  • Product Name: VK1240 RGBW ATLAS Wash Light
  • Usage: Indoor
  • Maximum Ambient Temperature : 40°C
  • Unit Surface Temperature: Up to 85°C during operation
  • Light Sources: 12 x 40W 4in1 RGBW LED
  • Beam Angle: 3.5°~ 45°
  • Power Consumption: 380W
  • Power Voltage: AC 100-240V, 50/60Hz
  • Dimension: 324x240x377mm
  • Net Weight: 9Kgs
  • Packing size: 400x310x430mm

Safety Instructions
Please follow these safety instructions for the proper and safe operation of the VK1240 RGBW ATLAS Wash Light:

  1. Keep the User Guide for future reference.
  2. Check for transportation damage before using the unit.
  3. Ensure power supply voltage and frequency match unit requirements.
  4. Ground the yellow/green conductor to earth to avoid electric shock.
  5. Operate the unit in a dry location with adequate ventilation.
  6. Ensure no flammable materials are close to the unit during operation.
  7. Use safety cable when fixing the unit.
  8. Avoid touching the housing bare-handed during operation.
  9. Allow the unit to cool down for about 15 minutes before servicing.
  10. If serious operating problems occur, stop using the unit immediately and contact authorized technical assistance.
  11. Avoid touching any wires during operation to prevent electric shock.

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.

  • Unpack and check carefully there is no transportation damage before using the unit.
  • Before operating, ensure that the voltage and frequency of the power supply match the power requirements of the unit.
  • It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
  • The unit is for indoor use only. Use only in a dry location.
  • The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
  • Disconnect the main power before replacement or servicing.
  • Make sure there are no flammable materials close to the unit while operating as it is fire hazard.
  • Use safety cable when fixing this unit. Do not handle the unit by taking its head only, but always by taking its base.
  • Maximum ambient temperature is Ta: 40. Do not operate it where the temperature is higher than this Unit surface temperature may reach up to 85. Do not touch the housing bare hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
  • In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
  • Do not touch any wire during operation as high voltage might be causing electric shock.

Warning:

  • To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
  • Do not open the unit within five minutes after switching off.
  • The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.

Caution:
There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.

Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people.

Control

  • DMX Channel : 16/21 Channel
  • Control Modes: DMX512/mater-Slave/AutoRun/Music

Pan/Tilt

  • Pan/Tilt: 540°or 360°in optional / 270°
  • Pan/Tilt Resolution: 8/16 bit

Construction

  • Display: 1.8 TFT Colorful Display
  • Data In/Out socket: 3-pin & 5-pin XLR sockets
  • Power Socket: PowerCon in/out
  • Protection Rating: IP20

Features

  • Motorized linear zoom system, zoom range: 3.5°~45°
  • Outstanding color macro effect
  • Dimmer: 0~100% smooth dimming
  • Variable strobe effects Fast, quiet operation and flicker-free

Outstanding color macro effect

  • Dimmer: 0~100% smooth dimming
  • Variable strobe effects Fast, quiet operation and flicker-free

statement
The product has well capability and intact packing when leave factory. All of the user should comply with warning item and manual, any misuse cause of the damages are not included in our guarantee, and also can’t be responsible for any malfunction & problem owing to ignore the manual.

How To Control The Unit
The unit can be controlled using the following functions:

Danfoss-ECL-296-Home-Automation-System-Temperature-Controller-fig-
\(1\)

Display:

  • MENU: Select programming functions.
  • DOWN: Move backward in selected functions.
  • UP: Move forward in selected functions.
  • ENTER: Confirm selected functions.

