your vacuum has an outlet for a motorized power nozzle, always turn the vacuum OFF before connecting or disconnecting the motorized nozzle.
SAVE THESE INSTRUCTIONS
GROUNDING INSTRUCTIONS
DANGER
Improper use of the grounding plug can result in a risk of electric shock.
Electrical equipment must be grounded. If it should mal-function or breakdown,
grounding provides a path of least resistance for electrical current to reduce
the risk of electric shock. This vacuum is equipped with a cord having an
equipment-grounding conductor and grounding plug.
The plug must be inserted into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
If repair or replacement of the cord or plug is necessary, DO NOT connect the
grounded wire to either flat blade terminal.
The wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire.
GROUNDING METHODS
This electric equipment is for use on a nominal 120 volt circuit, and has a
grounded plug that looks like the plug illustrated in (Fig A). A temporary
adaptor that looks like the adaptor illustrated in (Fig B & C) may be used to
connect this plug to a 2-pole receptacle as shown in (Fig B) if a properly
grounded outlet is not available.
The temporary adaptor should be used only until a properly grounded outlet
(Fig A) can be installed by a qualified electrician.
The green color rigid ear, lug or the like extending from the adaptor must be
connected to a permanent ground such as a properly grounded outlet box cover.
Whenever the adaptor is used, it must be held in place by a metal screw (Fig
C).
WARNING:
Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or service person if you
are in doubt as to whether the outlet is properly grounded.
DO NOT modify the plug provided with the equipment. If it will not fit the
outlet,have a proper outlet installed by a qualified electrician.
Note: In Canada, the use of a temporary adaptor is not permitted by the
Canadian Electrical Code.
CARE OF THIS VACUUM
Treat this vacuum as you would any other high grade precision made product.
Dropping, unreasonable bumping across thresholds and other misuses may result
in a damaged unit which will not be covered by warranty.
When not in use, the power cord should be wrapped around the motor head for
storage.
Read this manual completely before operating this vacuum. It is important to
follow instructions in this manual to prevent the possibility of injury or
damage to the user and/or vacuum.
VACUUM TANK ASSEMBLY
4-Caster Tanks
This vacuum requires some assembly.
- Carefully remove and set aside motor head and filter assembly
- Turn tank upside down. Poly Tanks: Press caster into plastic socket until bottom of stem fits flush against plastic socket.
Steel Tanks: Insert casters into caster mount assemblies.
Glidemobile Tank w/Handle
This vacuum is shipped with the handle in the storage position and must be moved to the operating position
- Firmly grasp speed pin on each side of handle and pull up and out.
- Pulling handle slowly away from the tank, align front handle holes with holes in handle bracket.
- Insert speed pins through holes on both sides, locking handle in position.
Attach tool caddy. (Not included with all models).
HOSE, WAND & TOOL ASSEMBLY
Hose & Swivel Connector
The hose and swivel connector are pre-assembled at the factory. To attach the swivel connector to intake fitting on vacuum tank:
- Line up swivel connector slots with retaining rivets on the intake.
- Insert swivel connector and twist clockwise until rivets reset against slot end.
1 1/4″ Tool Kit Assembly
Wand Assembly: Both sections are exactly the same. Slide the tapered end
of one section into the slotted end of the other wand section.
Attach Hose: Slide curved elbow on hose into wand end with slots on the
side.
Install Tool: Insert tool into the tapered end of the wand.
11/2″ Tool Kit Assembly
Wand Assembly: Align button lock of upper wand section with the opening
for button lock in the lower wand section and push sections together.
Attach Hose: Slide free end of hose into the grooved end of upper wand.
Install Tool: Turn wand nut counter-clockwise approximately (4) complete
turns. Insert the tool into wand nut and coupling. While holding tool in
place, turn nut clockwise until wand nut is fully locked.
CAUTION:
Exercise caution when handling the motor head.
Dropping the motor head may cause permanent damage to internal components.
DRY OPERATION
WARNING:
Electric shock could occur if used on wet surfaces DO NOT expose to rain –
Store Indoors.
Dry (only) vacuums are equipped with an air-thru motor are designed for dry
pick-up only.
Wet/dry vacuums are equipped with a bypass motor can be used for dry and wet
pick-up.
When ordered to be used as a dry vacuum, the unit is shipped with a dry filter
only.
Dry Filter Installation
- Remove the motor head and set aside. Empty filters, hose and other attachments that may be packed in the tank.
- Install a disposable paper filter bag as illustrated on the bag, attach cloth filter to wire filter frame, set filter assembly on tank, replace motor head and snap down holddown clamps.
Dry Filter
Maintenance
In order to maintain maximum vacuum cleaner efficiency it is important to
clean the cloth filter each time the tank is emptied.
To clean the cloth filter, shake off loose particles and brush exposed surface
with a soft bristle brush.
NOTE: DO NOT WASH, shrinkage to the cloth and damage to the gasket can
occur.
WET/DRY OPERATION
WARNING:
To avoid electric shock DO NOT expose to rain. Store Indoors.
Electric shock could occur if power nozzle is used on wet surfaces.
