AQiX Water Dosing Instrument
Control elements
1 | Display |
---|---|
2 | Key fi eld |
3 | Batt ery compartment |
4 | Connecti on thread 3/4“ for hose coupling |
5 | Sieve insert |
6 | Retaining bracket |
7 | Water outlet |
8 | Storage tank for quantity 1 |
9 | Storage tank for quantity 2 |
10 | Manual dosing/zeroing |
11 | Setting the quantity +/- |
12 | Start butt on / pause |
You have purchased the new AQiX water dosing instrument. Please note that this
is a meter and it should be handled with care. These instructi ons contain
important and useful informati on for how you should use the instrumenPlease
read the instructi ons carefully.
The numbers in the text relate to the overview on page 2.
Technical data
Measurable water quantity: | 1 – 99 litres |
---|---|
Min. / max. operating pressure | 2 – 6 bar |
Device operating temperature | + 5°C – + 50°C |
Flow medium | Clear freshwater |
Flow speed min. – max. | 10 ltr/min – 25 ltr/min |
Max. water temperature | + 40°C |
Accuracy | 1-3 litre ± 60 ml > 3 l ± 2% |
IP protecti on class | IP 64 |
Batteries | 2 x AA/IEC LR6 1.5 V |
Weight | 688 grammes |
Intended use
The Collomix AQiX water dosing system is intended for use by professionals or
trained personnel on constructi on sites for the precise additi on of water
for mixing building chemical products (such as mortar, plaster, screed,
concrete, fillers and the like).It is used to precisely meter amounts of
water.
The water dosing system may only be used with clear freshwater at a water
temperature of up to 40°C.
The Collomix AQiX water dosing system is not designed for industrial use.
It is not permitted to use the meter with salt water, chemicals, foodstuff s,
spirits, highly fl ammable and explosive substances as well as compressed air.
Using these substances may destroy the instrument.
The operating temperature must be between +5°C and +50°C. Do not expose the
instrument to direct sunlight for longer periods of ti me.
The water pressure in the line must be between at least 2 and a maximum of 6
bar so that the instrument works flawlessly.
Please note that this instrument is not a calibrated meter.
Fluctuations can be caused by factors such as varying water pressure, etc.
Safety information
WARNING
WARNING: Read all safety information and instructions.
Failure to observe the safety information and instructions may result in injuries or damage to the instrument.
Store these instructions for the future.
The instrument may only be used by persons familiar with the operating instructions and the applicable regulations regarding occupational safety and accident prevention.
For safety reasons, children and adolescents under the age of 16 as well as persons who have not familiarised themselves with this operating manual may not use this product.
Persons with restricted physical or mental abilities may only use the product if supervised or instructed by a competent person.
Children must be supervised in order to ensure that they do not play with the product.
Never use the instrument if you are tired or ill or under the influence of alcohol, drugs or medication.
ATTENTION!
Do not use in freezing conditi ons. Freezing water will destroy the instrument.
Only connect the supply hose to the provided connecti on, not to the water outlet!
Only intended to be used with the suitable hose couplings with ¾“ thread.
Avoid tensile loads: Do not pull at the connected hose.
Assembly/commissioning
The AQiX water dosing system is set to the unit of “litres” exworks.
The instrument is delivered with a standard ½“ hose connection.
This can be unscrewed and replaced with a different tap connection, such as
with a bayonet coupling.
Standard hose couplings with 1/2“ or 3/4“ hose connection can be used as a
quick-release or bayonet coupling.
Connect the water hose to the meter. The water hose may not be pressurised.
Only connect the hose to the hose coupling. No hose may be connected to the
water outlet (7). IMPORTANT: venting
After every connection made to the water hose, first make sure that the air
can escape from the instrument.
- Press the “START/PAUSE” (12) button to switch on the instrument.
- Set the display to “0” with the “0.00 – Man.” (10) button.
- Keep holding the “START/PAUSE” (12) button until the water flows out without any interruption.
Start dosing:
Press the “START/PAUSE” (12) button to start the metering.
You can interrupt the metering process. Press the “START/PAUSE” button to do
this. Pressing the button again starts the metering process where it was
interrupted.
Storing a metering quantity
Frequently used metering quantities can be saved by pressing the “M1” / “M2”
(8+9) buttons. Set the desired quantity value with the “+” and “-” button.
Then hold “M1” / “M2” for 2 seconds until the value in the display flashes.
Press “M1” / “M2” to call up the stored value. It will appear in the display.
Manual metering:
Press the “Man/0.00” button (10). Then press “START/ PAUSE” (12). The water
will run for as long as you hold down the button. The dispensed quantity of
water is shown in the display.
Converting the unit of measure:
The water dosing system can be used with three different units of measure:
Litres, quarts and US gallons.
To switch between them, hold the “Man/0.00” button for 5 seconds until 0
appears in the display. Set the desired number for the respective unit of
measure using “+” and “-”. Confirm each digit with the “START/PAUSE” button.
Finally press Play twice. The instrument switches off and changes the mode.
