Power Technologies CNC-18TM Bay Charging Sanitizing Cabinet Installation Guide

July 14, 2024
Power Technologies

Power Technologies CNC-18TM Bay Charging Sanitizing Cabinet

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
PRODUCT

Specifications

  • Model: CNC-18TM

  • Cabinet Dimensions: Inch 27.5 (H) x 29.6 (W) x 17 (D) cm 69.8 (H) x 75.2 (W) x 43.2 (D)

  • Interior Dimensions: Inch 19.25 (H) x 25 (W) x 16 (D); Device spacing: 1.18 cm 48.9 (H) x 63.5 (W) x 40.6 (D); Device spacing: 3

  • Product Weight (Without Devices): 100 lbs (45.35 kg)

  • Shipping Weight: 123 lbs (55.79 kg)

  • Capacity: 18 Laptops/Tablets – Configurable Interior

  • Supported Devices: Devices up to 14 Inch

  • Power Specifications (For Cabinets sold within North
    America):
    AC IN/ Power Strip: 110V AC, 50/60Hz, 10A Maximum power: 1200W

  • Power Specifications (For Cabinets sold outside North
    America):
    AC IN/ Power Strip: 100-240V AC, 50/60Hz, 10A Maximum power: 2000W

  • Charging Type: Basic Charging, 65 Watt USB-C Charging Hub

  • Security: Front door 3-point mechanism with key lock

  • Sanitize Type: UV-C Light Sanitization

  • Bulb Specification: Bulb Wattage: 16 Watts, Bulb Life: more than 6000 hours

  • Working Temperature: 10% – 90% RH

  • Storage Temperature: 5% – 95% RH

  • Warranty: Lifetime Frame, 2 Years Components, 2 Year Electronics

Product Usage Instructions
Charging and Sanitizing Devices

  1. Ensure the cabinet is plugged into a power source according to the specifications for your region.
  2. Open the front door using the key lock mechanism.
  3. Place devices inside the cabinet with appropriate spacing as indicated in the interior dimensions.
  4. Connect the devices to the charging hub provided.
  5. Close the door and activate the UV-C light sanitization feature if desired.

Frequently Asked Questions (FAQ):
Q: What devices are supported by the CNC-18TM?
A: The CNC-18TM supports devices up to 14 inches, including Chromebooks, Laptops, and tablets.

CNC-18™
18 BAY CHARGING & UV-C SANITIZING CABINET
USER MANUAL

Product Information

Designed to charge, securely store and sanitize 18 devices upto 14 inches.

Specifications

Model CNC-18™
Cabinet Dimensions Inch
cm 69.8 (H) x 75.2 (W) x 43.2 (D)
**Interior Dimensions** Inch

spacing: 1.18
cm| 48.9 (H) x 63.5 (W) x 40.6 (D); Device spacing: 3
Product weight
(Without Devices)| 100 lbs (45.35 kg)
Shipping Weight| 123 lbs (55.79 kg)
Capacity| 18 Laptops/Tablets – Configurable Interior
Supported Devices| Devices up to 14 Inch
Power Specifications
(For Cabinets sold within North America)| AC IN/ Power Strip: 110V AC, 50/60Hz, 10A Maximum power: 1200W
Power Specifications
( For Cabinets sold outside North America)| AC IN/ Power Strip: 100-240V AC, 50/60Hz, 10A
Maximum power: 2000W
Charging Type| Basic Charging, 65 Watt USB-C Charging Hub
Security| Front door 3-point mechanism with key lock
Sanitize Type| UV-C Light Sanitization
Bulb Specification| 360° reach – 8 lamps & reflective lining Virtually Eliminate Blind Spots, mercury based bulb
Bulb Wattage| 16 Watts
Bulb Life| more then 6000 hours
Adapter Shelves Loading (ea.)| 6.6 lbs (3 kg)
Working Temperature| 0°- 30°c
Working RH%| 10% – 90%
Storage Temperature| -40°- 60°C Temp
Storage RH%| 5% – 95%
Warranty| Lifetime Frame, 2 Years Components, 2 Year Electronics

This manual covers the following models and part numbers.
The manual is based upon the North American 110V product offering.
Refer to the part numbers below and cord end diagrams for your specific region.

MODEL# CNC-18™

SKU DESCRIPTION
CAB-CNC-B18K-D AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 110V NA
CAB-CNC-B18K-E AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V EU
CAB-CNC-B18K-U AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V UK
CAB-CNC-B18K-A AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V AU
CAB-CNC-B18K-S AC-CNC-18, 18 Bay UV-C Sanitizing & charging Cabinet – 220V SW

Power Cords and Sockets for Specific Region

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
\(2\)The CNC-18™ is designed to charge store & disinfects up to 99.9% of bacteria from Chromebooks, Laptops, tablets.
NOTE: Please review this guide before installing devices and to learn how to safely use your cart.

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
\(3\)

  • If the device (Laptop / Chromebook) thickness is more than the gap between the SS racks, adjust SS racks to create enough space for your device. Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(4\)
  • Removable and lockable top panel area is used to place power adapters. Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(5\)

User Instructions

Operation and User Interface

  • Using the CNC-18 is very simple; unlock door and load the device into the cabinet, plug device it it’s a pre-loaded charging cable.
  • CNC-18 will charge the device based upon device’s settings. Once charged CNC-18 provides a maintenance charge keeping devices ready for use.
  • Unlock and lock the cabinet via the control panel. Cabinet is equipped with an electro-magnetic lock that engages while the unit is powered. A mechanical key lock is available for additional security and administrative use.
  • Press Lock Icon to lock and unlock the door. Cabinet door will not unlock during UV-C disinfection. Press stop to end UV-C disinfection to activate the lock button Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(6\)

UV-C bulb life is monitored by the bulb life countdown meter. Press the “bulb” icon to see the number of hours bulb has been in use.

Care and Maintenance

  • Keep the cabinet exterior clean with a mild cleaner on a soft cloth for exterior surfaces.
  • Interior service should be cleaned via compressed air once a month or as needed.
  • Medical grade stainless steel racks should be wiped down with mild cleaner once a month or as needed.
  • UV-C bulb has a bulb life count down feature on the control panel and bulbs should be replaced around the 10 hour mark.Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(7\)

Determining Time

The germicidal properties of the (8) 254 nm UV-C bulbs used in the CNC-18™ are documented to provide up to 4-log (99.99%) disinfection with just 2 minutes of exposure time.
Additional time settings may be used for other organisms not listed.
The following list is provided as a guide of which organisms become deactivated within 2 minutes:

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
\(8\)

Note: This UV-C product is not approved and/or certified as a medical device.

Installation Instructions

Accessing Charging hub and wiring for your devices Power-Technologies-CNC-
18TM-Bay Charging-Sanitizing-Cabinet- \(9\)

Fitting Devices Inside Cabinet

SETTING UP DEVICES:

  1. Step-1: Open the door
  2. Step-2: If your devices are less than 7.25” wide, place them directly onto the shelves. Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(9\)
  3. Step-3: If your devices are more than 7.25” wide, remove the thumbscrews from the left/right sides and pull the center shelf out.
  4. Step-4: Place devices so that all surfaces are completely exposed. Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(11\)
  5. Step-5: If needed, place less items inside to avoid crowding.
  6. Step-6: Begin Disinfection processPower-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(12\)

Disinfecting Of Devices

Disinfect and charge laptops, tablets, and other electronic devices.

Overview:
Support infection control initiatives with ultraviolet (UV-C) light sanitization to encourage more frequent disinfection without the use of corrosive chemicals. CNC-18™ effectively kills 99.9% of infectious pathogens from laptops, tablets, headphones, VR headsets, and other electronic devices. The UV absorbing, transparent window with electro-magnetic locking system keeps users safe while devices are being disinfected. Disinfection cycle times, from 2 minutes to 20 minutes, can be customized depending on workflow and efficacy needs.
CNC-18™ customizable charging for up to 18 electronic devices. Designed with the highest level of flexibility and versatility in mind,
CNC-18™ offers the ability to configure medical grade stainless steel racks to adapt to devices of varying shapes and sizes. Integrated cable management and lockable power adapter storage area keep cables organized and secure.

Disinfect

  • Medical Grade Stainless Steel Racks.
  • Chemical-free UV- surface disinfection process.
  • Sanitizes Exposed Surfaces.
  • Locker Power Adapter Storage Area with Removable Top Panel.
  • Effectively kill 99.9% of infectious pathogens like influenza, the common cold and coronavirus.
  • 360° reach – eight lamps & reflective lining Virtually Eliminate Blind Spots.
  • Customizable disinfection cycle times.
  • Integrated Cable Management. Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(13\)

Bulb Life & Replacement

CAUTION: UV Lamps contain mercury – manage in accordance with your local disposal laws. A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a vacuum cleaner.
For maximum efficiency, change bulbs when one no longer works or more than 6,000 hours.

  1. Step-1: With your unit unplugged from an electrical outlet, open the door.
  2. Step-2: Remove the thumbscrews from the left side and pull the upper, middle & lower shelves out.Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(14\)
  3. Step-3: Wearing cotton gloves, rotate the old bulb counter clockwise to release it from the lamp socket. Install new bulb by placing into lamp socket and rotating clockwise until you hear a click.
  4. Step-4: Plug the unit back into an electrical outlet and reset the Bulb Use Hours counter by pressing “Bulb Use” for 6 seconds. Then, enter “0 – 3 – 1 – 4” when prompted.

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
\(15\)

Safety Instructions

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
\(16\)

  • ALWAYS move the cabine slowly and be aware of our surroundings.
  • Used or broken bulbs should be disposed of in accordance with all applicable disposal laws.
  • Repairs should always be performed by a qualified electrician.
  • Set the power switch to the OFF position before you unplug the unit from the wall, plug the unit into the wall, or plug in devices.
  • Do not touch bulbs or ballasts.
  • Do not alter the construction or design. Do not remove safety labels or devices.
  • Do not use this product around flammable or combustible materials.

Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet-
\(17\)

Troubleshooting

If one or more bulbs is not working, follow these steps before replacing:

  1. Step-1: With your unit unplugged from an electrical outlet, open the door.
  2. Step-2: If your devices are less than 7.25” wide, place them directly onto the shelves.Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(18\)
  3. Step-3: If your devices are more than 7.25” wide, remove the thumbscrews from the left/right sides and pull the center shelf out.
  4. Step-4: Place devices so that all surfaces are completely exposed. Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(19\)
  5. Step-5: If needed, place less items inside to avoid crowding.
  6. Step-6: Begin Disinfection process Power-Technologies-CNC-18TM-Bay Charging-Sanitizing-Cabinet- \(1\)

Further Information

For further information on this product and others, contact Power Technologies at.
Power Technologies
42035 Zevo Dr
Temecula, CA 92590+
888.650.4488
support@powertechnologies.com
www.powertechnologies.com

42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals