Litedeer Homes ZEF38VC 38 Inch Smart Electric Fireplace Owner’s Manual
- June 15, 2024
- Litedeer Homes
Table of Contents
Litedeer Homes ZEF38VC 38 Inch Smart Electric Fireplace
PRODUCT INFORMATION
Model : ZEF38VC
Specifications
ELECTRICAL CONNECTION REQUIREMENTS
-
Circuit
15 AMP, 120V/60Hz -
Connection Method
Plug-in /Hardwire -
BTus
5,000 -
Watts
750/1500
FRAMING WIDTH A| FRAMING HEIGHT B| FRAMING DEPTH C| FRAMING
WIDTH D| FRAMING DEPTH E| FRAMING DEPTH F
---|---|---|---|---|---
30″
(763 mm)
| 215/8″
(550 mm)
| 8″
(203 mm)
| 38″
(966 mm)
| 26 7/8″
(684 mm)
| 30″
(763 mm)
IMPORTANT SAFETY INFORMATION:
Always read this manual first before attempting to install it. For your
safety, always comply with all warnings and safety instructions contained in
this manual to prevent personal injury or property damage
Installation
WARNING : ANY INSTALLATION AND SERVICE WORK CAN ONLY BE PERFORMED BY QUALIFIED AND AUTHORIZED PERSONNEL. ALL INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES AND LAWS, AND INSPECTED AND APPROVED FOR OPERATION BY THE LOCAL GOVERNING AUTHORITY BEFORE USE.
WARNING :
Construction and electrical outlet wiring must comply with local building
codes and other applicable regulations to reduce the risk of fire, electric
shock, and injury to persons. To position the Latitude, the Gloria & Marie
Series uses Visual-X Flame Technology, designed to achieve the best results
when the ambient light level is low. If the Unit is installed in a bright
area, strong reflections may weaken the flame. According to your specific
application, it is very important to install the device at a height suitable
for the audience to appreciate. It is recommended to use the following
guidelines to locate the device.
NOTE : Measurements are to the bottom of the viewing area of the flame.
For standing applications:
- Minimum – 26″ (66.0 cm)
- Maximum – 51″ {129.5 cm)
For sitting applications:
- Minimum – 26″ (66.0 cm)
- Maximum – 36″ {91.4 cm)
Plug-In Installation
You may run the power cord out of the framed wall opening to an existing
outlet or install an outlet on a nearby wall stud within the wall. If the cord
is not long enough to reach the outlet, a grounded extension cord with minimum
AWG No. 14 wiring and rated to a minimum oof1875 watts may be used.
Hardwire Installation
The Latitude, Gloria & Marie are supplied in an assembled state and are
designed to be permanently installed. The unit comes ready for plug-in
installation.
WARNING : Do not attempt to wire your new outlets or circuits. To reduce the risk of fire, electric shock, or injury to persons, always use a licensed electrician.
WARNING : Ensure that the On/Off switch is set to the Off position (refer to Operation section) and that the circuit on which the Unit is to be installed has the power cut off at the service panel until installation is complete.
NOTE : Please read all instructions before installing.
Framing and installation
For rough framing, the opening should follow the recommended dimensions located in Figure 1.
NOTE : Dimensions provided are minimum clearances and will vary depending
on the type of support framing and finishing options.
NOTE : Framing should be constructed to support: ZEF38VC-II {22KG/45Lbs)
Framing Dimensions
Recommend Frame size
For more information, please visit: www.litedeerhomes.com
Installation Steps:
- Make sure that the main power switch is turned off, and then plug the power plug into the wall socket, place the fireplace into wall framing, and use framing screws to secure the side brackets to the wall (see Figure 2)
- After placing the fireplace in the correct position, use the 8 screws provided with the fireplace to fix it to the wooden frame one by one to ensure that it is tightly locked.
- After finishing the above work, the next step is to loosen and remove the two screws that lock the outer frame, then take out the front trim piece. (see Figure 4)
- Loosen and remove the hinge plate behind the top trim. remove the two screws of the baffle bar on the inclined glass and remove the inclined glass. See fFigure5.
- First, place natural pebbles on the bottom, and then put the driftwood log sets on the ember bed. (see Figure 6)
- When the ember bed decoration is complete. The first operation step is to put the glass back in place, Lock the hinge plate, and fix the outer metal frame (see Figure 7). Reinstallation is just the opposite of the disassembly steps above.
Grounding instructions
This heater is suitable for 120 volts. The power cord has a plug, as shown in A, this is a highly recommended configuration. If you want to use an adapter, as shown in Figure C, make sure that the adapter can be used to connect the three-prong grounding type plug into a two-slot socket. green ground lug extending from the adapter must be connected to a permanent ground, such as a properly grounded outlet box.
When properly installed, it provides a ground connection through the cord to the heater to protect the operator from electric shock.
Schematic diagram
Litestar Smart Electric Fireplace Insert -ZEF38VC
Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision.
In the Canada 11151 Bridgeport #1718 Richmond, BC V6X 1T3
Read User Manual Online (PDF format)