Value 100 = litres | 200 = quarts | 300 = gallons
You can hold the instrument in your hand for metering or hang it on the mixing
bucket or on the mixing bucket of a mixer.
The instrument is hung between the water outlet (7) and the retaining bracket
(6)
Decommissioning
Turn off the water supply at the water tap.
Completely empty the instrument and press the “START/PAUSE” butt on.
Disconnect the water hose. Shake out the AQiX.
The product must be stored so it cannot be accessed by children.
Store the water dosing system in a dry, closed and frost- proof locati on,
ideally in the case it comes in.
Electric power supply
The instrument is operated by two AA batt eries.
For safety reasons, only 2 x AA / IEC LR6 1.5V batteries (alkaline manganese)
may be used.
IMPORTANT!
The instrument may not be operated with rechargeable AA batteries.
Disposal – according to EU directive 2002/96/EC
Do not dispose of electronic items together with house-hold waste.
The instrument, batteries and packaging should be introduced into an
environmentally friendly recycling system.
IMPORTANT! Dispose of the product through your local recycling collection
point
Battery disposal:
Return used batteries to the point of sale or dispose of them through your
local waste disposal point. Only dispose of the battery in the discharged
state.
Warranty
The manufacturer offers a product warranty within the scope of the delivery
terms and in accordance with legal/ country-specific regulations. Please
include your payment receipt or delivery note with any warranty claims.
Please return the instrument to us if you detect any irregularities.
Complaints/claims can only be considered if the instrument is delivered to the
Collomix Service department in a complete and undismantled state.
Any damage resulting from normal wear, overload, improper handling, non-
approved accessories or insufficient maintenance shall be exempt from the
warranty.
Any repairs carried out by third parties shall release us from any warranty
obligation.
Any structural or functional changes to the instrument not authorised by us
shall result in the invalidation of the warranty as well as the declaration of
conformity.
Service address
In case of repair, please contact your dealer or country distributor. You can
find this out via our website.
www.collomix.com
Certificate of conformity
We hereby declare on our sole authority that this product complies with the
following standards or normative products:
EN 61000-6-3:2011 according to the provisions of the directives 2014/30/EU,
2011/65/EU (RoHS).
Gaimersheim, 2019-09-18
Alexander Essing
Management
Technical documentation to be requested from:
Collomix GmbH
Technical Development Department
Daimlerstr. 9, 85080 Gaimersheim, Germany
Care and maintenance
Clean equipment:| Keep the instrument clean and remove any dirt immediately.
Clean the instrument with a damp cloth and a mild cleaning detergent (soap).
Do not use any cleaning agents containing solvents.
---|---
Changing the batteries:| To change the batteries, open the battery compartment
(3) cover using a screwdriver. Remove the old batteries.
Insert the new batteries (AA) in the battery compartment according to the
labelling. Remove the rubber seal from the cover and clean it. Do not damage
the seal. We recommend lubricating the seal with silicone grease.
Reinsert the rubber seal into the groove of the cover, ensuring the seal fits
exactly.
Before screwing the cover back on, make sure that the rubber seal is not
crushed. You can tell that a seal is not properly seated as the gap in the
cover is not parallel.
Place the cover so that it is level and screw it back into place with the 3
screws.
If the seals are not inserted correctly, this may impair the leak-tightness of
the instrument. Do not reuse damaged seals.
Replacing the hose connection:| Loosen by turning counter-clockwise
Place the new hose coupling with seal on the thread and tighten in the
clockwise direction.
Cleaning the screen:| There is a particulate screen in the water supply (5)
that holds back larger particles in the supply water. It is recommended to
clean the screen from time to time.
Unscrew the hose connection as described above.
Use pliers to grab the screen at the protruding screen clip and pull it out.
Clean the screen under flowing water and re-insert it.
Screw the hose connection back on.
Back-flushing:| There is also a screen before the water outlet (7). If the
amount of water decreases significantly, this needs to be cleaned.
The hose must be connected to the water outlet only for this reason and this
reason only. At the same time, the second screen at the water supply (5) must
be removed (see above). Then flush the instrument backwards to remove the
deposits.
Then disconnect the hose and re-insert the screen at the water supply.
Faults – Troubleshooting
Notification in the display | Description | Rectification |
---|---|---|
BAT notification in the display area visualizes that the battery is empty |
Change the batteries
| Display of a circumferential line visualizes that there is no water in
the instrument| • Ensure a water supply to the instrument
• Check whether the instrument inlet is dirty and remove any dirt if necessary
| No notification in display after pressing the “START/PAUSE” button| • Change
the batteries
• If there is still no notification after changing the batteries, then send in
the instrument for repair
Hersteller: Collomix GmbH
Daimlerstraße 9
85080 Gaimersheim
Deutschland
www.collomix.com
Subject to change without notice
Art.nr . 19387 #4 – 0124 – © Collomix GmbH
Documents / Resources
|
Collomix AQiX Water Dosing
Instrument
[pdf] Instruction Manual
2900102700 AQiX Water Dosing Instrument, 2900102700, AQiX Water Dosing
Instrument, Water Dosing Instrument, Dosing Instrument, Instrument
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>