Adaptor w/Foam Filter Shipped w/Poly Tank Vacuums
When ordered as a wet/dry vacuum, this unit is shipped with a dry filter for
dry pickup and wet adaptor for liquid recovery. Follow instructions on page 5
for dry operation
Wet Pick-Up Adaptor Installation
The safety float located in the protective frame of the wet adaptor stops the
vacuum action of motor head when maximum recovery of liquid is reached.
Adaptor w/Wire Cage Shipped w/Steel Tank Vacuums
- Disengage the three (3) clamps that hold the motor head to the tank and carefully set aside.
- Remove the dry filter assembly and disposable paper filter bag.
- Set the wet adaptor on the tank, replace the motor head and snap down the holddown clamps.
Note: The wet pickup adaptor on some motor head are permanently mounted and are not removed for dry pickup.
FILTER INSTALLATION & REMOVAL
Paper Bag & Cloth Filters Installation
- Expand paper filter bag pleats, then grasp scored ends of cardboard and pull forward completely onto inlet tube as close to tank wall as possible.
- Position cloth filter assembly on the tank, then place motor head on tank and close clamps.
Loaded Filter Bag Removal
- Remove motor head and cloth filter assembly and lay cleaner on its side with inlet tube on top.
- Remove filter bag from inlet and pull bag out of tank, using care not to puncture bag with inlet tube.
- Reseal cardboard flap that covered filter bag opening. Install a new paper filter bag.
CARE OF WET ADAPTOR W/FOAM FILTER
The foam filter on the wet adaptor for the poly tanks MUST be washed after each use or the vacuum’s performance will be greatly reduced, and also checked for clogging, wear and tear. If the filter is clogged with dirt, lint, etc., it won’t work.
To Clean Foam Filter:
- Remove the motor head assembly from the tank.
- Slide foam sleeve down off the plastic float cage.
- Wash out the foam sleeve with water and a mild detergent, rinse out with clean water until the water is clear.
- After cleaning the foam filter, check it for signs of wear and tear. Replace if there are holes in the foam material large than a normal pore size. Reorder part no 365300 from your distributor.
To Install Foam Filter:
- Gently pull the foam filter up and over the plastic float cage until it covers all the cage openings.
REMOVAL OF LIQUIDS FROM VACUUM TANKS
Important
DO NOT store the vacuum with any liquids inside the tank. Before storing or
converting over for dry pickup run the emptied vacuum for approximately 5
minutes to eliminate moisture in the tank hose and tools.
Tanks without Drain Valves
-
Disengage clamp from tank, remove motor head and wet pickup adaptor.
Carefully set aside. -
Pour liquid from tank into suitable drain.
Steel Tanks w/Drain Valves
- Center the drain valve over a drain in the floor.
- Open drain valve by turning the valve counterclockwise and continue turning until the desired flow is reached.
- After the tank is drained, and before closing the drain valve make sure that there are no obstructions that will prevent the valve from sealing. Turn valve clockwise until it is fully closed and sealed.
Poly Tanks w/ Gate Valves
- Center the tank’s gate valve over a floor drain.
- Pull up on the gate valve handle to empty the tank.
TROUBLE SHOOTING GUIDE
CAUTION:
Always disconnect power cord before servicing vacuum.
PROBLEM: Loss of Vacuum.
CAUSE: | SOLUTION: |
---|
1] Full disposable paper filter bag.
2] Dry filter assembly clogged.
3] Clogged hose or wand.
4] Tank rim damaged.
5] Loose or broken fan.
6] Motor not working.
7] Float not functioning.
8] Gasket worn.| 1] Replace disposable paper filter bag.
2] Clean cloth filter.
3] Remove obstruction.
4] Replace tank.
5] Contact manufacturer or authorized service center.
6] Contact manufacturer or authorized service center.
7] Check to see if ball on rod moves freely or tank is full.
8] Replace gasket.
PROBLEM: Motor is not running.
CAUSE: | SOLUTION: |
---|
1] Broken switch.
2] Power cord defective.
3] Motor defective.
4] Blown fuse or tripped circuit breaker.| 1] Contact manufacturer or
authorized service center.
2] Contact manufacturer or authorized service center.
3] Contact manufacturer or authorized service center.
4] Replace fuse or reset circuit breaker.
PROBLEM: Dust blowing from vacuum when running.
CAUSE: | SOLUTION: |
---|
1] Full disposable paper filter bag.
2] Disposable paper filter bag not installed properly or off inlet tube.
3] Cloth filter bag dirty.
4] Cloth or paper filter bag is torn.
5] Paper filter bag is not installed.| 1] Replace disposable paper filter bag.
2] Reinstall properly or replace disposable paper filter bag.
3] Clean cloth filter bag.
4] Replace.
5] Install paper filter bag.
PROBLEM: Water blowing from vacuum when running.
CAUSE: | SOLUTION: |
---|
1] Tank is full of liquid.
2] Sudsy or foamy liquid is being picked up.| 1] Empty tank.
2] Add defoamer to tank.
WARNING:
Repairs should only be performed by an authorized service center
Address:
777 South Street
P.O. Box 2310
Newburgh, N Y 12550-0606
TEL:
800-835-7812
845-565-8850
FAX:
800-752-6883
845-565-9392
URL:
www.mastercraftusa.com
E-mail:
mail@mastercraftusa.com
Part No 335797 Rev D – W/D Vacuum Manual Printed in USA 07/19/04