QH Basic Quality Heating CV Clock Thermostat Instruction Manual

July 20, 2024
Quality Heating

Quality-Heating-logo

QH Basic Quality Heating CV Clock Thermostat

QH-Basic-Quality-Heating-CV-Clock-Thermostat-fig-1

Product Information

Product Specifications:

  • Power Supply : 2 x AAA batteries
  • Dimensions: 13.4 x 9.4 x 2.8 cm
  • IP Rating : IP30
  • Backlight: Yes
  • Color: White

Product Important Safety Information:

  • Do not let children play with the device.
  • Cleaning and user maintenance should not be done by children without supervision.
  • Avoid handling the device with wet or moist hands.
  • Do not expose the device to direct splashing water.
  • Do not sit on the device.
  • Keep the device out of reach of children and animals.
  • Do not use the device if it is defective.

Product Warranty:
Proper installation according to the provided instructions is required to claim the full 2-year warranty on the electrical operation of the thermostat.

Thermostat Connection:
The thermostat is an on/off type and does not modulate. Refer to your boiler manual for connecting it to your boiler. Connect the two wires from your boiler to the COM (Red) and NO (Blue) terminals as shown in the diagram.

Product Operation

Display and Buttons:
To turn the thermostat on/off, press the power button.

Instructions for First Use:

  1. Adjusting Hysteresis: Change the hysteresis setting from the default 1°C to 0.5°C for comfortable use in the Dutch climate. Refer to advanced settings item 2 on pages 3 and 4.
  2. Temperature Calibration: Verify if the displayed temperature matches the actual room temperature using an external thermometer. Adjust the displayed temperature on the thermostat using temperature calibration in advanced settings item 1 if needed. Refer to pages 3 and 4.
  3. Setting Day and Time:
  4. Turn on the thermostat.
  5. Press and hold the SET button for 5 seconds until the temperature display disappears, and the minute display starts blinking.
  6. Adjust minutes using the +/- buttons, press SET. Hours will blink.
  7. Adjust hours using the +/- buttons, press SET. The day of the week will blink. Set it using the +/- buttons and press SET.
  8. The day and time are now set.
  9. Selecting Mode: Press the PRG button to choose between the two available modes.

Frequently Asked Questions (FAQ)

  • How do I change the batteries in the thermostat?
    To change the batteries, locate the battery compartment, remove the old batteries, and insert new AAA batteries following the correct polarity.

  • Can I mount the thermostat on any type of wall?
    It is recommended to mount the thermostat on a stable wall surface. Avoid mounting it on surfaces prone to moisture or water exposure.

IMPORTANT SAFETY INSTRUCTION

  • Read all information in this manual carefully.
  • All wiring must be done according to local and national building standards and regulations.
  • Only use the thermostat as described in the manual.

INSTALLATION INSTRUCTION

  • Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.
  • Children are not allowed to play with the device. Cleaning and user maintenance shall not be made by children without supervision.
  • Place the device in an upright and stable position or hang it on the wall.
  • Do not handle the device with wet or damp hands. Do not expose the device to direct spraying water.
  • Do not sit on the device.
  • This device is not a toy! Keep out of reach of children and animals. Do not leave the appliance unattended during use without a thermostat.
  • Check accessories and connection parts for possible damage before each use of the device. Do not use defective equipment or parts.

GUARANTEE

We can only give you the full warranty if it is installed correctly in accordance with these instructions. The QH basic thermostat is a maintenance- free thermostat with a 2-year warranty on the electrical functioning of the elements.

THERMOSTAT CONNECTION

  • The thermostat is an on/off thermostat and therefore cannot modulate. For the connections to your boiler, please consult your boiler manual.
  • The two wires coming from your boiler must be connected to the COM (Red) and NO (Blue) terminals, see the diagram below.

SRVICE

QH-Basic-Quality-Heating-CV-Clock-Thermostat-fig-3

Turning the thermostat on/off
Press the on/off button to switch the thermostat on or off.

Adjust hysteria

  • The factory setting for the hysteresis is 1 C. For comfortable use in the
  • Dutch climate we recommend a hysteresis of 0.5 C. See advanced settings item 2. See pages 3 and 4.

Temperature calibration
Check with an external thermometer whether the displayed temperature corresponds to the room temperature. If this is not the case, adjust the temperature displayed on the thermostat using the temperature calibration in the advanced settings item 1. See pages 3 and 4.

Set day and time

  1. Turn on the thermostat.

  2. Press the SET button for 5 seconds, the temperature display will disappear from the screen and the minute display will flash.

  3. Set the minutes with the +/- buttons and press SET, the hours will flash.

  4. Set the hours with the +/- keys and press SET, the day of the week will flash.
    Set the day of the week with the +/- buttons and press SET.

  5. The day and time are now set.

Select mode
Press the PRG button to choose the desired mode, the thermostat has two modes:

  1. Manual mode (MAN)
  2. Programming mode (PRG)

Set program
The thermostat has a 5+1+1 programming function. This means that you must set the same program for Monday to Friday (period 1, days 1 to 5). You can set an individual program for Saturday (period 2, day 6) and Sunday (period 4, day 7). You can enter 4 switching points per period.

  1. Turn on the thermostat.
  2. Press the PRG button for a few seconds, the programming menu will appear on the display, days 1 to 5 will light up. This means that you are programming for these days. The current switching point is shown at the bottom right of the display. You can set 4 switching points per period.
  3. Select the desired time of the switching point with the +/- buttons and press the PRG button.
  4. Select the desired temperature and press the PRG button.
  5. 2 appears at the bottom right, this means that you are now programming switching point 2.
  6. Repeat steps 3 & 4 for all switching points from periods 1 to 3. So you set a total of 12 switching points.

Example of a program:

  • Period 1
    • Monday to Friday (1 to 5)
    • Switch point 1234
    • Time 6:308:0018:0022:30
    • Temperature 21182116
  • Period 2
    • Saturday (6)
    • Switch point 1234
    • Time 8:008:0018:0022:30
    • Temperature 21212116
  • Period 3
    • Sunday (7)
    • Switch point 1234
    • Time 9:0012:0019:0022:00
    • Temperature 21212116

Advanced settings
Turn off the thermostat and press for 5 sec. Press SET to open the advanced settings. The screen will turn on and the menu below will open. Use the PRG button to scroll through the menu items.

QH-Basic-Quality-Heating-CV-Clock-Thermostat-fig-4

Temperature calibration

  1. If desired, you can correct the built-in sensor of the thermostat. This can be a solution, for example, if you want to equate the thermostat with another existing thermostat. The range you can correct the sensor is minus 8 degrees Celsius ~ 8 degrees Celsius.
  2. Hysteresis Set the switch-on difference. The thermostat will switch on when the set temperature deviates from the measured room temperature by this value.
  3. Temperature limit Set the desired maximum temperature that can be set. Adjustable between 25~60 °C. The factory setting is 35 °C. This is only for the type with external floor sensor on the receiver. Not applicable for central heating installations.
  4. Program mode on the thermostat can be programmed for different days separately or the 5 working days and weekend days separately (5+1+1). 4 switching times can be set per day. See program setting instructions and preset program on page 2.
  5. Frost protection The frost protection can be switched on or off. When frost protection is enabled, it can be set to a temperature between 3 ~ 10 °C. When frost protection is enabled, the heating will be switched on when the temperature drops below the set value. The heating switches off when the temperature is 2 °C higher than the set temperature.
  6. Enable/disable open window detection When the thermostat detects a sudden drop in room temperature (factory setting 2 °C in 5 minutes) the heating will be switched off. The screen will show OP (OP mode enabled). The program will resume after 30 minutes (factory setting). The OP mode can be canceled by pressing any key. Turn this function ON (01) or OFF (00).
  7. Open window detection: Time setting The open window detection switches on when a large temperature drop is detected within a short time, for example when a window is open. This time can be adjusted from 2-30 minutes. Factory setting: 5 minutes. The OP mode can be canceled by pressing any key.
  8. Open window detection: Temperature drop The open window detection switches on when a large temperature drop is detected within a short time, for example when a window is open. The number of degrees by which the temperature must drop to enable the open window function can be adjusted from 2-4 °C. Factory setting: 2 °C The OP mode can be canceled by pressing any key.
  9. Open window detection: Return to program The open window detection switches on when a large temperature drop is detected within a short time, for example when a window is open. After a few minutes the thermostat will return to the regular program. The number of minutes the thermostat waits to resume the program can be adjusted from 10-60 minutes. Factory setting: 30 minutes. The OP mode can be canceled by pressing any key

Technical data and dimensions

  • Dimensions WxHxD in mm 135 x 87.5 x 23.2
  • Power supply 2x AAA battery (not included)
  • Relay contact 0.5A
  • Adjustable temperature 5 ~ 30 degrees Celsius
  • Ambient temperature Backlight White 0 ~ 50 degrees Celsius
  • Sensor type NTC 10K, 3950 Ohm at 25 degrees Celsius
  • Accuracy 0.5 degrees Celsius (0.5 °C increments )
  • Protection class IP30