DIEHL Hydrus Ultrasonic Meter Owner’s Manual
- July 14, 2024
- DIEHL
Table of Contents
DIEHL Hydrus Ultrasonic Meter
APPLICATION
Highly accurate, lead-free brass ultrasonic smart water meter for residential,
commercial and industrial installations.
FEATURES
- Extreme low-flow accuracy and long term measurement stability
- Integrated leak detection
- Mountable in any installation position
- Lead-free copper alloy body
- IP68 rated
- 42 days of hourly data storage
- Diehl Extended Encoder protocol that includes temperature, alarms and error messages, etc.
- Meets or exceeds C715 AWWA/ANSI Standards
- Complies with NSF/ANSI Standards 61, Annex F/G as well as FCC part 15 B
GENERAL TECHNICAL DATA
HYDRUS
- Potable water temperature °F 33 … 122
- Ambient operating temperature °F -13 … 131
- Ambient storage temperature °F -13 … 158 (90° F max. for one hour)
- Maximum operating pressure psi 300
- Power supply Two 3.6 VDC lithium batteries
- Battery lifetime Up to 20 years
- Encoder interface 9 digit programmable resolution industry standard encoder protocol, ASCII output for compatibility with most AMR/AMI systems, Diehl extended protocol is available
- Data storage Alarms and consumption values (42 days of hourly data storage)
- Protection class IP68
TECHNICAL DATA DISPLAY
-
Display indication LCD, 9-digit, additional symbols/display counter/unit
-
Units Flow and volume (gpm, gal, ft³, m³)
-
Values displayed
Display test – total volume – firmware version / checksum – current flow – errors / alarms (Additional values based on configuration) -
Alarms
Hardware flow – leak detection – backflow – air in pipe – low battery – undersized meter – no consumption – high temperature – freezing risk
APPROVAL
- NSF Complies with NSF/ANSI Standard 61, Annex F/G
- AWWA Meets or exceeds applicable sections of the AWWA/ANSI C715 Standards
- FCC Complies with FCC part 15 B
MATERIAL
- Measuring pipe Lead-free copper alloy (stainless steel 1½” & 2″)
- Register housing Engineered polymer
- Transducers Composite
- Reflectors Stainless steel
TECHNICAL DATA
Size | ⅝” x ½” | ⅝” x ¾” | ¾”S | ¾” | |||
---|---|---|---|---|---|---|---|
Lay length inch | 7½ | 7½ | |||||
7½ | 9 | ||||||
Operating flow range gpm | 0.08 – 22 | 0.08 – | |||||
22 | 0.1 – 32 | 0.1 – 32 | |||||
Low flow range gpm | 0.025 – 0.08 | ||||||
0.025 – 0.08 | 0.04 – 0.1 | 0.04 – 0.1 | |||||
Starting flow gpm | 0.011 | ||||||
0.011 | 0.017 | 0.017 | |||||
Operating range accuracy % | ±1.5 | ±1.5 | |||||
±1.5 | ±1.5 | ||||||
Low flow range accuracy % | ±5 | ±5 | ±5 |
±5
Pressure loss psi| 4.3@15 gpm|
| 4.3@15 gpm| | 2.0@15 gpm| | 2.0@15 gpm
Size| | 1″| | 1 ½”| | 2″|
Lay length inch| | 10¾| |
13| | 17|
Operating flow range gpm| | 0.1 – 55| | 0.16
– 100| | 0.8 – 170|
Low flow range gpm| | 0.055 – 0.1|
| 0.1 – 0.16| | 0.55 – 0.8|
Starting flow gpm| | 0.025| |
0.038| | 0.11|
Operating range accuracy %| | ±1.5| | ±1.5| |
±1.5|
Low flow range accuracy %| | ±5| | ±5| | ±5|
Pressure loss psi| | 1.5@25
gpm| | 3.5@70 gpm| | 3.6@110 gpm|
DIMENSIONS
Size | ⅝” x ½” | ⅝” x ¾” | ¾”S | ¾” | |||||
---|---|---|---|---|---|---|---|---|---|
Lay length | inch | 7½ | 7½ | 7½ | 9 | ||||
Register length | L1 | inch | 3.5 | 3.5 | 3.5 | 3.5 | |||
Register width | W | inch | 3.7 | 3.7 | 3.7 | 3.7 | |||
Overall height | H | inch | 4.0 | 4.0 | 4.0 | 4.0 | |||
Height from center of pipe to top | **** |
H1
| ****
inch
| ****
2.7
| | ****
2.7
| | ****
2.7
| | ****
2.7
Nominal thread size
| | | ¾” – 14
NPSM
| | 1” – 11½ NPSM| | 1” – 11½ NPSM| | 1” – 11½ NPSM
Net weight| | lbs.| 2.8| | 2.8| | 2.8| | 3.1
Size| | | | 1″| | 1 ½”| | 2″|
Lay length| | inch| | 10¾| | 13| | 17|
Register length| L1| inch| | 3.5| | 3.5| | 3.5|
Register width| W| inch| | 3.7| | 3.7| | 3.7|
Overall height| H| inch| | 4.2| | 5.3| | 5.8|
Height from center of pipe to top| ****
H1
| ****
inch
| | ****
2.8
| | ****
3.3
| | ****
3.3
|
Nominal thread size
| | | | 1¼” – 11½ NPSM| | ****
oval flanges
| | ****
oval flanges
|
Net weight| | lbs.| | 3.5| | 14.1| | 19.2|
Diehl Metering LLC, U.S.A ∙ 2200 Western Court, Suite 110 ∙ IL 60532 Lisle ∙
United States of America
Phone: +1331-204-6540
metering-usa-info@diehl.com