FORTINET FS-624F FortiSwitch User Guide

July 20, 2024
FORTINET

FORTINET FS-624F FortiSwitch

FORTINET-FS-624F-FortiSwitch-PRODUCT

Specifications

  • Product: FortiSwitch 624F/648F Series
  • Models: FS-624F, FS-624F-FPOE, FS-648F, FS-648F-FPOE
  • Management Options: Local setup or Cloud management mode
  • Ports:
    • Ports 1 to 24 (RJ45): Support various link speeds with corresponding LED indicators
    • Ports 25 to 28 (SFP28): Support higher data rates with LED indicators

GUI Setup

  1. Connect the management computer to the device using an Ethernet cable.
  2. Access the GUI using the provided IP address and login credentials.

CLI Setup

  1. Connect the management computer to the device’s console port using the console cable.
  2. Configure the console settings as specified in the manual.

Cloud Management

  1. Register the device and obtain a cloud management license.
  2. Access the cloud management portal to manage your inventory list.

Installation:
Follow these steps to properly install the FortiSwitch device:

  • Install SFP modules if needed.
  • Securely attach the rack mount brackets and rails.
  • Ensure recommended clearance around the device.

FortiSwitch 624F/648F Series
FS-624F, FS-624F-FPOE, FS-648F, FS-648F-FPOE

Before you begin

Register your device to access FortiGuard updates, cloud management, firmware upgrades, technical support and warranty coverage.

https://support.fortinet.com

The Essentials

Default Logins https://192.168.1.99 Username: admin Password: leave blank

Fortinet Documents Library
For a detailed Administration Guide, up-to-date Hardware documentation and Reference Manuals, visit https://docs.fortinet.com/

Customer Service
For contracts, licensing, product registration and account management, contact FortiCare Support at https://www.fortinet.com/support/contact

Technical Support
To access our Resource Center, Professional Services and Technical Support Services, visit https://www.fortinet.com/support

Thank you for choosing Fortinet

Package Contents

FortiSwitch 624F/648F Series
FS-624F, FS-624F-FPOE, FS-648F, FS-648F-FPOE

FORTINET-FS-624F-FortiSwitch- \(2\)

Setup Options

Set up your Fortinet device locally or use cloud management mode.
FORTINET-FS-624F-FortiSwitch- \(3\)

Note: For static IP configuration, use 192.168.1.1 with subnet mask 255.255.255.0

Note: For a detailed CLI guide, visit docs.fortinet.com

Cloud Management
(Connect a port to the Internet)

  1. Visit support.fortinet.com to register your device and cloud management license
  2. Sign in at https://fortilan.forticloud.com to manage your Inventory List

FortiLink

FORTINET-FS-624F-FortiSwitch- \(5\)

  1. Login to the FortiGate and go to WiFi & Switch Controller -> FortiLink Interface
  2. Add a FortiGate Port in the FortiLink interface
  3. When the device is discovered, select Authorize

Optional: To automatically authorize the device upon discovery, enable “Automatically authorize devices” in the FortiLink Interface settings

SFP Modules

FORTINET-FS-624F-FortiSwitch- \(6\)

Rail Installation

Note: The recommended clearance is 1.5 inches above and below the device.
Caution: To avoid personal injury or damage to the device, it is recommended that two or more people mount the device on a rack.

Front FS-624F /-FPOE

FORTINET-FS-624F-FortiSwitch- \(8\)

  1. Ports 1 to 32 (RJ45)4FORTINET-FS-624F-FortiSwitch- 1
  2. Ports 33 to 48 (RJ45)
  3. Ports 49 to 56 (SFP28
  4. Ports 33 to 48 (RJ45) FORTINET-FS-624F-FortiSwitch- \(11\)01

Rear FS-624F /-FPOE FORTINET-FS-624F-FortiSwitch-
\(10\)

  1. PPS IN/OUT (SMB) Pulse per second synchronization ports
  2. Redundant Power Supplies (System Rated per PSU)
    FS-624F: 100-240VAC, 3A Max, 50-60Hz
    FS-624F-FPOE: 100-127VAC, 12A Max or 200-240VAC, 6A Max, 50-60Hz

Front FS-648F /-FPOEFORTINET-FS-624F-FortiSwitch-
\(11\)

  1. Ports 1 to 32 (RJ45)
  2. Ports 33 to 48 (RJ45)
  3. Ports 49 to 56 (SFP28)
  4. PWR1
  5. MGMT (RJ45) default IP 192.168.1.99

Rear FS-648F /-FPOE FORTINET-FS-624F-FortiSwitch-
\(1\)

  1. PPS IN/OUT (SMB) Pulse per second synchronization ports
  2. Redundant Power Supplies (System Rated per PSU)
    FS-648F: 100-240VAC, 3A Max, 50-60Hz
    FS-648F-FPOE: 100-127VAC, 12A Max or 200-240VAC, 6A Max, 50-60Hz

Cautions and Warnings

Environmental specifications
Ambient operating temperature: 0°C to 45°C
Rack Mount Instructions – The following or similar rack-mount instructions are included with the installation instructions:

Instructions de montage en rack – Les instructions de montage en rack suivantes ou similaires sont incluses avec les instructions d’installation:
Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

Circuit Overloading – Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)

Safety
Battery – Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. They may explode. Dispose of used batteries according to your local regulations. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.

CAUTION:

  • There is a danger of explosion if a battery is incorrect replaced. Replace only with the same or equivalent type.
  • Dispose batteries of according to the manufacturer’s instructions.
  • Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion.
  • Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion.
  • If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.

WARNUNG:
CAUTION: Shock Hazard. Disconnect all power sources.
Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning / surge protector, and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap while you work. In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing.
This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size # 14 AWG and the connection is to be installed by a qualified service personnel.

Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space.

Warning: Stability hazard.

  • The rack may tip over causing serious personal injury.
  • Before extending the rack to the installation position, read the installation instructions.
  • Do not put any load on the slide-rail-mounted equipment in the installation position.
  • Do not leave the slide-rail-mounted equipment in the installation position.
  • IEC 60825-1:2014 transfer to FDA/CDRH Complies with FDA performance standards for laser products except for conformance with IEC 60825-1 Ed.3., as described in Laser Notice No. 56, dated May 8, 2019.
  • The SFP ports should use UL Listed Optional Transceiver product, Rated 3.3Vdc, Laser Class 1.
  • Fiber optic transceiver must be rated 3.3V, 22mA max, Laser Class 1, UL certified component.
  • This product is intended to be supplied by means of a power cord connected to a socket outlet with earthing connection.

Warning: Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltage on accessible metal parts.

Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
    this device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

WARNING: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada
CAN ICES-003 (A) / NMB-003 (A)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

European Conformity (CE) – EU
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Voluntary Control Council for Interference (VCCI) – Japan
Product Safety Electrical Appliance & Material (PSE) – Japan
Bureau of Standards Metrology and Inspection (BSMI) – Taiwan
The presence conditions of the restricted substance (BSMI RoHS table) are available at the link below:

Fortinet.com

July 27, 2023 This guide covers models: FS-624F, FS-624F-FPOE, FS-648F, FS- 648F-FPOE Copyright® 2023 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s General Counsel, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward-looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable. For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals