Power Technologies CNC-18TM Bay Charging Sanitizing Cabinet
Specifications
-
Model: CNC-18TM
-
Cabinet Dimensions: Inch 27.5 (H) x 29.6 (W) x 17 (D) cm 69.8 (H) x 75.2 (W) x 43.2 (D)
-
Interior Dimensions: Inch 19.25 (H) x 25 (W) x 16 (D); Device spacing: 1.18 cm 48.9 (H) x 63.5 (W) x 40.6 (D); Device spacing: 3
-
Product Weight (Without Devices): 100 lbs (45.35 kg)
-
Shipping Weight: 123 lbs (55.79 kg)
-
Capacity: 18 Laptops/Tablets – Configurable Interior
-
Supported Devices: Devices up to 14 Inch
-
Power Specifications (For Cabinets sold within North
America): AC IN/ Power Strip: 110V AC, 50/60Hz, 10A Maximum power: 1200W -
Power Specifications (For Cabinets sold outside North
America): AC IN/ Power Strip: 100-240V AC, 50/60Hz, 10A Maximum power: 2000W -
Charging Type: Basic Charging, 65 Watt USB-C Charging Hub
-
Security: Front door 3-point mechanism with key lock
-
Sanitize Type: UV-C Light Sanitization
-
Bulb Specification: Bulb Wattage: 16 Watts, Bulb Life: more than 6000 hours
-
Working Temperature: 10% – 90% RH
-
Storage Temperature: 5% – 95% RH
-
Warranty: Lifetime Frame, 2 Years Components, 2 Year Electronics
Product Usage Instructions
Charging and Sanitizing Devices
- Ensure the cabinet is plugged into a power source according to the specifications for your region.
- Open the front door using the key lock mechanism.
- Place devices inside the cabinet with appropriate spacing as indicated in the interior dimensions.
- Connect the devices to the charging hub provided.
- Close the door and activate the UV-C light sanitization feature if desired.
Frequently Asked Questions (FAQ):
Q: What devices are supported by the CNC-18TM?
A: The CNC-18TM supports devices up to 14 inches, including Chromebooks,
Laptops, and tablets.
CNC-18™
18 BAY CHARGING & UV-C SANITIZING CABINET
USER MANUAL
Product Information
Designed to charge, securely store and sanitize 18 devices upto 14 inches.
Specifications
Model | CNC-18™ |
---|---|
Cabinet Dimensions | Inch |
cm | 69.8 (H) x 75.2 (W) x 43.2 (D) |
**Interior Dimensions** | Inch |
spacing: 1.18
cm| 48.9 (H) x 63.5 (W) x 40.6 (D); Device spacing: 3
Product weight
(Without Devices)| 100 lbs (45.35 kg)
Shipping Weight| 123 lbs (55.79 kg)
Capacity| 18 Laptops/Tablets – Configurable Interior
Supported Devices| Devices up to 14 Inch
Power Specifications
(For Cabinets sold within North America)| AC IN/ Power Strip: 110V AC,
50/60Hz, 10A Maximum power: 1200W
Power Specifications
( For Cabinets sold outside North America)| AC IN/ Power Strip:
100-240V AC, 50/60Hz, 10A
Maximum power: 2000W
Charging Type| Basic Charging, 65 Watt USB-C Charging Hub
Security| Front door 3-point mechanism with key lock
Sanitize Type| UV-C Light Sanitization
Bulb Specification| 360° reach – 8 lamps & reflective lining Virtually
Eliminate Blind Spots, mercury based bulb
Bulb Wattage| 16 Watts
Bulb Life| more then 6000 hours
Adapter Shelves Loading (ea.)| 6.6 lbs (3 kg)
Working Temperature| 0°- 30°c
Working RH%| 10% – 90%
Storage Temperature| -40°- 60°C Temp
Storage RH%| 5% – 95%
Warranty| Lifetime Frame, 2 Years Components, 2 Year Electronics
This manual covers the following models and part numbers.
The manual is based upon the North American 110V product offering.
Refer to the part numbers below and cord end diagrams for your specific
region.
MODEL# CNC-18™
SKU | DESCRIPTION |
---|---|
CAB-CNC-B18K-D | AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 110V NA |
CAB-CNC-B18K-E | AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V EU |
CAB-CNC-B18K-U | AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V UK |
CAB-CNC-B18K-A | AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V AU |
CAB-CNC-B18K-S | AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V SW |
Power Cords and Sockets for Specific Region
The CNC-18™ is designed to charge
store & disinfects up to 99.9% of bacteria from Chromebooks, Laptops, tablets.
NOTE: Please review this guide before installing devices and to learn how to
safely use your cart.
- If the device (Laptop / Chromebook) thickness is more than the gap between the SS racks, adjust SS racks to create enough space for your device.
- Removable and lockable top panel area is used to place power adapters.
User Instructions
Operation and User Interface
- Using the CNC-18 is very simple; unlock door and load the device into the cabinet, plug device it it’s a pre-loaded charging cable.
- CNC-18 will charge the device based upon device’s settings. Once charged CNC-18 provides a maintenance charge keeping devices ready for use.
- Unlock and lock the cabinet via the control panel. Cabinet is equipped with an electro-magnetic lock that engages while the unit is powered. A mechanical key lock is available for additional security and administrative use.
- Press Lock Icon to lock and unlock the door. Cabinet door will not unlock during UV-C disinfection. Press stop to end UV-C disinfection to activate the lock button
UV-C bulb life is monitored by the bulb life countdown meter. Press the “bulb” icon to see the number of hours bulb has been in use.
Care and Maintenance
- Keep the cabinet exterior clean with a mild cleaner on a soft cloth for exterior surfaces.
- Interior service should be cleaned via compressed air once a month or as needed.
- Medical grade stainless steel racks should be wiped down with mild cleaner once a month or as needed.
- UV-C bulb has a bulb life count down feature on the control panel and bulbs should be replaced around the 10 hour mark.
Determining Time
The germicidal properties of the (8) 254 nm UV-C bulbs used in the CNC-18™ are
documented to provide up to 4-log (99.99%) disinfection with just 2 minutes of
exposure time.
Additional time settings may be used for other organisms not listed.
The following list is provided as a guide of which organisms become
deactivated within 2 minutes:
Note: This UV-C product is not approved and/or certified as a medical device.
Installation Instructions
Accessing Charging hub and wiring for your devices
Fitting Devices Inside Cabinet
SETTING UP DEVICES:
- Step-1: Open the door
- Step-2: If your devices are less than 7.25” wide, place them directly onto the shelves.
- Step-3: If your devices are more than 7.25” wide, remove the thumbscrews from the left/right sides and pull the center shelf out.
- Step-4: Place devices so that all surfaces are completely exposed.
- Step-5: If needed, place less items inside to avoid crowding.
- Step-6: Begin Disinfection process
Disinfecting Of Devices
Disinfect and charge laptops, tablets, and other electronic devices.
Overview:
Support infection control initiatives with ultraviolet (UV-C) light
sanitization to encourage more frequent disinfection without the use of
corrosive chemicals. CNC-18™ effectively kills 99.9% of infectious pathogens
from laptops, tablets, headphones, VR headsets, and other electronic devices.
The UV absorbing, transparent window with electro-magnetic locking system
keeps users safe while devices are being disinfected. Disinfection cycle
times, from 2 minutes to 20 minutes, can be customized depending on workflow
and efficacy needs.
CNC-18™ customizable charging for up to 18 electronic devices. Designed with
the highest level of flexibility and versatility in mind,
CNC-18™ offers the ability to configure medical grade stainless steel racks to
adapt to devices of varying shapes and sizes. Integrated cable management and
lockable power adapter storage area keep cables organized and secure.
Disinfect
- Medical Grade Stainless Steel Racks.
- Chemical-free UV- surface disinfection process.
- Sanitizes Exposed Surfaces.
- Locker Power Adapter Storage Area with Removable Top Panel.
- Effectively kill 99.9% of infectious pathogens like influenza, the common cold and coronavirus.
- 360° reach – eight lamps & reflective lining Virtually Eliminate Blind Spots.
- Customizable disinfection cycle times.
- Integrated Cable Management.
Bulb Life & Replacement
CAUTION: UV Lamps contain mercury – manage in accordance with your local
disposal laws. A lamp breaking is extremely unlikely to have any impact on
your health. If a lamp breaks, ventilate the room for 30 minutes and remove
the parts, preferably with gloves. Put them in a sealed plastic bag and take
it to your local waste facilities for recycling. Do not use a vacuum cleaner.
For maximum efficiency, change bulbs when one no longer works or more than
6,000 hours.
- Step-1: With your unit unplugged from an electrical outlet, open the door.
- Step-2: Remove the thumbscrews from the left side and pull the upper, middle & lower shelves out.
- Step-3: Wearing cotton gloves, rotate the old bulb counter clockwise to release it from the lamp socket. Install new bulb by placing into lamp socket and rotating clockwise until you hear a click.
- Step-4: Plug the unit back into an electrical outlet and reset the Bulb Use Hours counter by pressing “Bulb Use” for 6 seconds. Then, enter “0 – 3 – 1 – 4” when prompted.
Safety Instructions
- ALWAYS move the cabine slowly and be aware of our surroundings.
- Used or broken bulbs should be disposed of in accordance with all applicable disposal laws.
- Repairs should always be performed by a qualified electrician.
- Set the power switch to the OFF position before you unplug the unit from the wall, plug the unit into the wall, or plug in devices.
- Do not touch bulbs or ballasts.
- Do not alter the construction or design. Do not remove safety labels or devices.
- Do not use this product around flammable or combustible materials.
Troubleshooting
If one or more bulbs is not working, follow these steps before replacing:
- Step-1: With your unit unplugged from an electrical outlet, open the door.
- Step-2: If your devices are less than 7.25” wide, place them directly onto the shelves.
- Step-3: If your devices are more than 7.25” wide, remove the thumbscrews from the left/right sides and pull the center shelf out.
- Step-4: Place devices so that all surfaces are completely exposed.
- Step-5: If needed, place less items inside to avoid crowding.
- Step-6: Begin Disinfection process
Further Information
For further information on this product and others, contact Power Technologies
at.
Power Technologies
42035 Zevo Dr
Temecula, CA 92590+
888.650.4488
support@powertechnologies.com
www.powertechnologies.com
42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>