ENVIRO C-16873 Gas Fireplaces
Specifications
- C-16873 C60 Fireplace
- Minimum Framing Dimensions:
- Depth: 20″ (508 mm)
- Width: 71″ (1397 mm)
- Header Height: 38″ (965 mm)
- Rough Opening Height: 43.5″ (1105 mm)
- Enclosure Ceiling: 72″ (1829 mm)
FAQ
What are the minimum venting requirements for the C60 Fireplace?
The minimum venting requirements for the C60 Fireplace are a vent length of 20″ (509 mm).
Do I need a steel stud for installation if I’m not using the Combustible Facing Kit?
Yes, a steel stud is required if you are not using the Combustible Facing Kit for installation.
What is the minimum distance to the wall from the standoff for the Cool Surface System?
The minimum distance to the wall from the standoff for the Cool Surface System is 5.00″ (13 cm).
REFER TO OWNER’S MANUAL FOR SPECIFIC INSTALLATION REQUIREMENTS AND ADDITIONAL PRODUCT INSTRUCTIONS
Minimum Framing Dimensions
Clearance to Combustibles
Non-Combustible Board Placement
Minimum Venting Requirements
Minimum permitted venting is shown below. The framing height to the center of the thimble is 62”. Minimum venting must include a 24” vertical section and a 90 degree elbow which is then terminated horizontally. For a vertical termination please follow the vent pipe manufacturer’s installation instructions for vertical vent termination framing. A minimum of 1 in. (25 mm) clearance on all sides of the vertical vent pipe must be maintained. For every 12” of horizontal run there must be a 1/4” of rise. 1” of clearance between framing and venting must be maintained at all times. 2” above the venting and 3” above an elbow.
Fireplace Dimensions
Mantel Projections
Mantel graph dimensions are measured from the bottom of the fireplace, if you wish to reference the mantel height from the tiling edge subtract 15 inches (381mm) from the mantel height depicted on the graph. If you plan to install a TV above your fireplace refer to the appropriate section of the owner’s manual for available options. It is acceptable to install a combustible mantel over top of the non-combustible board. If you are activating the Cool Surface System you are eligible to subtract 12” (305mm) from the mantel height shown in this diagram. See page 6 for more details.
OPTIONAL STEP Cool Surface System Part 1
Dimensions
OPTIONAL STEP Cool Surface System Part 2
Framing & Rough Opening – Front Vent
CSS Outlet Min. Top and Bottom standoff = 25/8” (6.7 cm) All C Series
Venting Clearances – Front Vent
Shown here are the minimum framing and clearances for the CSS when the
fireplace is installed with the minimum allowable vent length:
Min. Ceiling Clearance from top of CSS outlet = 4” (10.2 cm)
Min. Ceiling Clearance in wall from top of CSS Body = 55/8” (14.3 cm) CSS Body
Min. Rear standoff = 2¾” (69.8 cm)
OPTIONAL STEP Cool Surface System Part 3
Framing & Clearances – CSS Side Vent
OPTIONAL STEP Cool Surface System Part 4
Framing & Revised Mantle Clearances – Front Vent
Framing & Revised Mantle Clearances – Side Vent
TV Installation Considerations
If you are planning to mount a TV above your fireplace some considerations must be made to ensure it is protected from the heat.
During testing temperatures did not exceed 121°F (49°C) midway up the front
wall (see figures on right).
There is no guarantee that these temperatures will not harm the longevity of
your TV. Make sure to consult your TV manufacturer’s specifications to find
the maximum allowable operating temperature. Since every home and installation
is unique, temperatures should be verified at the time of install if possible.
If desired, front wall temperatures can be lowered to 104°F (40°C) with the
use of a mantle (see CSS TV clearances with Mantle figure). See revised mantle
clearances chart above. A TV should not be installed if temperatures exceed
the manufacturers maximum allowable temperature.