ecler eMWR Essentials Wireless Microphone System User Guide

June 3, 2024
ecler

ecler LOGO Ecler Essentials Wireless Microphone System
eMWR/eMWH/eMWE
QUICK GUIDEecler eMWR Essentials Wireless Microphone
System

eMWR Essentials Wireless Microphone System

IMPORTANT NOTE
Thank you for having chosen our Ecler Essentials Wireless Microphone System.
In order to get the optimum operation and efficiency from your product, it is VERY IMPORTANT – before you plug anything – to read this manual very carefully and take seriously into account all considerations specified within it.
We strongly recommend that its maintenance be carried out by our Authorised Technical Services.
Compliance with international standards
The Ecler Essentials Wireless Microphone System complies with the following international standards:

  • EN55103-1 Electromagnetic Compatibility.
    Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use
    Part 1: Emission

  • EN55103-2 Electromagnetic Compatibility.
    Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use
    Part 2: Immunity

  • EN60065 Audio, video and similar electronic apparatus. Safety requirements Complying with the requirements of directives 73/23/EC and 2004/108/EC

eMWR: WIRELESS UHF MICROPHONE RECEIVER

| ecler eMWR Essentials Wireless Microphone System - FIGURE
2
---|---
1. Volume control
2. LCD display
3. Infrared receiver
4. UP Button
5. SET button
6. DOWN Button
7. POWER button
8. DC POWER socket
9. Antenna B input socket
10. Balanced XLR audio output
11. Unbalanced Jack audio output
12. Output Level selection switch
13. Antenna A input socket| 1. 8-STEP level display (RF signal)
2. 8-STEP level display (AF signal)
3. Frequency menu display
4. Channel menu display
5. 6-character alphanumeric display
6. Diversity display (active antenna)
7. MUTE display

Operation

  1. Adjust the volume to its minimum before turning on the transmitter. Then turn on the receiver. LCD display will show the channel/frequency of the receiver. Press UP/DOWN button to select the desired channel/frequency and press SET to confirm changes.
  2. If a RF and/or AF strong level appears when the transmitter is off, change the channel in the receiver to avoid interferences.
  3. Turn on the transmitter. RF level meter shows the intensity of the received signal meanwhile AF meter shows its audio amplitude. Adjust the volume according AF level meter. Check that transmitter and receiver are in the same channel/frequency.
  4. To link receiver and transmitter by means of an infrared signal, between emitter and receiver, press SET button, the display will show PRG IR and after 2-3 seconds the receiver will automatically link with the transmitter.
  5. Press the POWER button for 2 or 3 seconds to turn off the receiver.
  • Keys functions:
    • SET: menu selection and settings confirmation.
    • UP & DOWN: parameters selection in the current menu. Hold for quick frequency and channel selection.
  • Menus:
    • CHANNEL/FREQUENCY: allows selecting the channel/frequency.
    • PRG IR: allows linking receiver-transmitter by means of infrared frequency.
    • SQUELCH: when the received signal strength falls below this threshold, the output of the receiver is muted.
    • DISPL: channel/frequency display.
    • LOCK: LOCK ON mode prevents to accidentally change current work status. LOCK OFF mode restores usual operation.

eMWH: HANDHELD UHF WIRELESS TRANSMITTER


1. Channel display
2. 6-character alphanumeric display
3. Battery status| 1. Grille
2. Body
3. LCD display
4. POWER button
5. LOCK switch
6. Infrared receiver (IR)
7. RF signal
8. Tail cover
9. Battery tray

Operation

  1. Click the power on button. LCD display will show current channel.
  2. To change the channel, first select the channel/frequency on the receiver. Then, facing IR receiver of the microphone with IR transmitter on the eMWR, press SET button to link both devices.

eMWH: BELTPACK UHF WIRELESS TRANSMITTER

ecler eMWR Essentials Wireless Microphone System - FIGURE
4

  1. Microphone/line input
  2. Power button
  3. Battery indicator
  4. Antenna
  5. Back splint
  6. LCD display
  7. SET button
  8. Battery tray
  9. Volume control
  10. Power control
  11. Infrared interface

Operation

  1. Switch on the power button. LCD display will show current channel.
  2. To change the channel, first select the channel/frequency on the receiver. Then, facing IR receiver of the belt-pack with IR transmitter on the eMWR, press SET button of the receiver to link both devices. Channel/frequency can be adjusted by means of SET/UP/DOWN buttons.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE
No operation indication Transmitter’s batteries are exhausted or DC in is not

well connected
No RF signal| Transmitter and receiver are not at the same channel
Transmitter is out of range
RF signal available, no audio signal, ”MUTE” appears on the display panel| Transmitter is muted
Receiver’s squelch threshold is adjusted too high
Transmitter doesn’t transmit a pilot tone
Audio signal has a high level of background noise| Transmitter sensitivity is adjusted too low
Receiver’s AF output level is adjusted too low
Audio signal is distorted| Transmitter sensitivity is adjusted too high
Receiver’s AF output level is adjusted too high
The use of short-distance, Signal instability| Transmitter set at a low-power
Squelch threshold is too high
Receiver antenna set improperly
Surrounded by strong electromagnetic interference

TECHNICAL SPECIFICATIONS

SYSTEM

Frequency range 823 – 832MHz
Modulation Mode Broadband FM
Available Bandwidth 50MHz
Number of channels 100
Channel spacing 250KHz
Frequency stability ±0.005%
Dynamic range 100dB
Peak deviation ±45KHz
Audio response 80Hz-18KHz(±3dB)
Comprehensive SNR >105 dB
Comprehensive Distortion ≤0.5%
Operating Temperature -10°C to +40°C

RECEIVER

Receive mode Double Conversion Super Heterodyne
Intermediate frequency The first medium frequency:100MHz

The second medium frequency:10.7MHz
Wireless interface| BNC /500Ω
Sensitivity| 12dBµV (80 dBS/N )
Spurious rejection| ≥75 dB
Sensitivity adjustment range| 12-32dBV
Maximum output level| + 10 dBV

TRANSMITTER

Output power High:30mW; Low:3mW
Spurious rejection -60dB
Voltage Two AA batteries
Current utility time High: >10 hours

Low: >15 hours
Number of parallel systems| 12

NEEC AUDIO BARCELONA S.L.
Motors 166­168, 08038 Barcelona, Spain
http://www.ecler.com
50.0306.01.00

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals