Billi Quadra Sparkling Plus Tap option XL Installation Guide
- June 13, 2024
- Billi
Table of Contents
Installation guide
Billi Quadra Sparkling & Quadra Sparkling Plus
Tap option XL
(906060, 906065, 906100, 906105)
Version 11/2021
Quadra Sparkling Plus Tap option X
Installation requirements.
XL
Unpacking your Billi Quadra Sparking Unit Before commencing installation,
carefully check for any damage to outer carton, inner liner, appliance
metalwork, pipework fittings and electrical power cord. If damage is
found,please photograph and record details for use if a claim is to be made.
WARNINGS relating to this appliance must be read before commencing
installation. Refer to page 8.
When unpacking your appliance, ensure you have identified the following
components:
- Boiling water module
- Chilled water module
- CO2 cylinder CO2 regulator
- Dispenser
- Tube spring clamps x 2
- Natural and 2 x black Ø6 mm PE tubes with stem elbows fitted
- Extra 6mm stem elbow fitting
- 600mm flexible braided hose
- Filter cartridge (installed)
- User guide
- Warranty registration card
- Warning label
- Plastic Ø6mm tube cap
- 5mm door spacer pads
- Ventilation grille – cupboard base
Determine Unit Location
Plan the installation carefully, taking into consideration dispenser tube
lengths, position of power and water outlets, ventilation airspace
requirements and access for service. Refer to diagrams 1, 2, 3a, 3b and 4.
Diagram 4 shows minimum clearances required around the units for ventilation
Water Supply
A single cold water supply point with a ½” BSP stop tap is required. Stop tap
is to be installed inan easily accessible position, within 600 mm of the inlet
to the boiling water module. Sparkling chilled water module is supplied from
an outlet fitting on the Boiling water module.
Dynamic supply pressure: Min. 250 kPa, max, 1000 kPa
NOTE: Quadra Plus models require an additional½” BSP stop tap water supply
tap. Refer to instructions on Page 6.
Supply temp: Min. 5°C, max. 30°C
Do not install with water that is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water that may
contain filterable cysts.
Power Requirements
Quadra Sparkling models: 460 and Plus 9 require 2 single or 1 double 10 amp
GPO, installed in an accessible position. Refer to Diagram 1. Quadra Sparkling
models: 4100 and Plus 15 boiling module require a separate 15A GPO with a
dedicated circuit.
Power circuits must be fitted with an earth leakage protection device (RCD).
Both boiling and chilled water module are supplied with a 1 meter flex cord
and plug. Cupboard ventilation fan kits require an extra 10A GPO outlet.
Ventilation Grilles
A ventilation kit including lower cupboard vent grille and 5mm door spacers is
supplied with each Billi Sparkling/Chilled water unit.Separate installation
instructions are provided within the vent kit packaging. For lower usage,
domestic installations, sufficient ventilation may be provided by natural air
movement through the cupboard airspace. Minimum area of lower and upper air
vent openings is 100 cm² IMPORTANT: This Billi appliance
is to be installed by a licensed trades person in accordance with AS/NZS
3500.1 and AS/NZ 3500.2 and in compliance with applicable state regulatory
requirements.For correct operation of this appliance, it is essential to
observe the manufacturer’s instructions.
-
Install Dispenser Assembly
Determine position of dispenser mounting hole in sink top or bench top. Dispenser base template (Diagram 5) may be cut out and used to assist in correct positioning. Refer to Diagram 2 for clearances allowed. Hole size required is ø32mm.
The Billi XL dispenser is supplied with base assembly preassembled into dispenser upper and this must be first removed prior to starting installation. Using allen key supplied in installation kit, remove chrome plated M4 screw from rear of housing. Twist base
casting around 60º and then slide assembly out of upper housing. Carefully pull tubing and electrical cable and plug through base assembly.
—Stainless Steel Sinktop
A suitable 32mm hole punch (Part no: 857901) is available as an accessory from Billi Australia Pty Ltd. If possible, cut hole with die mounted below the sinktop surface so that burr is pulled downwards.
Alternatively, remove burr and radius edge of hole with fine file. This allows barbed dispenser mount to slide smoothly into mounting hole.
—Timber/Laminate Benchtop
Maximum benchtop thickness is 50mm. Cut 32mm hole in appropriate position. When drilling through a particle board bench top, take care to avoid substrate chipping and breaking away as drill breaks through underside surface. We recommend drilling a small pilot hole through benchtop, partially drilling the 32mm hole from underneath and then completing drilling the hole from above.
The large 30mm washer supplied may be used to secure barb where bench top substrate has chipped away.
—Granite/Marble Benchtop
For granite or marble bench tops we recommend that you use a certified stone mason to pre-drill the hole. -
Activate Dispenser Swivel Feature
The XL dispenser can be installed either as locked into straight position or able to swivel 45º in either direction. To activate the swivel feature of your dispenser, remove the locking piece from the dispenser base. Simply push out the piece as show in Diagram 6. This will allow the tap to swivel to the left and right. -
Fit Dispenser Base
a. Cut a 32mm hole in sinktop or benchtop. Remove burr if protruding upwards.
b. Push barbed mounting shaft through mount hole.
c. Insert barb locking bush as shown in Diagram 7. Finger tighten nut.
d. Ensure barb is centred in mount hole before tightening. Check position of base ring and gasket.
e. Moderately tighten locking nut using multigrips or spanner. Take care to avoid overtightening nut which may break the plastic threaded shaft.
f. Place large D washer over thread as shown in Diagram 7. -
Fit Dispenser Head Assembly
a. Feed dispenser tubing and loom through center hole in the following order:
i. Dispenser power cord
ii. Silicone tubes
iii. Blue PE tube.
b. Gently pull hoses from under the bench top. Do not attempt to force tubing through with a pointed object as silicone tube is easily punctured. Check tubing is not kinked or twisted. Refer to Diagram 9.
c. Turn dispenser head assembly to approximately 60° from the straight ahead position of dispenser base. Slide head assembly onto base assembly whilst gently pulling tubing downwards from underneath to prevent tubing bunching and kinking. Head retaining lugs will pass nut and slide down the 3 grooves on the swivel bearing.
d. Once fully down, turn dispenser to straight ahead position. Fit chrome plated M4 retaining screw to lower rear threaded hole and tighten using the allen key supplied. If swivel feature is activated, check dispenser now swivels smoothly 45° in each direction.
![Billi Quadra Sparkling Plus Tap option XL
-
Diagram 5](https://manuals.plus/wp-content/uploads/2023/09/Billi-Quadra- Sparkling-Plus-Tap-option-XL-Diagram-5.jpg)
-
Flush Water Supply
Flush water supply pipework before installing the underbench unit by connecting 600mm flexible braided hose to the supply tap and running water into a bucket. NOTE: Blockages/unit malfunction caused by debris are not covered by warranty. -
Install Underbench Unit
Take care to observe minimum clearances. Refer to Diagram 1 and Diagram 4. Ensure there is adequate clearance for ventilation and service access to the units, considering the tube lengths and space available. -
Connect Dispenser Tubing and Plug
IMPORTANT: Boiling outlet (red), vent tube (grey) must not be kinked and must be installed with a continual fall and no sag.
Connect all tubing and electrical plug as shown in Diagrams 10 and 11.
NOTE: For Quadra Plus 9 and Plus 15 models, refer to installation instructions on page 6 for installing sink mixer tap.
a. Trim silicon tubes to correct lengths using a sharp knife or plastic tube cutter. Avoid leaving excess tubing which will sag and trap water. Fit spring clamps to tubing prior to connecting.
b. Red silicone tube pushes on to boiling module fitting labelled BOILING (RED). Secure with spring clamp supplied.
c. Grey silicone tube pushes on to boiling module fitting labelled VENT (GREY) Secure with spring clamp supplied.
d. Dispenser electrical cable Mini-Din connector plugs into boiling unit socket.
e. 6mm PE tube connections are made using push-fit connectors. There are 3 x Ø6mm tubes supplied loose in your installation kit; 2 x black, and 1 x natural (clear). Each tube has an elbow fitting attached to one end. An additional 6mm elbow is supplied which is to be fitted to the blue dispenser tube once tube has been trimmed to correct length.
f. Tube elbows are inserted into fittings at rear of chiller. Refer to diagram 10 and 11 for correct tube orientation and colour coding. TIP: It is easiest to fit these tubes to chiller before unit is installed. Before inserting tubing into push-fit connectors, ensure that tube ends are cleanly cut and not flattened or kinked. Tube is pushed firmly into connector until properly seated. (To release, press the retaining collet ring inwards while pulling gently on the tube).
g. Connect power lead with 6-way mini din plug from boiling module to socket located at rear RHS of the sparkling water module -refer to diagram 12. Rear mounted plug guide bracket helps to locate socket position and orientate plug correctly. NOTE: At this stage, do not connect CLEAR feed tube between boiling and chilled water modules. This will be connected once ice bank had been filled. Instead, connect the BLACK tube to the ambient water fitting on the boiling module. Refer to diagram 10. -
Connect CO2 bottle and pressure regulator
a. Remove CO2 bottle from packaging box. Remove plastic cap from threaded outlet of bottle.
b. Remove CO2 pressure regulator from packaging and check pressure control knob is turned fully anticlockwise.
c. Holding the CO2 bottle upright, screw the pressure regulator onto outlet. A small amount of CO2 gas will escape until regulator has been tightened.
d. Decide location of CO2 bottle in cupboard space.
e. Black Ø6 mm tube from chiller module connects to outlet of gas regulator. Trim tube to correct length, push into fitting and tighten retaining nut. Refer to diagram 10 & 13.
-
Additional Components for Billi Quadra
Sparkling Plus 9 and Plus 15 Models
Before commencing installation, identify the following components:
-
O-ring (large)
-
Tap base ring
-
Mount clamp (brass)
-
Mount clamp plate gasket
-
Mount thread
-
Extended fixing nut
-
Barb adaptor fitting (short)
-
Barb adaptor fitting (extended) marked ‘TAP-H’
-
Spring hose clamps x 2
-
½” joining nipple
-
1 metre PVC tubing
-
Braided flexible hoses x 3
i. Marked ‘UNIT HOT-IN’
ii. Marked ‘TAP-IN’
iii. Marked ‘TAP-OUT’ -
Mixer Tap
Mixer Tap Mounting Procedure
-
Drill or punch mount hole and deburr.
– Hole size: 35mm.
– Sink or Benchtop thickness: 1 – 45mm. -
Screw in 35mm brass mounting thread into the bottom of the mixer.
-
Insert tap base ring over mounting thread. Ensure it is flush against the tap body with inset O-ring facing down.
-
Screw barb adaptor fitting (extended) marked ‘TAP-H’ into marked ‘H’ threaded hole in base of mixer tap.
-
Insert mixer tap through the mount hole and place tap in correct position with Billi logo facing front.
-
Insert the large O-ring, followed by mount clamp plate gasket. Finally insert the brass mount clamp with 2 locking screws. See Diagram 14.
NOTE: Ensure that the grooves from the mount clamp plate gasket are inserted into the channel of the brass mount clamp. -
Hand tighten the fastening assembly until it is quite firm. Using a philips head screw driver tighten both locking screws until the dispenser is firmly secured. See Diagram 14.
-
Insert braided flexible hose marked ‘TAPOUT’ into marked ‘OUT’ threaded hole into base of mixer tap. Screw in clockwise until tight.
-
Insert braided flexible hose marked ‘TAP-IN’ into marked ‘IN’ threaded hole into base of mixer tap. Screw in clockwise until tight.
-
Push PVC tubing onto barb and fit spring hose clamp. Position hose clamp lugs as shown in Diagram 15.
Connecting Mixer Tap to Quadra Plus
Fit tubing connections as shown in Diagram 16a & 16b.
- Water supply inlet tube marked ‘TAP-IN’ incorporates an inline strainer. Connect to ½” BSP stop tap.
- Fit short barb adaptor to port at the rear of Quadra unit marked ‘Hot Outlet’. Trim PVC tubing to correct length using sharp knife. Excess tubing will cause sagging and possible kinking. Push tube onto barb adaptor and fit spring hose clamp. Support may be needed for PVC tube if there is a horizontal run.
- Fit braided coupling marked ‘UNIT HOT-IN’ to matching port. Join to braided coupling marked ‘TAP-OUT’ using ½” joining nipple.
Operating the Mixer Tap
Operation of the mixer tap is as with any single lever tap. Lift lever to
start water flow. Swing to the left for hot water and to the right for cold
water.
Hot water will not be available until Quadra boiling water tank has filled and
heated Bubbling in the hot water flow indicates insufficient boiling water is
available. Wait a few minutes for tank to fill and heat. ![Billi Quadra Sparkling Plus Tap option XL
- Diagram 11](https://manuals.plus/wp-content/uploads/2023/09/Billi-Quadra- Sparkling-Plus-Tap-option-XL-Diagram-11.jpg)
Commissioning XL
Basic unit operation
Left hand lever dispenses boiling water. Right hand lever dispenses chilled
water. Pressing or lifting both dispenser levers together dispenses sparkling
chilled water. Dispenser levers can be pressed for single cup delivery or
lifted for continuous flow. Levers will latch when lifted and can be released
with a slight touch. Red and blue dispenser lights flash when water is
initially heating and cooling and remain steady on when set temperatures are
reached. Refer to User Guide for further operational instructions
Turn on Water Supply
Remove boiling module front panel. Remove foam packing piece from under filter
canister. Ensure filter is securely locked back into place. Turn on water
supply tap and ensure that there are no leaks.
Turn on power to chilled module
Plug both boiling module power lead and chiller module power lead into power
points. Switch boiling module only on. Do not switch chiller on at this stage.
Boiling unit will begin filling automatically. During the initial fill, red
dispenser LED flashes rapidly. Water level in the hot tank rises until it
reaches the lower level sensor.
Boiling water temperature calibration
NOTE: During hot water calibration mode, cold water delivery is disabled
and chiller module cannot be commissioned until calibration cycle is complete.
Hot water calibration cycle can be aborted by turning the power off and back
on again.
Boiling water module will begin to heat after water level in the tank reaches
the lower level sensor. Hot water temperature calibration cycle begins
automatically. During the calibration cycle, hot water temperature continues
to rise until it begins to boil. The unit will continue to boil for up to 30
seconds while the temperature sensor calibrates.
WARNING: Steam and small amounts of hot water may be discharged from the
tap and vent during this period.
While calibration cycle is operating, the hot water indicator (red) will
double blink rapidly. Once calibration cycle is completed, the unit will
resume normal operations and the calibration data is saved.
Fill Sparkling Chiller Module ice bank
a. Fit black ice bank fill tube from chiller into ‘AMBIENT OUTLET’ fitting on
Boiling Module. Refer to Diagram 10. NOTE: Do not turn on power to chiller at
this stage.
b. Lift cold water lever on dispenser tap. After about 15 seconds, water will
show in the bottom of the sight glass tube. Watch this level rise as water is
fed in.
Note: If ambient water flow stops before ice bank is full, release cold
lever and lift again.
c. Release cold lever when water level reaches the minimum fill marker. Refer
to Diagram 18. If tank is overfilled, disconnect sight glass elbow fitting
from top bulkhead fitting and swing tube downwards and drain required amount
of water. Water level in this tank will rise a little later as an ice bank
forms.
d. Disconnect Ø6 mm black fill tube from boiling module ambient water outlet
fitting. Fit cap supplied in installation kit onto end of tube. Coil and tuck
black tube behind modules for later use.
e. Connect clear Ø6 mm tube from chiller module to the boiling module fitting
labeled ‘AMBIENT OUTLET’.
Chiller set up
a. Ensure Chiller power lead is plugged into power point. Switch power point
on.
b. Ensure chiller module power switch located at rear of module is turned on.
(Diagram 17)
c. Soda water pump starts to run.
d. Lift chilled lever on dispenser and let the water run until it stops
automatically. (60s)
d. Return the chilled lever to the center position.
e. Soda water pump continues to run until soda tank is full.
Set up CO₂ system
a. Screw CO2 cylinder into CO2 regulator and hand tighten. Some gas may escape
during this process. Refer to instruction on pg 5.
b. Open the CO2 regulator by turning the black knob clockwise (Diagram 13)
c. Set the initial pressure to around 4 Bar.
d. Press both tap levers and dispense water and ensure the gas pressure
stabilizes.
NOTE: Water carbonation levels will continue to increase until water in
the soda canister has become chilled and air has been dispelled.
Purging air from the CO₂ system
Air trapped in the soda tank is detrimental to the production of sparkling
water and full carbonation may not be reached until 2-3 days of use. To speed
this process, it is beneficial to purge the tank with CO2 using the following
procedure:
a. Lift both tap levers and allow soda water to flow.
b. Continue to run the tap until the tank is empty and gas flows from the
outlet. Soda water feed pump will continue to run.
c. Release tap levers. Wait until soda water pump stops. Press both tap levers
together and check that water flows.
d. Press cold lever only and check that water flows.
Set Chilled Water Temperature
Set the desired water temperature using temperature control knob. Refer to
Billi User Guide. Chiller refrigeration system will run continuously for
approximately 2 – 3 hours as ice is formed in the ice bank. As a significant
amount of heat is dispelled during this time, it is advisable to leave a
cupboard door ajar during the initial cool down. As ice expands, the water
level in the ice bank tank will rise slightly.
Check water level is within operating range on sight glass level markings.
Water level can be reduced if necessary. See Diagram 18.
NOTE: To drain water from ice tank, disconnect upper sight-glass fitting,
swing tube downwards and drain water into a cup or container.
Adjusting carbonation level
It is advisable to wait for cold water temperature to stabilize and air to be
purged from the sparkling water unit before adjusting the carbonation level.
Initial set point may vary once the unit is running. You may need to adjust
the pressure once the system has stabilized.
A pressure between 3 and 4 Bar will typically provide the right level of
carbonization.
WARNING: CO2 pressure must not exceed 5 bar
Re-check connections for leaks. Explain operation to user.
Commissioning Checklist
CHECK EACH OF THE FOLLOWING ITEMS:
Filter packing foam removed from under filter cannister.
Dispenser mounted securely – M4 chrome retaining screw fitted.
Dispenser swivels 45º in each direction (if activated) – locking piece is
removed.
Tubing is cut to correct lengths and not kinked or sagging. Red and grey
silicone tubes have a continual fall.
Tubing secured correctly – nuts and spring clips fitted.
Water main flushed before connection to unit.
Unit connected to COLD water supply.
Correct air clearances around unit.
Power circuit fitted with an RCD
– earth leakage protection device.
Sawdust cleaned out of cupboard area.
Door vents and spacer pads fitted correctly
Initial program settings correctly set for dispenser tube length.
Unit heating and cooling (after initial fill).
Red and blue dispenser icons flashing (or on continually when reached correct
temperature).
Boiling and chilled water flow correct.
If any difficulties arise contact
Billi Australia Pty Ltd: Phone 1800 812 321 (Free call). Validate your
warranty online at www.billi.com.au
For information on our filtration and service contracts please contact Billi
Customer Service on 1800 812 321 or
service@billi.com.au.
WARNINGS.
For continued safety of this appliance it must be installed, operated and
maintained in accordance with the manufacturer’s instructions. For correct
operation of this appliance, it is essential to observe the instructions as
outlined in this booklet.
— Your appliance should be installed by a suitably qualified tradesperson.
— For correct operation of this appliance it is essential to observe the
instructions as outlined in this booklet.
— Do not use this appliance with water that is microbiologically unsafe or
with water of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
— Filter replacement must be performed at intervals of not more than 12
months.
— Use this appliance only as directed in these instructions and relevant Billi
User Guide and only for its designed purpose.
—Do not install unit if power cord is damaged.
— This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
—Always activate boiling water safety lock switch where children or mentally
disabled persons could access the appliance.
—This appliance is designed for indoor installation only and must not be
exposed to direct sunlight, rain and excessive heat, cold, damp or dust.
—Do not store solvents or corrosive chemicals or other flammable items on or
around this appliance
—DANGER: High Voltages. Power supply must be disconnected before cleaning
or removing and outer covers form the appliance. Any service or unit repairs
must be performed by a trained and suitably qualified technician.
— Children should be supervised to ensure that they do not play with the
appliance.
— DANGER: The operation of the thermal cut-out indicates a possibly
dangerous situation. Do not reset the thermal cut-out until the water heater
has been serviced by a qualified person.
— WARNING: Do not connect any restrictor or pressure relief device to the
vent pipe of this water heater if installed.
— If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
— New hose-sets supplied with the appliance are to be used and old hose-sets
should not be re-used.
—Packaging material including plastic bags must be kept out of reach of
children and disposed of according to local regulations.
—If the appliance has been turned upside down during transport and handling,
wait for at least 8 hours before switching appliance on.
— WARNING: This appliance may deliver water at high temperature. Refer to
the plumbing code of Australia (PCA), local requirements and installation
instructions to determine if additional temperature control is required.
—WARNING: Installation shall conform to the plumbing code of Australia
(PCA).
Designed and manufactured in Australia.
As Billi Australia Pty Ltd has a policy of continual improvement, all details
are subject to change without notice.
All goods are sold subject to our published terms and conditions. Billi is a
registered trademark. 1220
Billi Australia Pty Ltd
42 Lucknow Crescent, Thomastown
Victoria 3074 Australia
Telephone 1800 812 321
www.billi.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>