Technical specifications
Remarks
Water conditions
Prevent damage to your pool lamps and wires due to unstable water conditions.
Your local government may have enacted guidelines for your pool water
conditions to apply by. If not we strongly advise the following parameter
specifications to be applied:
- pH level 6,8 – 7,6
- Free Chlorine max. 3ppm
- Combined chlorine max. 1 ppm
- Water temperature max +40°C and lamps need to be kept out of ice zones
Always adhere to the instructions provided by your chemical brand/supplier for the correct use and application of pool chemicals.
Salt water pools, or pools fitted with a salt water chlorine generator contain
salt in the pool water. Salt is a corrosive material. Overdosage and/or
consistent levels of salt increase the possibility of deterioration of your
pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can
be accepted when pH values are between 7,2-7,4.
In any case, we urge proper use, care and maintenance of your installation, in
order to mini-mize the effect of corrosion and deterioration.
Please be aware that pool lamps and cables with defects caused due to abnormalities in the water condition are not covered by our factory warranty.
Installation/maintenance
The luminaire is maintenance free
If the luminaire needs to be replaced, it needs to be completely removed from
the water
If the external flexible cable or cord of this luminaire is damaged, it shall
be exclusively replaced by the manufacturer or his service agent or a similar
qualified person in order to avoid hazard
VISION Allegro pool lamps must be completely submerged into water during
operation. Fixing the lamps with adhesives or silicone kit into a niche is not
allowed.
Not following these instructions, will void warranty.
Box contents
Lamp type | Connection kit | Cable |
---|---|---|
DVA050 | 513-0480 ; 1 washer for fixnut ; blue cable gasket + 1 spare washer | 1 |
mm2
DVA100| 513-0636 ; 1 washers for fixnut ; orange cable gasket + 1 spare
washer| 1,5 mm2
DVA170| 513-0651 ; 1 washers for fixnut; green cable gasket+ 1 spare washer|
2,5 mm2
Installation instructions
Installing faceplate
Installing connector
Connector installation
Installation specialties
DVA050 & PZA-WG
For installations with DVA050 & PZA-WG-NG:
Please make sure to only use 1 silicone washer for the Fix nut
DVA050 Removal tool
When DVA050 needs to be removed from the PZA-WG-NG wall conduits, a special
tool is needed (513-0491)*
- Insert the tool over the lamp, straight into the wall conduit
- Twist the tool counter clockwise the lamp should be snapped into the 3 hooks of the tool
- Pull the lamp straight out of the wall conduit
Wiring instructions Setup 1
For new installations
Each lamp is connected to the transformer via 1 cable
SELECT
CABLE SECTION & MAXIMUM LENGTH
STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
The transformer VA rating must be greater or equal to the sum of VA ratings of
all connected lamps.
These cable lenghts are calculated with worst case voltage drops in the
electrical wiring.
Wiring instructions Setup 2
For existing or other installations
All lamps are connected to the transformer via 1 cable
SELECT
CABLE SECTION & MAXIMUM LENGTH
Wiring remarks
For installations with LINK Controller or LINK Master
Third party equipment such as frequency inverters and electric motors can
generate excessive noise on the 230VAC / 400VAC power line.
This noise might be injected into the adjacent 12VAC power line and disturb
the power line communication towards the VISION Allegro lights.
To prevent this, please take care of the following:
Keep 230VAC / 400VAC power line cables at least 50cm separated over their full
length from the 12VAC power line towards any lights
Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable
trays
() Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable trays**
Synchronizing
*With LinkTouch
+ LINK Controller (PLP-REM or PLP-REM-350)
+ LINK Master (DLM450 or DLM600)
**
First make sure the LinkTouch is paired (see manual LinkTouch)
Turn the lamps on and spin the color wheel on the LinkTouch until the lamps
react.
If the lamps do not react, turn them off and back on untill they react to the
color wheel. As soon as the lamps follow the color wheel: wait 1 minute. The
lamps are now synced.
*With Transmitter
+ LINK Controller (PLP-REM or PLP-REM-350)
**
Turn the lamps on and push the UP button 10 times. Wait for 20 seconds, then turn the lamps off. Repeat this process until the lamps react to the remote. As soon as the lamps follow the remote: wait 1 minute. The lamps are now synced.
Manual synchronization (without DURALINK control products)
- Switch ON the 12 VAC line voltage and make sure that all lamps light up.
- Switch OFF the 12 VAC line voltage and wait for at least 1 minute
- Switch ON
- The lamps should now all be on color program 1: Blue
Color programs
*all color programs are dimmable if LINK Touch, LINK Contr oller or LINK Master are used (in PLC mode)
Troubleshooting
Declaraction of Conformity
Declarations of conformity covering this product are available for download
from the House of Duratech website: www.duratech.be
Contact details
Propulsion Systems bv Dooren 72
1785 Merchtem, Belgium
Tel +32 2 461 02 53
www.duratech.be
info@propulsionsystems.be
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>