Menu:

  1. Pan Degree
  2. Mic Sense
    • 540°
    • 360°
    • 001-100
  3. Language: English
  4. Sound control sensitivity adjustment
  5. Address Reverse
    • No Signal
    • Fan Set
    • Reset
    • Default

Set DMX Address Code

  1. Press “Menu” to “Set DMX Address”, and press the “ENTER” keys to enter into
  2. Show “Set DMX Address DMX Address:001”, Press the “UP and DOWN” keys to amended
  3. Press “ENTER” keys to save and Exit, Press the “MENU” Keys does not save and Exit

Menu|

  • Pan Degree

|

  • 1.540

---|---|---

  • 360

  • Mic Sense

| 001–100| Sound control adjusts sensitiveness

  • Language

|

  • English

 |  |

  • Chinese

---|---|---

  • No Signal

|

  • Black Out

  • Hold

  • Fan Set

|

  • Auto

  • Low

  • High

  • Reset

|

  • Yes

  • No

  • Default

|

  • Yes

  • No

  • Adjust

| Pass Word| ****

  • Pan

| Pan fine-adjust

  • Tilt

| Tilt fine-adjust

  • Focus

| Zoom fine-adjust

  • Rota: 0-255

| Rota fine-adjust

  • Red

|

Change the value, adjust the white balance

  • Green

  • Blue

  • White

Address| Set address code 001–512
Reverse|

  • Pan

|

  • Yes

  • No

  • Tilt

|

  • Yes

  • No

  • Display

|

  • Yes
    2.No

Inform

|

  • CH Value

| display all channel values

  • Temp/℃

| display led board temperature

  • Soft v.xxx

| software version number

Mode

|

  • DMX512

  • Auto

|

  • Master

  • Alone

  • Sound

|

  • Master

  • Alone

  • Manual

|

Master

|

  • Pan:0–255

  • Tilt:0–255

  • Focus):0–255

  • Red:0–255

Alone

|

  • Greed:0–255

  • Bule:0–255

  • White:0–255

  • Strobe:0-255

Channel

|

  • 16Channels

  • 21Channels

DMX channel´s functions and values (16/21DMX channels): Model 1 – CH16

Channel Display Function Value
CH-1 Pan Pan control 0 — 255
CH-2 Pan adjustment Pan adjustment 0 — 255
CH-3 Tilt Tilt control 0 — 255
CH-4 Tilt adjustment Tilt adjustment 0 — 255
CH-5 Pan/Tilt speed from fast to slow 0 — 255
CH-6 Zoom from small to big 0 — 255
CH-7 Dimming From dark to bright 0 — 255


CH-8

| ****


Strobe

| No| 0 — 3
From slow to fast| 4 — 203
Random strobe| 204 — 255
CH-9| Red| From dark to bright| 0 — 255
CH-10| Green| From dark to bright| 0 — 255
CH-11| Blue| From dark to bright| 0 — 255
CH-12| White| From dark to bright| 0 — 255


CH-13

| ****

Dimming Model

| Model -1| 0 — 49
Model -2| 50 — 99
 |  | Model -3| 100 — 149
---|---|---|---
Model -4| 150 — 255














CH-14

| ****












Color temperature

| No| 0—-15
R 100%, G up, B0%| 16—-35
R down, G 100%, B0%| 36—-55
R 0%, G 100%, B up| 56—-75
R 0%, G 100%, B up| 76—-95
R up, G0%, B 100%| 96—-115
R 100%, G 0%, B down| 116—-135
R 100%, G up, B up| 136—-155
R down, G down, B100%| 156—-175
R100%G100%B100%W100%| 176—-195
2800K| 196—-200
3200K| 201—-205
4000K| 206—-210
4500K| 211—-215
5000K| 216—-220
5600K| 221—-225
6500K| 226—-230
7000K| 231—-235
 |  | 7500K| 236—-240
---|---|---|---
8000K| 241—-255






CH-15

| ****





Macro Color

| No| 0 — 15
Zone -1| 16– 31
Zone -2| 32– 47
16 numbers 1 effect| ……
Zone -14| 224 — 239
Zone -15| 240 — 255


CH-16

| ****

Reset

| No| 0 — 250
Reset| 250- 255

Model 2 – CH21

Channel Display Function Value
CH-1 Pan Pan control 0 — 255
CH-2 Pan adjustment Pan adjustment 0 — 255
CH-3 Tilt Tilt control 0 — 255
CH-4 Tilt adjustment Tilt adjustment 0 — 255
CH-5 Pan/Tilt speed from fast to slow 0 — 255
CH-6 Zoom from small to big 0 — 255
--- --- --- ---
CH-7 Dimming From dark to bright 0 — 255

CH-8

| Dimming adjustment| Dimming adjustment| 0 — 255



CH-9

| ****


Strobe

| No| 0 — 3
From slow to fast| 4 — 203
Random strobe| 204 — 255
CH-10| Red| From dark to bright| 0 — 255
CH-11| Red adjustment| Red adjustment| 0 — 255
CH-12| Green| From dark to bright| 0 — 255
CH-13| Green adjustment| Green adjustment| 0 — 255
CH-14| Blue| From dark to bright| 0 — 255
CH-15| Blue adjustment| Blue adjustment| 0 — 255
CH-16| White| From dark to bright| 0 — 255


CH-17

| White adjustment| White adjustment| 0 — 255




CH-18

| ****



Dimming Model

| Model -1| 0 — 49
Model -2| 50 — 99
Model -3| 100 — 149
Model -4| 150 — 255


















CH-19


Color Temperature

| No| 0—-15
---|---|---
R 100%, G up, B0%| 16—-35
R down, G 100%, B0%| 36—-55
R 0%, G 100%, B up| 56—-75
R 0%, G100%, B up| 76—-95
R up, G 0%, B100%| 96—-115
R 100%, G 0%, B down| 116—-135
R 100%, G up, B up| 136—-155
R down, G down, B 100%| 156—-175
R100%G100%B100%W100%| 176—-195
2800K| 196—-200
3200K| 201—-205
4000K| 206—-210
4500K| 211—-215
5000K| 216—-220
5600K| 221—-225
6500K| 226—-230
7000K| 231—-235
7500K| 236—-240
8000K| 241—-255






CH-20

| ****





Macro Color

| No| 0 — 15
---|---|---|---
Effect -1| 16– 31
Effect -2| 32– 47
16 numbers 1 effect| ……
Effect -14| 224 — 239
Effect -15| 240 — 255


CH-21

| ****

Reset

| No| 0 — 250
Reset| 250- 255

LUX DateDanfoss-ECL-296-Home-Automation-System-Temperature-Controller-
fig- \(2\) Shape Danfoss-ECL-296-Home-Automation-System-Temperature-Controller-fig-
\(3\)

Troubleshooting

  1. Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:

  2. The unit does not work, no light and the fan does not work

  3. Check the connection of power and main fuse.

  4. Measure the mains voltage on the main connector.

  5. Check the power on LED.

  6. Not responding to DMX controller

  7. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.

  8. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.

  9. If you have intermittent DMX signal problems, check the pins on the connectors or on PCB of the unit or the previous one.

  10. Try to use another DMX controller.

  11. Check if the DMX cables run near or run alongside to high-voltage cables that may cause damage or interference to DMX interface circuit.

  12. One of the channels is not working well

  13. The stepper motor might be damaged or the cable connected to the PCB is broken.

  14. The motor’s drive IC on the PCB might be out of condition.

  15. Fixture Cleaning
    The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause a greater accumulation of dirt on the unit’s optics.

    • Clean with a soft cloth using normal glass cleaning fluid.
    • Always dry the parts carefully.
    • Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

FAQ (Frequently Asked Questions)

Q: What should I do if the unit shows signs of visible damage?
A: If the housing, lenses, or ultraviolet filter are visibly damaged, they must be replaced. Contact your nearest dealer for replacements.

Q: Can I attempt to repair the unit on my own?
A: No, there are no user-serviceable parts inside the unit. Do not attempt any repairs yourself. Contact an authorized dealer if service is needed.

Q: How should I handle the unit while fixing it?
A: Always use a safety cable when fixing the unit. Do not handle the unit by its head only; always hold it by its base to prevent damage.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals