21 Installation, Operation and Maintenance
W561 WiFi Thermostat

W561 WiFi Thermostat

WATTS W561 WiFi Thermostat - fig 1

Compatible With

  • 1-stage heating
  • Supports included floor sensor for radiant floor heating applications.

WARNING
Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure.
Keep this Manual for future reference.
The App Store® is a registered trademark of Apple Inc.
The “Google Play” name and the Google Play Store icon are property of Google LLC.

Important Safety Information

It is your responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards. Watts® is not responsible for damages resulting from improper installation and/or maintenance.
This is a safety-alert symbol. The safety alert symbol is shown alone or used with a signal word (DANGER, WARNING, or CAUTION), a pictorial and/or a safety message to identify hazards.
When you see this symbol alone or with a signal word on your equipment or in this Manual, be alert to the potential for death or serious personal injury.
This pictorial alerts you to electricity, electrocution, and shock hazards.
This symbol identifies hazards which, if not avoided, could result in death or serious injury.
This symbol identifies hazards which, if not avoided, could result in minor or moderate injury.
Note This symbol identifies practices, actions, or failure to act which could result in property damage or damage to the equipment.
Read Manual and all product labels BEFORE using the equipment. Do not use unless you know the safe and proper operation of this equipment. Keep this Manual available for easy access by all users. Replacement Manuals are available at Watts.com

  • It is the installer’s responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards.
  • Improper installation and operation of this thermostat could result in damage to the equipment and possibly even personal injury or death.
  • This thermostat is not intended for use as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit.

NOTICE Do not attempt to service the thermostat. There are no user serviceable parts inside the thermostat. Attempting to do so voids warranty.

Installation

Preparation
Tools Required

  • Watts or jeweler screwdriver
  • Phillips head screwdriver
  • Wire stripper
  • Drill (for wall anchor)
  • 3⁄16″ drill bit (for wall anchor)

Installation Location
Materials Required

  • 18 AWG LVT Solid Wire (Low Voltage Connections)

WATTS W561 WiFi Thermostat - fig 3

NOTICE
Consider the following:

  • Interior Wall.
  • Keep dry. Avoid potential leakage onto the control.
  • Relative Humidity less than 90%. Non-condensing environment.
  • No exposure to extreme temperatures beyond 32-122°F (0-50°C).
  • No draft, direct sun, or other cause for inaccurate temperature readings.
  • Away from equipment, appliances, or other sources of electrical interference.
  • Easy access for wiring, viewing, and adjusting the display screen.
  • Approximately 5 feet (1.5 m) off the finished floor.
  • The maximum length of wire is 500 feet (150 m).
  • Strip wire to 3⁄8″ (10 mm) for all terminal connections.
  • Use standard 8 conductor, 18 AWG wire.

Removing the Thermostat Base
While holding the base section in one hand, pull the lower half of the display front towards you to pivot it away from the base.
WATTS W561 WiFi Thermostat - fig 4 Mounting the Thermostat
To prevent the risk of personal injury and/or death, make sure power is not applied to the thermostat until it is fully installed and ready for final testing. All work must be done with power to the circuit being worked on turned off.
Please be aware local codes may require this thermostat to be installed or connected by an electrician.
WATTS W561 WiFi Thermostat - fig 5 Application W561-1
The W561 WiFi Thermostat operates a radiant floor heating system. The thermostat uses the built-in air temperature sensor.
Mechanical
Legend
B1 = Boiler
BP = Boiler Pump
PS = System Pump
T1 = W561 WiFi Thermostat
V1 = Zone Valve
ZVC1 = Zone Valve Control 304V or 306V
WATTS W561 WiFi Thermostat - fig 6 ElectricalWATTS W561 WiFi Thermostat - fig 7 Application W561-2
The W561 WiFi Thermostat operates a radiant floor heating system based upon the floor temperature sensor, included. The built-in air sensor is disabled.
Mechanical
Legend
B1 = Boiler
BP = Boiler Pump
PS = System Pump
T1 = W561 WiFi Thermostat
S1 = Floor Sensor 079
V1 = Zone Valve
ZVC1 = Zone Valve Control 304V or 306V
WATTS W561 WiFi Thermostat - fig 8 ElectricalWATTS W561 WiFi Thermostat - fig 9 Application W561-3
The W561 WiFi Thermostat operates a radiant floor heating system. The thermostat uses both air and floor temperature sensors. The air temperature sensor can be either built-in and/or external.
Mechanical
Legend
B1 = Boiler
BP = Boiler Pump
PS = System Pump
T1 = W561 WiFi Thermostat
S1 = Floor Sensor 079
S2 = Optional Indoor Sensor 084
V1 = Zone Valve
ZVC1 = Zone Valve Control 304V or 306VWATTS W561 WiFi Thermostat - fig
10 ElectricalWATTS W561 WiFi Thermostat - fig
11 Application W561-4
The W561 WiFi Thermostat operates a baseboard/radiator using an air temperature sensor. The air temperature sensor can be either built-in and/or external.
Mechanical
Legend
B1 = Boiler
BP = Boiler Pump
PS = System Pump
T1 = W561 WiFi Thermostat
S1 = Optional Indoor Sensor 084
V1 = Zone Valve
ZVC1 = Zone Valve Control 304V or 306V
WATTS W561 WiFi Thermostat - fig 12 Electrical
WATTS W561 WiFi Thermostat - fig 13

Sequence of Operation

Heating Operation
The heating setpoint can be set from 40 to 95°F (4.5 to 35°C). The Heat On symbol is shown on the display when the thermostat is heating. Heating for freeze protection is provided whenever the air or floor temperature falls below 40°F (4.5°C), regardless of operating mode.
Regular Heating
W1 relay is on when the air temperature falls 1.5°F (1°C) below the Heat To setting.
When the temperature reaches the Heat To setting, the relay turns off.
Radiant Floor Heating
When Radiant Floor Heating is selected in the setup menu, the W1 relay operates using Pulse Width Modulation. This improves comfort for radiant systems with high mass floors.

  • 100% on time at Heat To setting -1.5°F
  • 50% on time at Heat To setting
  • 0% on time at Heat To setting + 1.5°F

Room Sensor and Averaging
The thermostat can measure room temperature between -46 to 212°F (-43 to 100°C).
The room temperature can be measured using a combination of the built-in and auxiliary sensors.

  • Built-in room sensor only
  • Built-in room sensor with auxiliary room sensor(s) (temperature is averaged)
  • Auxiliary room sensor only

Floor Sensor for Radiant Floor Heating
The thermostat can measure floor temperature between -46 to 212°F (-43 to 100°C).
If a floor sensor is connected, floor minimum and maximum settings are available.
The floor heating setpoint is adjustable from 40 to 100°F (4.5 to 38.0°C).
For a combination of air and floor temperature control, leave the internal air sensor on in the setup menu. A floor minimum can be used to prevent a fast drop in temperature caused by receding solar exposure. This operation is recommended for areas heated by afternoon sun through large windows. When the sun sets, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room.
A floor maximum is recommended for rooms with hardwood floors. Setting floor minimum and maximum temperatures is a way of enhancing the comfort of the living space while protecting floor coverings.
If there are more than one floor temperature sensors, the temperature is averaged.
Warm Weather Shut Down (WWSD)
The heating system can automatically shut off based upon the outdoor temperature and the WWSD setting. This provides a convenient way to shut off radiant floor heating.

User Interface

After 60 seconds of inactivity, the thermostat home screen displays only the time and the temperature.WATTS W561 WiFi Thermostat - fig
14

User Settings

Away
Use the Away setting to save energy when the building is unoccupiedWATTS
W561 WiFi Thermostat - fig 15

  • Selecting the Away setting on a thermostat or the mobile app will affect all devices linked to that location through the app.
  • The Away temperature can be adjusted in the Setup /Temps menu.

ScheduleWATTS W561 WiFi Thermostat - fig 16

Display

Setting| Range|

Default

---|---|---
TEMPERATURE UNITS
Select °F or °C.| °F or °C| °F
ENERGY USE
View the number of hours the heating or cooling has operated either daily or monthly.| 0 to 24 (daily) 0 to 744 (monthly)| 0 hours

WATTS W561 WiFi Thermostat - fig 17

Setting| Range|

Default

---|---|---
BRIGHTNESS ACTIVE
Select the brightness when touching the screen.| 30 to 100%| 100%
BRIGHTNESS INACTIVE
Select the brightness when not in use.| Off, 30 to 100%| 50%
BACKGROUND
Select the background color.| Light, Blue, Night, Latte, Espresso| Blue
LANGUAGE
Select the language.| English, Español, Français| English
SCREEN CLEAN
Locks screen for 10 seconds to allow cleaning.| N/A| N/A
INACTIVE TIME DISPLAY
Select if the time is visible when the display is inactive.| Off or On| On
INACTIVE OUTDOOR DISPLAY
Select if the outdoor temperature is visible when the display is inactive.| Off or On| Off

TimeWATTS W561 WiFi Thermostat - fig 18

Setting| Range|

Default

---|---|---
TIME FORMAT
Select the time format.| 12 or 24 hour| 12 hour
TIME SOURCE
If Internet is available, the time source can be either  automatically or manually set.| Automatic, Manual| Auto
TIME ZONE
Select the local time zone.| Hawaii, Alaska, Pacific, Mountain, Central, Eastern, Atlantic, Newfoundland| Eastern
DAYLIGHT SAVING TIME
Select the brightness when not in use.| Off, On| On

NOTICE Incorrectly setting the time and date manually may prevent the thermostat from communicating to the mobile app. Automatic time source is recommended when using an Internet connection.
WiFi
NOTICE   Before using the WiFi features of this product, you must accept the Terms of Use, as amended from time to time and available at Watts.com /terms-of-use. If you do not accept these terms, this product can still be used without WiFi features.
The thermostat includes a step by step tutorial to setup the WiFi connection.
WATTS W561 WiFi Thermostat - fig 19

WiFi and Connectivity Troubleshooting

WiFi Connection Status
Press COG > WiFi > WiFi:On > CIRCLE-INFO to view the thermostat connection status.WATTS W561 WiFi Thermostat - fig 20

(1) WiFi Signal Strength
• The WiFi signal must measure between 0 and -69 dB to have a reliable connection to the Watts ®cloud.
• A WiFi extender is recommended to be installed if the WiFi signal is between -70 to -100 dB.
(2) Internet Connected
• The WiFi information screen will show Internet Connected when the thermostat is connected to the router and there is a connection to the Internet.
(3) IoT Connected
• The thermostat connection status will show IoT Connected when connected to the Watts Cloud and the thermostat is ready to be registered to the app.
If IoT is not connected, please follow these steps:
Check Password

  • Double check that you are using the correct WiFi network and password.
  • The password is limited to 32 characters, and can include upper and lower case letters, numbers, special characters and spaces. A space counts as a character.
  • The thermostat supports WPA2-Personal password security.

Power Off and On

  • Power the thermostat off. Next, power the router off, wait 10 seconds, then power on and wait for the Internet status to be on. Then power the thermostat on.

Check Router & Firewall
Consult the router manual or Internet
Service Provider (ISP) for assistance with router setup with these configurations:

  • The router must provide a 2.4 GHz signal. The thermostat is not compatible with 5 GHz networks.
  • The router is using WPA2-Personal security.
  • The router has DHCP enabled with enough available addresses for all Internet devices.
  • The router firewall is not blocking the outbound UDP or TCP ports: 53, 123, 443, 8883.
  • The router firewall is not blocking connections to *.azure-devices.net
  • The router firewall is not blocking the thermostat based upon a MAC filter list.

Network Troubleshooting

  • tekmar provides free access to a network troubleshooting tool called RouteThis Helps.
  • Download the app from the App Store or Google Play Store to your mobile device.
  • Enter code “TEKM” and click “Network scan”.

The app will provide further instructions.
Create a WiFi Hotspot

  • If you are unable to connect to the WiFi network, try creating a WiFi Hotspot on your mobile device to bypass the router.

  • Apple® * iOS WiFi hotspot instructions https://support.apple.com/en-us/HT204023

  • Android™** WiFi hotspot instructions
    https://support.google.com/android/answer/9059108

  • If the thermostat displays IoT connected when using the WiFi Hotspot, please contact your Internet Service Provider (ISP) or IT professional for assistance with the router.

  • Apple and App Store are trademarks of Apple Inc.
    ** Google, Android and Google Play are trademarks of Google LLC.

Installer Settings

Setup
The Setup menu contains five sub-menus that determine how the thermostat operates.WATTS W561 WiFi Thermostat - fig 21 Setup – Toolbox

Setting| Range|

Default

---|---|---
ERROR
Displays any error messages.| N/A| N/A
ACCESS LEVEL
Select between user and installer access levels. User access level restricts access in the Setup Menu.| User, Installer| Installer
STATUS
The current status of warm weather shut down, cold weather shut down and each of the relays.| WWSD, W1| N/A
SOFTWARE VERSION
Display the software version.| J1249A| N/A
LOAD DEFAULTS
All settings are returned to factory defaults.| Yes, No| No
CALIBRATE TOUCHSCREEN
Recalibrate the screen after loading factory defaults.| N/A| N/A

Setup – Temp

Setting Range Default

Screen Page 1
FLOOR MIN – WAKE
Select the floor temperature while in the wake schedule. Applies when there is both a floor and an air sensor.|

Off, 40 to 95°F Off, 4.5 to 35.0°C

| Off
FLOOR MIN – LEAVE
Select the floor temperature while in the leave schedule. Applies when there is both a floor and an air sensor.|

Off, 40 to 95°F Off, 4.5 to 35.0°C

| Off
FLOOR MIN – RETURN
Select the floor temperature while in the return schedule. Applies when there is both a floor and an air sensor.|

Off, 40 to 95°F Off, 4.5 to 35.0°C

| Off
FLOOR MIN – SLEEP
Select the floor temperature while in the sleep schedule. Applies when there is both a floor and an air sensor.|

Off, 40 to 95°F Off, 4.5 to 35.0°C

| Off
FLOOR MIN – AWAY
Select the floor temperature while in away.
Applies when there is both a floor and an air sensor.| Off, 40 to 95°F Off, 4.5 to 35.0°C| Off
FLOOR MAX
Select the maximum floor temperature. This protects the floor covering from over heating. Applies when there is a floor sensor.|

Off, 40 to 100°F Off, 4.5 to 38.0°C

| Off
Screen Page 2
HEAT TO AWAY
Select the heating temperature when away.| Off, 40 to 95°F Off, 4.5 to 35.0°C| 62°F (16.5°C)
HEAT TO MIN LIMIT
Select the minimum heating temperature limit.| Off, 40 to 95°F Off, 4.5 to 35.0°C| Off
HEAT TO MAX LIMIT
Select the maximum heating temperature limit.| Off, 40 to 95°F Off, 4.5 to 35.0°C| Off
WARM WEATHER SHUT DOWN
Select the outdoor temperature at which the heating is shut off.| Off, 40 to 95°F Off, 4.5 to 35.0°C| Off

Setup – Sensors

Setting Range Default

SENSOR 1
Select the type of sensor connected to S1 and Com wiring terminals.| Off, Room, Floor| Off
SENSOR 2
Select the type of sensor connected to S2 and Com wiring terminals.| Off, Room, Floor, Outdoor| Off
INTERNAL ROOM SENSOR
Select if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room or floor sensor.| Off, On| On
ROOM OFFSET

Select if the internal room temperature sensor is on or off. Only available when Sensor 1 or 2 is set to read a room or floor sensor.

| Off, -5 to +5°F -3.0 to 3.0°C| Off
FLOOR OFFSET
Manual offset correction of the floor temperature measurement.| Off, -5 to +5°F -3.0 to 3.0°C| Off

Setup – Alerts

Setting Range Default

ROOM HOT WARNING
Sends an email notification if the room exceeds this temperature.| Off, 40 to 100°F Off, 4.5 to 38.0°C| Off
ROOM COLD WARNING
Sends an email notification if the room falls below this temperature.| Off, 40 to 100°F Off, 4.5 to 38.0°C| Off

Setup – Relays

Setting Range Default

RADIANT FLOOR HEATING
Select if the first stage W1 heats a radiant floor.| No, Yes| No

Error Messages

When an error occurs an email notification will be sent to the registered Watts Home mobile or account owner.
Description
INTERNET UNAVAILABLE
The thermostat has a WiFi connection to the router but is unable to communicate to the Internet. Steps to clear the error include: 1) power off and on the router, 2) power off and on the thermostat.
MEMORY ERROR
The thermostat memory settings are corrupted. To clear, load the factory defaults in the Toolbox menu. The thermostat will not operate any heating equipment while this error message is present.
INTERNAL ROOM SENSOR FAULT
Due to an open or short circuit, the thermostat is unable to read the internal room temperature sensor. If sensor 1 or 2 is set to room the thermostat continues to operate, otherwise operation stops.
The error cannot be field repaired. Contact your Watts sales representative for warranty or repair procedures.
SENSOR 1 FAULT
Due to an open or short circuit, the thermostat is unable to read the sensor wired to S1 and Com. The thermostat stops normal operation if sensor 1 is the only active room or floor sensor or if a floor maximum temperature has been set. Check the auxiliary sensor wire for short circuits according to the sensor installation manual.
It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears.
SENSOR 2 FAULT
Due to an open or short circuit, the thermostat is unable to read the sensor wired to S2 and Com. The thermostat stops normal operation if sensor 2 is the only active room or floor sensor or if a floor maximum temperature has been set.
Check the auxiliary sensor wire for short circuits according to the sensor installation manual. It may be necessary to replace the auxiliary sensor. Once the error has been corrected, the error message automatically clears.
ROOM HOT WARNING
The room temperature is above the Room Hot Warning setting in the Alerts menu. The warning will automatically clear once the room temperature falls below the setting.
ROOM COLD WARNING
The room temperature is below the Room Cold Warning setting in the Alerts menu. The warning will automatically clear once the room temperature rises above the setting.

Technical Data

W561 WiFi Thermostat One Stage Heat

Literature| Submittal, Installation and Operating Manual, User Manual, Job Record, Watts Home Manual
Control| Microprocessor control. This is not a safety (limit) control.
Packaged weight| 0.6 lb. (270 g)
Dimensions| 45⁄8″ H x 3″ W x 15⁄16″ D (118 x 76 x 24 mm)
Enclosure| White PVC plastic, NEMA Type 1
Approvals| Meets Class B: ICES & FCC Part 15
Ambient conditions| Indoor use only, 32 to 122°F (0 to 50°C), RH ≤90% non- condensing
Power supply| 15 to 30 V (ac/dc), 2 VA standby, Class 2
Relays| 30 V (ac/dc), 2 A, Class 2 circuits
Sensor| NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892
– Included| 079
– Optional| tekmar type # 070, 072, 073, 076, 077, 084
Communications| WiFi 802.11n, 2.4 GHz, WPA2 encryption
Mobile app| Apple iOS 12 or higher, Android 10 or higher

Hydronic System Electronic Controls and Thermostats Limited Warranty
Watts Regulator Co. (the Company) warrants its hydronic system electronic controls and thermostats (the Product) to be free from defects in materials and workmanship under normal usage for a period of one year from the documented date of installation of the Product. In the event of defects within the warranty period, the Company will replace the Product without charge. This remedy is the sole and exclusive remedy for breach of warranty. This warranty is transferable to subsequent owners.
Under this Limited Warranty, the Company will provide the following:
In order to make a claim, you must:
(a) Provide the Company with sufficient details relating to the nature of the defect, the installation, the history of operation, and any repairs that may have been made.
(b) At the Company’s discretion and at the owner’s expense, ship the Product to the Company or the Company’s local representative or distributor.
(c) Provide proof that the Product was installed in accordance with the applicable Product Installation Manual and any special written design or installation guidelines by the Company for this project.
(d) Provide proof that the Product was installed in accordance with the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), and all applicable local building and electrical codes.
(e) Provide a retail sales receipt or proof of purchase.
The following are not covered by this Limited Warranty:
(a) Any incidental or consequential damage, including inconvenience, loss of time or loss of income.
(b) Any labor or materials required to repair or replace the Product that are not authorized in writing by the Company.
(c) Any labor or materials required to remove, repair or replace materials other than the Products.
(d) Any freight or delivery costs related to the Product or any related electrical products.
The Company assumes no responsibility under this Limited Warranty for any damage to the Product caused by any trades people, visitors on the job site, or damage caused as a result of post-installation work. This Limited Warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the Products. The staff at the Company is available to answer any questions regarding the proper installation or application of the Product at this toll-free phone number: 800-276-2419 (USA/International) or 888-208-8927 (Canada). If you are ever in doubt about the correct installation procedure to follow, or if the Product appears to be damaged, you must call us before proceeding with the installation or proposed repair.
THE COMPANY DISCLAIMS ANY WARRANTY NOT PROVIDED HEREIN, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. THE COMPANY FURTHER DISCLAIMS ANY RESPONSIBILITY FOR SPECIAL, INDIRECT, SECONDARY, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR USE OF THIS PRODUCT, INCLUDING INCONVENIENCE OR LOSS OF USE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE FACE OF THIS DOCUMENT. NO AGENT OR REPRESENTATIVE OF THE COMPANY HAS ANY AUTHORITY TO EXTEND OR MODIFY THIS WARRANTY UNLESS SUCH EXTENSION OR MODIFICATION IS MADE IN WRITING BY A CORPORATE OFFICER.
Some states/provinces do not allow the exclusion or limitation of incidental or consequential damages and some states/provinces do not allow limitations on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state or province to province. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE/PROVINCIAL LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF MANUFACTURE.
Effective: May 1, 2013. This warranty applies to all Products purchased after this date.

Need help?
Go to our website or contact us.
Watts.com 
radiant@wattswater.com 
1-800-276-2419
IOM-W561 2233
USA: T: 800-276-2419 · Watts.com
Canada: T: 888-208-8927 · Watts.ca
Latin America: T: (52) 55-4122-0138 · Watts.com
81021177 © 2022 Watts