ZKTeco EX0808 I-O Board for US-inBio-Pro Panels User Guide

June 3, 2024
ZKTECO

ZKTeco EX0808 I-O Board for US-inBio-Pro Panels User Guide

Product PIN Diagram

EX0S0S is an extended module for controllers which is used for connecting more number of auxiliary devices.

Product PIN Diagram

No. Name Functions
1 RS485 In Used for RS485 communication.
2 RS485 Out Used to connect an other EX0808 expansion board.
3 Aux Out put Used to connect upto 8 auxiliary output devices.
4 Aux Input Used to connect upto 8 auxiliary input devices.
5 Power Input DC12V-3A.
6 DIP Switch Sets the RS485/OSDP address of the EX0808 and set the

RS485/0SDP communication etc.
7| DIP Switch Instructions| Introduces the use of DIP switches.
8| RUN lndicato r(Green)| Indicates the running stat es.
9| COMM lndicator(Yellow)| Indicates the communication states of the RS485.

LED Status Indicator

RUN Indicator (Green)| | Flashing Green LED Continuously indicates that the device is running normally.
---|---|---
COMM Indciator (Yellow)|

| Flashing Yellow LED Continuously indicates that the device is online and communicating.
| So lid Yellow LED indicates that the device is offline (after 10 seconds of communication fai lure) and communication failed .
| Solid Yellow LED when the device is powered on.

DIP Switch Setting for RS485/OSDP Communication

DIP Switch Setting

Notes:

There are six DIP switches on the EX0808 expansion board and their functions are:

  1. Switches 1 to 4 are used to set the RS485/OSDP addresses.
  2. Switch 5 is for RS485/OSDP mode switchi When set to OFF, RS485 mode is used, and when set to ON , OSDP mode is used.
  3. If the cable length is more than 200 meters, the switch 6 should be ON for noise reduction on long RS485 cables.

Connecting to the Controller

Use the so ftware after connecting th e EX0S0S module to the controller.The EX0S0S module can be connected to the inBioX60 Pro Series. The connection with inBio460 Pro is shown as an example below:

Connecting to the Controller

Notes:

  1. A maximum of eight EX0S0S ext ended boards can be connected to aninBio 460 Pro controller.
  2. Each EX0S0S can connect a maximum of eight auxiliary input devices and eight auxiliary output devices.
  3. A separate power supply is required for each EX0808.
  4. Set the R5485/OSDP addresses of each EX0S0S by the DIP switch before power is supplied.

Connecting to ZKBioSecurityV5000 Software

After wiring, please follow the below steps:

  1. Add inBio460 Pro controller on the
    a. Login to ZKBioSecurityVS000 software and click on Access > Device> Device> Search, to search the device on the software. The searched devices are displayed automatically.
    Connecting
    b. First, change the IP address of the device by clicking Modify IP Then a new window will pop-up, enter the relevant information and click OK.
    Device Name:Enter new IP address.
    New Server Address: Enter the IP address ofthe server (PC).
    New Server Port:The current system communication port (prompt under the search page).
    C. Click Add to add the device on the software.
    Note: The IP addresses of the server (PC) and the device must be in the same network segment.

  2. Add the EX0808 on the software:
    Click Access> Device> 1/0 Board> New to add the EX0808 on the software. Enter the name and RS485/OSDP address of the EX0808.Set the RS485/OSDP address of the EX0808 from1-15.
    Then click OK to save and exit.
    Connecting

  3. On the software, click Access > Device> Auxiliary Input/ Auxiliary Output to view all the auxiliary inputs/ outputs.
    Connecting

Operating Via the Software

  1. Remote operation
    a. On the software, click Access> Device> Auxiliary Output to view\ all the auxiliary outputs.
    b. Select the auxiliary output and clickRemoteOpen,a new window will pop-up.
    c. Enter the relevant information and click Start. You will be able to remotely open the device connected to the auxiliary output via software.
    Operating Via the Software

  2. Linkagefunction
    On the software, click Access > Access Control > Linkage > New and fill in all the relevant information to set a new linkage operation. The operation is as follows:
    a. First, select an auxiliary device on the list and click Device to choose.
    b. Click Add to add the link age trigger condition from drop-down and select the input point on the list.
    c. Set the output point of the Door and the Auxiliary Output.
    d. Select action type and set the action time delay then click OK to save and exit.
    Operating Via the SoftwareFor more details, please refer to the ZKBioSecurityVS000 User Manual.

ZKTeco Industrial Park, No. 32, Industrial Road

Tangxia Town, Dongguan, China.

Phone: +86 769-82109991
Fax: +86 755 – 89602394

www.zkteco.com

Copyright © 2021 ZKTECO CO., LTD. All Rights Reserved.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals