Collomix 19042 AQiX Water Dosing System
Product Information
The product is a water dosing system called AQiX. It is designed for professionals or trained personnel to accurately add water for mixing building chemical products such as mortar, plaster, screed, concrete, fillers, and more. The system allows for precise metering of water quantities. It is not intended for industrial use and should not be used with salt water, chemicals, foodstuffs, spirits, highly flammable and explosive substances, or compressed air as it may damage the device. The device operates within a minimum and maximum operating pressure range and has a specific IP protection class. It is important to note that the device is not a calibrated meter and fluctuations in measurements can occur due to factors like varying water pressure.
Control elements
- Display
- Key field
- Battery compartment
- Connection thread 3/4″ for hose coupling
- Sieve insert
- Retaining bracket
- Water outlet
- Storage tank for quantity 1
- Storage tank for quantity 2
- Manual dosing/zeroing
- Setting the quantity + / –
- Start button/pause
You have purchased the new AQiX water dosing system. Please note that this is a meter and it should be handled with care. These instructions contain important and useful information for how you should use the device. Please read the instructions carefully. The numbers in the text relate to the overview on page 2.
Technical data
Intended use
The Collomix AQiX water dosing system is intended for use by professionals or trained personnel on construction sites for the precise addition of water for mixing building chemical products (such as mortar, plaster, screed, concrete, fillers and the like). It is used to precisely meter amounts of water. The water dosing system may only be used with clear freshwater at a water temperature of up to 40°C. The Collomix AQiX water dosing system is not designed for industrial use. It is not permitted to use the meter with salt water, chemicals, foodstuffs, spirits, highly flammable and explosive substances as well as compressed air. Using these substances may destroy the device. The operating temperature must be between +5°C and +50°C. Do not expose the device to direct sunlight for longer periods of time. The water pressure in the line must be between at least 2 and a maximum of 6 bar so that the device works flawlessly. Please note that this device is not a calibrated meter. Fluctuations can be caused by factors such as varying water pressure, etc.
Safety information
WARNING: Read all safety information and instructions. Failure to observe the safety information and instructions may result in injuries or damage to the device.
- Store these instructions for the future.
- The device may only be used by persons familiar with the operating instructions and the applicable regulations regarding occupational safety and accident prevention.
- For safety reasons, children and adolescents under the age of 16 as well as persons who have not familiarised themselves with this operating manual may not use this product.
- Persons with restricted physical or mental abilities may only use the product if supervised or instructed by a competent person.
- Children must be supervised in order to ensure that they do not play with the product.
- Never use the device if you are tired or ill or under the influence of alcohol, drugs or medication.
ATTENTION!
- Do not use in freezing conditions. Freezing water will destroy the device.
- Only connect the supply hose to the provided connection, not to the water outlet!
- Only intended to be used with the suitable hose couplings with ¾” thread.
- Avoid tensile loads: Do not pull at the connected hose.
Assembly/commissioning
The AQiX water dosing system is set to the unit of “litres” ex works.
The device is delivered with a standard ½” hose connection. This can be
unscrewed and replaced with a different tap connection, such as with a bayonet
coupling. Standard hose couplings with 1/2″ or 3/4″ hose connection can be
used as a quick-release or bayonet coupling.
Connect the water hose to the meter. The water hose may not be pressurized. Only connect the hose to the hose coupling. No hose may be connected to the water outlet (7).
IMPORTANT: venting
After every connection made to the water hose, first, make sure that the air
can escape from the device.
- Press the “START/PAUSE” (12) button to switch on the device.
- Set the display to “O” with the “0.00 – Man.” (10) button.
- Keep holding the “START/PAUSE” (12) button until the water flows out without any interruption.
Operation
-
Switching on the device:
The AQiX water dosing system is switched on using the “START/PAUSE” (12) button. The unit first appears in the display and then the last set quantity. -
Setting the metering quantity:
Adjust the metering quantity using both keys (11) “+” and “-“. The water quantity can be set in increments of 0.1 litres. Keep the button depressed to advance quickly. -
Start dosing:
Press the “START/PAUSE” (12) button to start the metering. You can interrupt the metering process. Press the “START/ PAUSE” button to do this. Pressing the button again starts the metering process where it was interrupted. -
Storing a metering quantity:
Frequently used metering quantities can be saved by pressing the “MI” / “M2” (8+9) buttons. Set the desired quantity value with the “+” and “” button. Then hold “M1” / “M2” for 2 seconds until the value in the display flashes. Press “M1” / “M2” to call up the stored value. It will appear in the display. -
Manual metering:
Press the “Man/0.00” button (10). Then press “START/ PAUSE” (12). The water will run for as long as you hold down the button. The dispensed quantity of water is shown in the display. -
Converting the unit of measure:
The water dosing system can be used with three different units of measure: Litres, quarts and US gallons. To switch between them, hold the “Man/0.00” button for 5 seconds until O appears in the display. Set the desired number for the respective unit of measure using “+” and “-“. Confirm each digit with the “START/PAUSE” button. Fi- nally press Play twice. The device switches off and changes the mode.
Value 100 = litres | 200 = quarts | 300 = gallons
Decommissioning
- Turn off the water supply at the water tap.
- Completely empty the device and press the “START/PAUSE” button.
- Disconnect the water hose. Shake out the AQiX.
- The product must be stored so it cannot be accessed by children.
- Store the water dosing system in a dry, closed, and frostproof location, ideally in the case it comes in.
Electric power supply
The device is operated by two A batteries. For safety reasons, only 2 × AA /
IC LR6 1.5V batteries (alkaline manganese) may be used.
IMPORTANT! The device may not be operated with rechargeable AA batteries.
Disposal – according to EU directive 2002/96/EC
Do not dispose of electronic items together with household waste. The device,
batteries and packaging should be introduced into an environmentally friendly
recycling system.
IMPORTANT! Dispose of the product through your local recycling collection
point.
Warranty
The manufacturer offers a product warranty within the scope of the delivery terms and in accordance with legal/ country-specific regulations. Please include your payment receipt or delivery note with any warranty claims. Please return the device to us if you detect any irregularities. Complaints/claims can only be considered if the device is delivered to the Collomix Service department in a complete and undismantled state. Any damage resulting from normal wear, overload, improper handling, non-approved accessories or insufficient maintenance shall be exempt from the warranty. Any repairs carried out by third parties shall release us from any warranty obligation. Any structural or functional changes to the device not authorized by us shall result in the invalidation of the warranty as well as the declaration of conformity.
Service address
In case of repair, please contact your dealer or country distributor. You can
find this out via our website.www.collomix.com
Certificate of conformity
We hereby declare on our sole authority that this product complies with the
following standards or normative products: EN 61000-6-3:2011 according to the
provisions of the directives 2014/30/EU, 2011/65/EU (RoHS).
Gaimersheim, 2019-09-18
Alexander Essing
Management
Technical documentation to be requested from: Collomix GmbH
Technical Development Department: Daimlerstr. 9, 85080 Gaimersheim,
Germany
Care and maintenance
Faults – Troubleshooting
Hersteller: